Product Specs
<< See all Product ModelsBrand |
![]() |
5-Point Calibration | 0%, 50%, 100%, 50%, 0% |
Accuracy | ± 0.25 % |
Cable Length | 5 ft |
Calibration Option | 5 POINT NIST |
Electrical Connection | Cable |
Electrical Output | 2 mV/V |
Enclosure Ratings | IP65 |
Force Type | Compression, Tension |
Height | 1.75 in |
Hysteresis | ± 0.25% |
Input Resistance | 360 Ω min |
Linearity | ± 0.25% |
Load Cell Capacity | 2000 lbF |
Load Cell Type | In-line |
Materials | Stainless Steel |
Operating Temperature, Max | 121 °C |
Operating Temperature, Min | -54 °C |
Outer Diameter | 1 in |
Output Resistance | 350 ± 10 Ω |
Overload, Max | 300% FS |
Process Temperature, Max | 71 °C |
Process Temperature, Min | 16 °C |
Repeatability | ± 0.25% |
Safe Overload | 150% FS |
Supply Power Note | 10 Vdc, 15 Vdc maximum |
Supply Voltage | 10 Vdc |
Thermal Span Effect | 0.009% FSO/°C |
Thermal Zero Effect | 0.009% FSO/°C |
Wiring/Connector Table | Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input |
Zero/Balance Error | ± 2% |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
justinraade from
reliable data
The unit is functioning well and producing good data on tension. I'm happy with the purchase.
Date published: 2016-11-14
Rated 5 out of
5
by
KimH from
Cable
Cable works as expected. Pricing was good. Delivery was timely.
Date published: 2024-01-23
Rated 3 out of
5
by
James P from
The Omega 2000 lbf load cell is too tiny.
We never used the Omega 2000 lbf load cell. It looked too small to hold-up to 2000 lbf with the gorillas that work on our system. We went with a more robust larger load cell instead that could stand more unintentional abuse. The typical load is ~ 700 lbf, however, someone could overload it by accident. If the load cell failed and the load dropped, I would never hear the end of it.
Date published: 2023-08-14
Rated 5 out of
5
by
Sidd from
Easy Setup
It was easily set up with the DPS20-LV and initial testing seems to have went well.
Date published: 2023-03-06