PR-25AP

-100 °C to 250 °C RTD Air Temperature Probes M12 Connector

Models In Stock
PR-25AP
From $ 195.50
Models In Stock
-100 °C to 250 °C RTD Air Temperature Probes M12 Connector PR-25AP PR-25AP
loading all models
Product Overview

Accessories

OMEGALOK™ Compression Fittings
C$16.78
440 In Stock
DC Cable Assemblies for Probes, Sensors and Transmitters
C$30.43
65 In Stock
DC Cable Assemblies for Probes, Sensors and Transmitters
C$37.25
126 In Stock
DC Cable Assemblies for Probes, Sensors and Transmitters
C$33.92
9 In Stock
DC Cable Assemblies for Probes, Sensors and Transmitters
C$24.75
27 In Stock
DC Cable Assemblies for Probes, Sensors and Transmitters
C$61.50
13 In Stock
DC Cable Assemblies for Probes, Sensors and Transmitters
C$37.99
12 In Stock
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
C$117.98
1 In Stock
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
C$81.57
40 In Stock
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
C$89.65
14 In Stock
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
C$113.25
12 In Stock
High Temperature M12 Extension Cables
C$163.12
0 In Stock
High Temperature M12 Extension Cables
C$212.08
0 In Stock
High Temperature M12 Extension Cables
C$100.54
26 In Stock
High Temperature M12 Extension Cables
C$122.55
0 In Stock
High Temperature M12 Extension Cables
C$205.67
0 In Stock
High Temperature M12 Extension Cables
C$100.54
115 In Stock
High Temperature M12 Extension Cables
C$132.54
40 In Stock
Miniature Temperature Transmitter for Sanitary RTD Probes and Sensors
C$309.33
0 In Stock
OMEGALOK™ Compression Fittings
C$35.02
258 In Stock
Rated 5 out of 5 by from Everything You Want from an RTD Simple, accurate, and reliable. I used these for all clean air applications.
Date published: 2025-01-22
Rated 5 out of 5 by from My Go-To Easy Order, Great Packaging. My Go-To source for Temp supplies
Date published: 2024-07-08
  • y_2025, m_4, d_13, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_PR-25AP-1-10-0200-1-4-M12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

What is the 50% response time for these sensors?

Asked by: NCPerry
Thank you for your inquiry! 50% Response is the time the resistance thermometer element needs in order to reach 50% of its steady state value. 90% Response is defined in a similar manner. These response times of elements are given for water flowing with 0. 2 m/s velocity and air flowing at 1 m/s. For more information on RTD response time, please see this Technical Reference from our UK site: https://www.omega.co.uk/temperature/z/resistanceelements.html
Answered by: Application Engineer CB
Date published: 2022-01-11

Is your "1/10 DIN" RTD actually "1/10*Class B" across their full operating range or only at 0°C? For example, is their accuracy ±0.13°C at 200°C (1/10 of Class B, which is ±1.30°C) or something else? If something else, please provide a formula or table.

Asked by: RyanJ
Thank you for your inquiry. This is the tolerance equation for it: 1⁄10 DIN = ±1⁄10* (0.3 + 0.005*t)°C or 100.00 ±0.03 Ω at 0ºC
Answered by: Application Engineer CB
Date published: 2021-06-29

can you tell me the response time? the documentation just says fast. How fast?

Asked by: JasonK
Thank you for your inquiry! 50% Response is the time the resistance thermometer element needs in order to reach 50% of its steady state value. 90% Response is defined in a similar manner. These response times of elements are given for water flowing with 0. 2 m/s velocity and air flowing at 1 m/s. For more information on RTD response time, please see this Technical Reference from our UK site: https://www.omega.co.uk/temperature/z/resistanceelements.html Application Engineer CK
Answered by: Application Engineer CK
Date published: 2022-01-10

Is this temperature probe submersible into liquids?

Asked by: Claire
Thank you for your inquiry. This air probe is designed for measuring air only and cannot be submersed in liquids. We offer sealed probes that are designed for liquid submersion.
Answered by: Application Engineer JB
Date published: 2020-11-19

I know what a response time is and that they are determined either in water at 0. 2 m/s velocity and air flowing at 1 m/s. What is the response time for this sensor?

Asked by: NCPerry
Thank you for your inquiry. Response Time would be less than 5 seconds.
Answered by: CB Application Engineer
Date published: 2022-01-25
  • y_2025, m_4, d_14, h_20CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_PR-25AP-1-10-0200-1-4-M12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 12ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration