Welcome to our new website, found an issue or bug? Please report it here

OM-EL-USB-LITE-5-Loggers
5 Pack Temperature Data Logger with USB Interface
Models In Stock
- USB Interface for Setup and Data Download
- -10 to 50°C (14 to 122°F) Measurement Range
- 2 User-Programmable Alarm Thresholds
- Red/Green Alarm Status Indication via Pushbutton
OM-EL-USB-LITE-5-Loggers
From
$
278.41
Models In Stock

Product Overview
- Alarm Note 2 (user programmable)
- Battery life 1 mo
- Battery Size and Type CR2032, 3V Li-ion
- Data Interface USB
- Height 9.4 mm
- Input Type Internal
- Internal Resolution 1 °C
- LED Indicators Red/green alarm status indication via pushbutton
- Length 68 mm
- Measurement Type Temperature
- Memory 4080
- Number of Measurements 1
- Operating Temperature, Max 50 °C
- Operating Temperature, Min -10 °C
- Pack Size 5
- Samples,Max 4080
- Sampling Rate 30 minutes between updates
- Sampling Rate Note 30 minute (fixed)
- Software Compatibility WIN XP/Vista/7 and 8 (32-bit and 64-bit)
- Supply Power Type Battery
- Temperature Accuracy ± 2.5 °C
- Temperature Measurement, Max 50 °C
- Temperature Measurement, Min -10 °C
- Weight 30 g
- Width 18 mm
The OM-EL-USB-LITE is a low-cost temperature data logger that measures and stores up to 4080 temperature readings over a -10 to 50°C (14 to 122°F) measurement range. It has a fixed 30-minute sample rate and a battery life of 1 month with continuous use. Press the button and a red/green LED indicates whether a preset alarm level has been breached. The data logger is configured and the stored data is downloaded by plugging the module into a PC's USB port and running the control software under Windows XP SP3/Vista/7 and 8. The downloaded data can be graphed, printed, and exported to other applications. A battery comes installed. To start logging, pull out the tab.
Battery Replacement
The user should replace the battery every month, or before logging critical data. The OM-EL-USB-LITE does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will stop and cannot restart until the battery has been replaced and the logged data has been downloaded to a PC.
For maximum logging life, use only OM-EL-BATT-LITE replacement batteries. Before replacing the battery, remove the OM-EL-USB-LITE from the PC.
Note: Leaving the OM-EL-USBLITE plugged into the USB port for longer than required will shorten battery life.
LED Flashing Modes
The OM-EL-USB-LITE has a bicolor LED status light. To save power, it operates for only a short time after the pushbutton is released.
Specifications
Measurement Range: -10 to 50°C (14 to 122°F)
Internal Resolution: 1°C (2°F)
Accuracy: ± 2.5°C (± 4.5°F)
Memory: 4080 readings
Logging Interval: 30 minute (fixed)
Operating Temperature Range: -10 to 50°C (14 to 122°F)
Alarm Thresholds: 2 (user programmable)
Start Date/Time: Selectable in software
Status Indicators (LEDs): Red/green alarm status indication via pushbutton
Software: Windows XP SP3/Vista/7 and 8 (32- and 64-bit)
Power: 3 V coin cell battery (included)
Battery Life: 1 month
Weight: 30 g (1 oz)
Dimensions:
68 x 18 x 9.4 mm (2.7 x 0.7 x 0.4' )
Battery Replacement
The user should replace the battery every month, or before logging critical data. The OM-EL-USB-LITE does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will stop and cannot restart until the battery has been replaced and the logged data has been downloaded to a PC.
For maximum logging life, use only OM-EL-BATT-LITE replacement batteries. Before replacing the battery, remove the OM-EL-USB-LITE from the PC.
Note: Leaving the OM-EL-USBLITE plugged into the USB port for longer than required will shorten battery life.
LED Flashing Modes
The OM-EL-USB-LITE has a bicolor LED status light. To save power, it operates for only a short time after the pushbutton is released.
Specifications
Measurement Range: -10 to 50°C (14 to 122°F)
Internal Resolution: 1°C (2°F)
Accuracy: ± 2.5°C (± 4.5°F)
Memory: 4080 readings
Logging Interval: 30 minute (fixed)
Operating Temperature Range: -10 to 50°C (14 to 122°F)
Alarm Thresholds: 2 (user programmable)
Start Date/Time: Selectable in software
Status Indicators (LEDs): Red/green alarm status indication via pushbutton
Software: Windows XP SP3/Vista/7 and 8 (32- and 64-bit)
Power: 3 V coin cell battery (included)
Battery Life: 1 month
Weight: 30 g (1 oz)
Dimensions:
68 x 18 x 9.4 mm (2.7 x 0.7 x 0.4' )
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 5 out of
5
by
Katherine from
I really like these!
I have to have temp traces for shipments. These work great
Date published: 2016-05-23
Rated 5 out of
5
by
Microbiology from
Great Value and Ease of Use
Great Value. Will meet the needs of monitoring incubators over the off hours to verify no excursions.
Date published: 2022-08-26
are these water resistant? does this record temp readings over a period of time and if so what length of time and at what interval?
Hello, thank you for your question.
These are not water resistant. The OM-EL-USB-LITE is a low-cost temperature data logger that measures and stores up to 4080 temperature readings over a -10 to 50°C (14 to 122°F) measurement range. It has a fixed 30-minute sample rate and a battery life of 1 month with continuous use.
Date published: 2019-12-28