Models In Stock
  • 254 mm (10') Chart
  • 1- or 2-Pen Versions,
  • Thermocouple, RTD, dc Current, or Voltage Input
  • Programmable Inputs
CT5100-Series
From $ 2,256.98
Models In Stock
1 or 2 Channel Programmable Process Input Circular Recorders CT5100-Series CT5100-Series
loading all models
Product Overview
  • Accuracy ± 0.5 %
  • Accuracy Note Chart Recording: 0.5% of chart span reference accuracy, Chart Rotation: ±0.5% of rotation time, assuming all backlash removed, Chart Rotation: ±0.5%, Chart Speed: ±1%
  • Approvals Note Safety: UL Approved for USA:UL 1092, UL 916 and QUXY, pending UL Certified for Canada:CSA Spec 142, pending Limit/Device: FM, pending
  • Chart Diameter 254 mm
  • Chart Note Chart Span: Bottom and top of span, -9999 to 9999 units; Chart Drive: DC Stepper Motor; Chart Drive: Stepper Motor
  • CMRR >120 dB @ 50/60 Hz, 260 Vac max
  • Cold Junction Compensation 0.04°/°C deviation from 25°C
  • Conduit Entrance 3 Openings on the Right Side
  • Current Measurement Range 0 to 20 mA
  • Cutout Dimensions 322.58 x 322.58 mm
  • Data protection EEPROM Storage
  • Display Note 4-digit, 14 mm H (0.56"), red, 7-segment, LED display, Display Modes: Normal: process value(s) or blank Keypad: 3 keys for programming and unit operation
  • Display Type LED
  • Enclosure Ratings IP54, NEMA Type 3
  • Height 355.6 mm
  • Impedance Input >100 MΩ for T/C and mV inputs, 100 kΩ for 5 V inputs, 4.7 Ω for µA inputs
  • Input Note Input Correction: Offset adjustment: 999 to 999 units;Input Isolation: 350 Vac, 500 Vdc
  • LED Indicators 5 Red LED Alarm Status Indicators, 1 green LED pen 2 indicator
  • Length 96.5 mm
  • Materials Noryl, Acrylic
  • Measurement Range Note Thermocouple: J: 0 to 760°C, K: 0 to 1360°C, T: -200 to 400°C, R: 200 to 1650°C, S: 200 to 1650°C RTD: -140 to 400°C Current: 0 to 20 mA, 4 to 20 mA Voltage: 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
  • Measurement Type Thermocouple, RTD, Current, Voltage
  • Mounting Panel Mount or Wall Mounting
  • NMRR 85 db @ 60 Hz or greater
  • Operating Environment Reference Operating Condition: 25 °C
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Panel Depth 64 mm
  • Panel Protrusion 33 mm
  • Pen Type Disposable Fiber tip
  • Power Consumption 18 VA
  • Relative Humidity 10 to 90% RH, non-condensing
  • RTD Type 100 Ω Pt sensor; α= 0.00385
  • Sampling Rate 1 Scan per second for Non-RTD inputs; 1 Scan per 1.2 seconds for RTD inputs
  • Sensor Input Configuration 150 µA
  • Standard Limits of Error Error Limit: Cold-Junction Compensation Error: ±0.2°C @ 25°C, Linearization Error: T/Cs: ±0.25°C typical, ±0.5°C worst case , RTDs: ±0.1°C typical, ±0.3°C worst case, Ambient Temperature Error: ±0.01% of span per °C deviation from 25°C; Measurement Error: Type J, K, T, R, S and RTD: ±0.25% of span ±1 degree; mA, mV and Vdc: ±0.25% of scaled span plus 1 leastsignificant digit
  • Storage Temperature, Max 65 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note Line Voltage: 90/264 Vac, 50/60 Hz; optional: 20 to 50 Vac, 50/60 Hz, or 22 to 65 Vdc
  • Supply Power Type AC
  • Supply Voltage 90 to 264 Vac
  • Switch Rating 5 A @ 115 Vac
  • Switch Rating Note Relays: SPDT; contacts rated 5 A resistive @ 115 Vac,2.5 A resistive @ 230 Vac, 1⁄8 hp @ 230 Vac (single phase),250 VA @ 115/230 Vac
  • Switch Type SPDT NO/NC, Selectable
  • Temperature Measurement Range J: 0 to 760°C, K: 0 to 1360°C, T: -200 to 400°C, R: 200 to 1650°C, S: 200 to 1650°C, RTD: -140 to 400°C
  • Thermocouple Type J, K, T, R, S
  • Voltage Measurement Range 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
  • Weight 8.8 kg
  • Width 355.6 mm
  • Wire Code Option 2- or 3- Wire
CT5100 Series Circular Chart Recorders measure and display up to two process variables. Choose from a variety of programmable inputs. All recorder and alarm functions are easily configured via front 3-key pad with self prompting displays. Total panel depth of only 2.5" is required with only a 1.3" protrusion from the front of the panel.
Rated 4 out of 5 by from USER FRIENDLY WE HAVE HAD THESE FOR A FEW YEARS . TWELVE OF THEM THROUGH OUT THE PLANT THEY HAVE WARE AND TEAR, SO WE NEED A PART BREAK DOWN AND SERVICE MANUEL .I AM TOLD THEY IS NONE. WHY?
Date published: 2017-07-31
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_CT5100, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Hi, i bought the CT5100 due to power surge the power board burn. Do you supply sparepart for this model?

Asked by: Chng
Thank you for your inquire Please email the temperature group to see pricing, Leadtime Temp@omega.com
Answered by: application engineer je
Date published: 2021-09-10

Does Omega offer a chart temp recorder with 100 ohm RTD and NEMA -3 enclosure designed for outdoor use?

Asked by: MIke76
Hi Mike76 Thank you for the inquiry. We do not offer chart recorder designed for outdoor use. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-03-24
  • y_2025, m_2, d_22, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_CT5100, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 9ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration