1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback
CND3-Series
1/16, 1/8, and 1/4 DIN Temperature and Process PID Controllers
Models In Stock
- Base Model Starting from $80
- Fast Sampling Time 0.1 sec
- Heater Disconnection Detection
- All 1/4, 1/8, 1/16 DIN Models UL/cUL Certified
CND3-Series
From
$
253.62
Models In Stock

Product Overview
- Altitude,Max 2000 m
- Control Mode PID Control, Fuzzy Control, Self-tune, Manual tuning, On-off control
- Display Type Note LCD display. Process value (PV): Yellow color, Set point (SV): Green color, 3.5 Digit Dual Display Display Accuracy: 0 or 1 digit to the right of the decimal point (selectable)
- Input Type Thermocouple, RTD, mA, Voltage
- Measurement Type Current, Temperature, Voltage
- Measuring Range Type K: -200 ~ 1300°C, Type J: -100 ~ 1200°C, Type T: -200 ~ 400°C, Type E: 0 ~ 600°C, Type N: -200 ~ 1300°C, Type R: 0 ~ 1700°C, Type S: 0 ~ 1700°C , Type B: 100 ~ 1800°C, Type L: -200 ~ 850°C, Type U: -200 ~ 500°C, Type TXK: -200 ~ 800°C, RTD (JPt100): -20 ~ 400°C, RTD (Pt100): -200 ~ 850°C, Resistance (Ni120): -80 ~ 300°C, Resistance (Cu50): -50 ~ 150°C, Analog Voltage Input (0~5V): -999~9999, Analog Voltage Input (0~10V): -999~9999, Analog Voltage Input (0~20m A): -999~9999, Analog Voltage Input (4~20m A): -999~9999, Analog Voltage Input (0~50m V): -999~9999
- Number of Inputs 1
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Output Signal None
- Ramp and Soak Multiple Ramp & Soak
- Relative Humidity 35% ~ 80% RH(non-condensing)
- RTD Type 100 Ω pt or Jpt sensor; 3-wire Pt100
- Sampling Rate 10 Hz (10 updates/second)
- Sampling Rate Note Analog input: 0.1 sec/scan; Thermocouple or Platinum RTD: 0.1 sec/per scan
- Shock Resistance Max. 300m/ s² , 3 times in each 3 axes, 6 directions
- Storage Temperature, Max 65 °C
- Storage Temperature, Min -20 °C
- Supply Power Note 80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ± 10%; 24 Vdc ± 10%
- Thermocouple Type J, K, T, E, N, R, S, B, L, U, TXK
- Vibration Resistance 10 to 55Hz, 10m/s² for 10min, each in X, Y and Z directions
The New Omega temperature & process controller CND3 Series is designed with upgraded hardware and higher specifications to offer smart operation, fast response, and easy to use, plus user-friendly and user-defined function keys. With Self-Tuning PID and FUZZY temperature control functions, controllers can be installed in both open space or confined space applications and are capable of presenting a smooth temperature control curve.
Applications Include: Machinery for the printing, food packaging, solar panel manufacturing, and high-tech electronics industries.
SPECIFICATION
GENERAL SPECIFICATIONS
Power:
AC Power: 100 to 240 VAC, 50/60Hz, 5VA max
DC Power: 24 VDC ± 10%, 5W max
Display: 2 line by 4-digital, FSTN LCD negative image transmissive with backlight
PV Display: Orange color backlight
SV Display: Green color backlight
Certification and Compliances:
Safety: UL Recognized Component, File E243710 Vol. 1
EC Declaration LVD: EN61010-1; 2010
EMC: EN61326-1; 2013, EN61131-2; 2007, EN61000-6; 2005, EN61000-6-4; 2007/A1; 2011 IP66 Enclosure rating (face only), IEC60529 Edition 2.1 2001-02
INPUT SPECIFICATIONS
Sample Rate: 100ms
Sensor Input Overvoltage Rating: 15 Vdc
RTD Inputs
Type: 3 wires
Excitation: 180µA
Lead Resistance: 15OΩ max per wire
Resolution: 1 or 0.1ºC for all type
Thermocouple
Input Impedance: Approx. 4.7MΩ
Lead Resistance Effect: -0.3µV/Ω
Cold Junction Compensation: Less than 1.5ºC typical (max 2.0ºC) error over -10 to 50ºC ambient temperature range
Resolution: 1 or 0.1ºC for all type
Temperature Indication Accuracy:
± (0.3% of span, +1ºC) at 25ºC ambient after 20 minutes warm up. Including NIST conformity, cold junction effect, A/D conversion errors and linearization conformity
Process Indication Accuracy

