Welcome to our new website, found an issue or bug? Please report it here
DP3001-3

Choose a Variant
Supply Voltage
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-9 | $352.06 |
10-24 | $334.46 |
25-49 | $316.85 |
50-99 | $299.25 |
100-499 | $281.65 |
500+ | $264.05 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
A/D Conversion | Dual-slope, average value |
Accuracy | ± 0.01 % of reading ± 2 counts |
Cutout Dimensions | 45 x 92 mm |
Depth Behind Panel | 104 mm |
Digital I/O Note | HOLD and TEST Inputs: TTL or 5 V CMOS compatible Blanking Input: Open-collector compatible |
Display Size | 14 mm (.56 in) |
Display Type | 4.5 Digit LED |
Display Type Note | Symbols: -1.8.8.8.8 Decimal Points: Four positions selectable by jumpers from front panel or at connector, 10 mA sink Overrange Indication: Four least-significant digits flash |
Enclosure Material | Polycarbonate |
Enclosure Ratings | IP65, NEMA Type 4 |
Form factor | 1/8 DIN |
Front Bezel | 96 W x 48 H x 5.1 D mm |
Impedance Input | 1 GΩ |
Input Configuration | Bipolar, Differential |
Input Range Note | Analog Input Range: ±2, ±20, ±200 V External Reference Input: +0.5 to +2.0 V Load on Reference, Std: 6 kΩ Load on Reference, Opt: 100 MΩ |
Noise Rejection | NMR, SIG HI to SIG LO: 56 dB, 50/60 Hz ;CMR, SIG LO to ANA GND: 86 dB, DC to 60 Hz ;CMR, AC GND to ANA GND: 120 dB, DC to 60 Hz ;CMV, SIG LO to ANA GND: ±1 Vp ;CMV, AC GND to ANA GND: 1500 Vp per HV test, 354 Vp per IEC spacing |
Operating Temperature, Max | 60 °C |
Operating Temperature, Min | 0 °C |
Polarity | Automatic |
Power Consumption | 2.5 W |
Reading Rate | 2.5 samples/sec |
Relative Humidity | 95% at 40°C (non-condensing) |
Resolution | 100 µV |
Sensor/Transmitter Power | 4.7 Vdc and -4.6 Vdc ±5%,10 mA max |
Signal Integration Period | 100 ms |
Span Adjustment | ± 5 % |
Step Response | 1 sec |
Storage Temperature, Max | 85 °C |
Storage Temperature, Min | -40 °C |
Supply Power Note | AC Voltages: 115 or 230 Vac ±15% AC Frequency: 49 to 440 Hz DC Voltages: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp Power Consumption: 2.5 W |
Supply Voltage | 9 to 56 Vdc, 115 to 230 Vac |
Thermal Span Effect | ±0.01% of reading/°C |
Voltage Measurement Range | ±1.9999 Vdc |
Warm-Up to Rated Accuracy | 10 min |
Weight | 400 g |
See All Specs |