Welcome to our new website, found an issue or bug? Please report it here

LCJA
Heavy Duty, Shear Beam with Corrosion Resistance
Models In Stock
- IP67 Environmental Rating
- Corrosion Resistant
- Calibration Certificate Supplied
- 0.25% Interchangeable
LCJA
From
C$
804.82
Models In Stock

Product Overview
- Bridge Resistance 350 Ω
- Cable Length 20 ft
- Calibration Option NIST
- Electrical Connection Cable
- Hysteresis ± 0.02%
- Interchangeability 0.0025
- Load Cell Type Bending Beam
- Operating Temperature, Max 66 °C
- Operating Temperature, Min -18 °C
- Overload, Max 200% FS
- Process Temperature, Max 66 °C
- Process Temperature, Min -18 °C
- Repeatability ± 0.01%
- Supply Voltage 10 to 15 Vdc
- Thermal Span Effect 0.0008% rdg/°F
- Thermal Zero Effect 0.0015% FS/°F
- Wire Gauge 22 AWG
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error ± 1%
SPECIFICATIONS
Rated Output: 3 mV/V ± 0.0075 mV/V (actual output supplied with each load cell)
Excitation: 10 Vdc (15 Vdc maximum)
Accuracy: ± 0.037% Full Scale
Linearity: ± 0.03% FS
Hysteresis: ± 0.02% FS
Repeatability: ± 0.01% FS
Zero Balance: ± 1% FS
Creep In 20 min: ± 0.03% FS
Operating Temperature: 0 to 150°F (-18 to 66°C)
Compensated Temperature: 0 to 150°F (-18 to 66°C)
Thermal effects: Zero - 0.0015% FS/°F Span - 0.0008% RDG/°F
Maximum Load: 200% FS
Side Load Rejection: 500:1
Bridge Resistance: 350 Ohms nominal
Full Scale Deflection: 0.015 in to 0.025 in
Construction: Nickel Plated Steel
Cable: 20 ft 4-conductor shielded 22-gage wire
Rated Output: 3 mV/V ± 0.0075 mV/V (actual output supplied with each load cell)
Excitation: 10 Vdc (15 Vdc maximum)
Accuracy: ± 0.037% Full Scale
Linearity: ± 0.03% FS
Hysteresis: ± 0.02% FS
Repeatability: ± 0.01% FS
Zero Balance: ± 1% FS
Creep In 20 min: ± 0.03% FS
Operating Temperature: 0 to 150°F (-18 to 66°C)
Compensated Temperature: 0 to 150°F (-18 to 66°C)
Thermal effects: Zero - 0.0015% FS/°F Span - 0.0008% RDG/°F
Maximum Load: 200% FS
Side Load Rejection: 500:1
Bridge Resistance: 350 Ohms nominal
Full Scale Deflection: 0.015 in to 0.025 in
Construction: Nickel Plated Steel
Cable: 20 ft 4-conductor shielded 22-gage wire
Show Ratings & Reviews
For what applications LCJA-Heavy Duty Shear Beam Load Cells can be used? What is the typical working environment?
The LCJA would be used in applications such a tank weighing applications. Their IP67 environmental rating makes them ideal for use in outdoor application or where frequent washdown of equipment is required.
Date published: 2019-11-20
Can I pass a bolt completely through an LCJA load cell at the partially threaded hole?
Thank you for your inquiry, Yes the hole goes all the way through. Please see Datasheet for dimensions
Date published: 2021-12-16
Which side is facing up when mounted? Spec sheet illustration is a little different than the product I received.
Hello, the product itself is symmetrical and should give you a mV output no matter what side is facing up. If you could send us a picture of your load cell to pressure@omega.com we can mark up the mounting side and send it back to you.
Date published: 2023-03-24