*Depending on the rating of resistor 249Ω built in.
Remote Set-Point Input:
DC 0 to 10V Linear Voltage Input: Opening Jumper, resolution: 156µV/scale
DC4 20mA/0 to 20mA Input: Shorting Jumper, resolution: 0.63µA/scale
User Input: (Event Input)
Contact:
ON Resistance: 1KΩ Max.
OFF Resistance: 100KΩ Min.
Response Time: 1 sec.
CT Input:
Opening Jumper for Max 30A Measurement with 30A CT Ring, Resolution: 0.1A
Shorting Jumper for Max 100A Measurement with 100A CT Ring, Resolution: 0.1A
OUTPUT SPECIFICATIONS
Relay Output:
Type: Form A
Contact Rating: 5A @ 250 VAC or 30 VDC (Resistive Loading)
Pulse Voltage Output:
Rating: DC 12V ± 10%, 40mA max with short protection.
Current Output:
DC 0 to 20mA/DC 4 to 20mA output, max resistive loading 500Ω
Resolution: 2.14µA/scale
Linear Voltage Output:
DC 0 to 10V Output, min Resistive Loading 1KΩ Resolution: 1.1mV/scale
Retransmission Output
DC 0 to 20mA/DC 4 to 20mA Output, Max Resistive Loading 500Ω Resolution: 2.09µA/scale
Read More
Applications Include: Machinery for the printing, food packaging, solar panel manufacturing, and high-tech electronics industries.
SPECIFICATION
GENERAL SPECIFICATIONS
Power:
AC Power: 100 to 240 VAC, 50/60Hz, 5VA max
DC Power: 24 VDC ± 10%, 5W max
Display: 2 line by 4-digital, FSTN LCD negative image transmissive with backlight
PV Display: Orange color backlight
SV Display: Green color backlight
Certification and Compliances:
Safety: UL Recognized Component, File E243710 Vol. 1
EC Declaration LVD: EN61010-1; 2010
EMC: EN61326-1; 2013, EN61131-2; 2007, EN61000-6; 2005, EN61000-6-4; 2007/A1; 2011 IP66 Enclosure rating (face only), IEC60529 Edition 2.1 2001-02
INPUT SPECIFICATIONS
Sample Rate: 100ms
Sensor Input Overvoltage Rating: 15 Vdc
RTD Inputs
Type: 3 wires
Excitation: 180µA
Lead Resistance: 15OΩ max per wire
Resolution: 1 or 0.1ºC for all type
Thermocouple
Input Impedance: Approx. 4.7MΩ
Lead Resistance Effect: -0.3µV/Ω
Cold Junction Compensation: Less than 1.5ºC typical (max 2.0ºC) error over -10 to 50ºC ambient temperature range
Resolution: 1 or 0.1ºC for all type
Temperature Indication Accuracy:
± (0.3% of span, +1ºC) at 25ºC ambient after 20 minutes warm up. Including NIST conformity, cold junction effect, A/D conversion errors and linearization conformity
Process Indication Accuracy

*Depending on the rating of resistor 249Ω built in.
Remote Set-Point Input:
DC 0 to 10V Linear Voltage Input: Opening Jumper, resolution: 156µV/scale
DC4 20mA/0 to 20mA Input: Shorting Jumper, resolution: 0.63µA/scale
User Input: (Event Input)
Contact:
ON Resistance: 1KΩ Max.
OFF Resistance: 100KΩ Min.
Response Time: 1 sec.
CT Input:
Opening Jumper for Max 30A Measurement with 30A CT Ring, Resolution: 0.1A
Shorting Jumper for Max 100A Measurement with 100A CT Ring, Resolution: 0.1A
OUTPUT SPECIFICATIONS
Relay Output:
Type: Form A
Contact Rating: 5A @ 250 VAC or 30 VDC (Resistive Loading)
Pulse Voltage Output:
Rating: DC 12V ± 10%, 40mA max with short protection.
Current Output:
DC 0 to 20mA/DC 4 to 20mA output, max resistive loading 500Ω
Resolution: 2.14µA/scale
Linear Voltage Output:
DC 0 to 10V Output, min Resistive Loading 1KΩ Resolution: 1.1mV/scale
Retransmission Output
DC 0 to 20mA/DC 4 to 20mA Output, Max Resistive Loading 500Ω Resolution: 2.09µA/scale
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews