HH501DK

4-Channel Type-K Thermometer with Backlit Display

Choose a Variant

Display Type

$191.77

Item# HH501DK

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $191.77
5-9 $182.18
10-24 $178.35
25-49 $170.68
50-99 $166.84
100+ $163.00

In Stock

Lead Time (If not in stock): 12 weeks

Product Specs

<< See all Product Models
Brand
Additional Features 1 Read HOLD,MAX Function
Battery Indication “+ -” is displayed when battery voltage drops below operating level
Diameter 53 mm
Display Type 3.5 Digit LCD
Display Type Note 3 1⁄2 digit liquid crystal display (LCD) with maximum reading of 1999 Default Display Output : Zero : Automatic
Electrical Connection Sub-D Male Miniature Connector
Height 195 mm
Measuring Temperature Range, Max 1300 °C
Measuring Temperature Range, Min -50 °C
Number of Channels 4
Operating Temperature Note 0 to 50°C (32 to 122°F)@ <70% RH
Operating Temperature, Max 50 °C
Operating Temperature, Min 0 °C
Overrange (OL) or (-OL) is displayed
Polarity Automatic, positive implied, negative polarity indication
Relative Humidity, Max 0.8
Relative Humidity, Min 0%
Sampling Rate 2.5 Hz (2.5 updates/second)
Storage Temperature Note -20 to 60°C (-4 to140°F), 0 to 80% RH with battery removed from meter
Storage Temperature, Max 60 °C
Storage Temperature, Min -20 °C
Supply Voltage 9 Vdc
Temperature Accuracy ± 0.3%
Temperature Accuracy Note ± (0.3% rdg + 1°C) -50 to 1000°C; ± (0.5% rdg + 1°C) 1000 to 1300°C; ± (0.3% rdg + 2°F) -58 to 1999°F Stated accuracy : 23°C ± 5°C <75% relative humidity (accuracy specification does not include
Temperature Resolution 0.1 °C
Temperature Sensor Type Thermocouple
Thermocouple Type K
Weight 250 g
Weight Note Approximately 250 g (9 oz) including battery
Width 92 mm
See All Specs Show Less
4-Channel Type-K Thermometer with Backlit Display HH501DK HH501DK
Rated 5 out of 5 by from Design problem I used a shorting bar to check the four inputs to see if they were the same. They indicated the ambient temperature but, when the supplied thermocouples were plugged in, a different ambient temperature was indicated. I assume that this is due to the tolerance of the thermocouple wire. A bigger difficulty was the spacing of the TC receptacles. When all four TCs are plugged in, it is very difficult to remove one of the plugs. It was necessary for me to pry two of them out with a small screwdriver before the other two could be removed. This is a design problem that should never been approved for manufacture.
Date published: 2020-11-23
  • y_2025, m_2, d_21, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_HH501DK, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
en-US
en
Save Configuration