Welcome to our new website, found an issue or bug? Please report it here

CT5100-Series
1 or 2 Channel Programmable Process Input Circular Recorders
Models In Stock
- 254 mm (10') Chart
- 1- or 2-Pen Versions,
- Thermocouple, RTD, dc Current, or Voltage Input
- Programmable Inputs
CT5100-Series
From
$
2,256.98
Models In Stock

Product Overview
- Accuracy ± 0.5 %
- Accuracy Note Chart Recording: 0.5% of chart span reference accuracy, Chart Rotation: ±0.5% of rotation time, assuming all backlash removed, Chart Rotation: ±0.5%, Chart Speed: ±1%
- Approvals Note Safety: UL Approved for USA:UL 1092, UL 916 and QUXY, pending UL Certified for Canada:CSA Spec 142, pending Limit/Device: FM, pending
- Chart Diameter 254 mm
- Chart Note Chart Span: Bottom and top of span, -9999 to 9999 units; Chart Drive: DC Stepper Motor; Chart Drive: Stepper Motor
- CMRR >120 dB @ 50/60 Hz, 260 Vac max
- Cold Junction Compensation 0.04°/°C deviation from 25°C
- Conduit Entrance 3 Openings on the Right Side
- Current Measurement Range 0 to 20 mA
- Cutout Dimensions 322.58 x 322.58 mm
- Data protection EEPROM Storage
- Display Note 4-digit, 14 mm H (0.56"), red, 7-segment, LED display, Display Modes: Normal: process value(s) or blank Keypad: 3 keys for programming and unit operation
- Display Type LED
- Enclosure Ratings IP54, NEMA Type 3
- Height 355.6 mm
- Impedance Input >100 MΩ for T/C and mV inputs, 100 kΩ for 5 V inputs, 4.7 Ω for µA inputs
- Input Note Input Correction: Offset adjustment: 999 to 999 units;Input Isolation: 350 Vac, 500 Vdc
- LED Indicators 5 Red LED Alarm Status Indicators, 1 green LED pen 2 indicator
- Length 96.5 mm
- Materials Noryl, Acrylic
- Measurement Range Note Thermocouple: J: 0 to 760°C, K: 0 to 1360°C, T: -200 to 400°C, R: 200 to 1650°C, S: 200 to 1650°C RTD: -140 to 400°C Current: 0 to 20 mA, 4 to 20 mA Voltage: 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
- Measurement Type Thermocouple, RTD, Current, Voltage
- Mounting Panel Mount or Wall Mounting
- NMRR 85 db @ 60 Hz or greater
- Operating Environment Reference Operating Condition: 25 °C
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Panel Depth 64 mm
- Panel Protrusion 33 mm
- Pen Type Disposable Fiber tip
- Power Consumption 18 VA
- Relative Humidity 10 to 90% RH, non-condensing
- RTD Type 100 Ω Pt sensor; α= 0.00385
- Sampling Rate 1 Scan per second for Non-RTD inputs; 1 Scan per 1.2 seconds for RTD inputs
- Sensor Input Configuration 150 µA
- Standard Limits of Error Error Limit: Cold-Junction Compensation Error: ±0.2°C @ 25°C, Linearization Error: T/Cs: ±0.25°C typical, ±0.5°C worst case , RTDs: ±0.1°C typical, ±0.3°C worst case, Ambient Temperature Error: ±0.01% of span per °C deviation from 25°C; Measurement Error: Type J, K, T, R, S and RTD: ±0.25% of span ±1 degree; mA, mV and Vdc: ±0.25% of scaled span plus 1 leastsignificant digit
- Storage Temperature, Max 65 °C
- Storage Temperature, Min -40 °C
- Supply Power Note Line Voltage: 90/264 Vac, 50/60 Hz; optional: 20 to 50 Vac, 50/60 Hz, or 22 to 65 Vdc
- Supply Power Type AC
- Supply Voltage 90 to 264 Vac
- Switch Rating 5 A @ 115 Vac
- Switch Rating Note Relays: SPDT; contacts rated 5 A resistive @ 115 Vac,2.5 A resistive @ 230 Vac, 1⁄8 hp @ 230 Vac (single phase),250 VA @ 115/230 Vac
- Switch Type SPDT NO/NC, Selectable
- Temperature Measurement Range J: 0 to 760°C, K: 0 to 1360°C, T: -200 to 400°C, R: 200 to 1650°C, S: 200 to 1650°C, RTD: -140 to 400°C
- Thermocouple Type J, K, T, R, S
- Voltage Measurement Range 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
- Weight 8.8 kg
- Width 355.6 mm
- Wire Code Option 2- or 3- Wire
CT5100 Series Circular Chart Recorders measure and display up to two process variables. Choose from a variety of programmable inputs. All recorder and alarm functions are easily configured via front 3-key pad with self prompting displays. Total panel depth of only 2.5" is required with only a 1.3" protrusion from the front of the panel.
PDFs & Manuals
Show Ratings & Reviews
Rated 4 out of
5
by
FRANK RENTERIA from
USER FRIENDLY
WE HAVE HAD THESE FOR A FEW YEARS . TWELVE OF THEM THROUGH OUT THE PLANT
THEY HAVE WARE AND TEAR, SO WE NEED A PART BREAK DOWN AND SERVICE MANUEL .I AM TOLD THEY IS NONE. WHY?
Date published: 2017-07-31
Hi, i bought the CT5100 due to power surge the power board burn. Do you supply sparepart for this model?
Thank you for your inquire
Please email the temperature group to see pricing, Leadtime
Temp@omega.com
Date published: 2021-09-10
Does Omega offer a chart temp recorder with 100 ohm RTD and NEMA -3 enclosure designed for outdoor use?
Hi Mike76
Thank you for the inquiry. We do not offer chart recorder designed for outdoor use.
Best regards
OMEGA
Date published: 2021-03-24