Call us at 1-800-663-4209
Quantity | Price each |
---|---|
1-4 | $2,265.78 |
5-9 | $2,152.49 |
10-24 | $2,107.18 |
25-49 | $2,016.54 |
50-99 | $1,971.23 |
100+ | $1,925.91 |
Brand |
![]() |
Accuracy | ± 3.5 % |
Accuracy Detail | Vibration Measurement:±3.5%, Process Measurement:±0.75%, Analogue output:±1.5%, Speed Sensors:±0.5% |
Alarm Type Note | alert_and_danger_per_each_detector_with_adjustable_alarm_limits alert_delay_time_0_100_sec danger_delay_time_0_100_sec reset_time_for_alert_and_danger_0___100_sec |
Applications | Axial Position, Relative Shaft Vibration |
Approvals | CE |
Approvals Note | CE, ISO 13849-1, ISO 10816-3, VDI 3832, API 670 |
Capacitance | 10 nF |
Data Interface | USB, RS-485, Ethernet |
Electrical Output | 4-20 mA, 0-20 mA |
Enclosure Ratings | IP20 |
Frequency Response | 10 Hz – 1,000 Hz, -1 dB, 24 dB/oct. Selectable ranges e.g. 1-300/1,000 Hz, multiple filters settings 0.7-10,000 Hz Filter response: High pass and low pass filters;refer to the setup part for the specific parameters for the Cut-off freq., pass band attenuation, Stop band freq. and Stopband attenuation |
Height | 110 mm |
Input Configuration | Full scale vibration measuring ranges up to 1-100 mm/s,1-300 m/s2 ,0.1-15 mm Pk Pk |
Input Electrical Connection | Screw Terminals |
Input Range | 4 to 20 mA, 0 to 20 mA |
Input Resistance | ≥ 450 kΩ |
Input Type | Current |
LED Indicators | 5 light diodes indicate channel status (green, yellow, red) for each of the 4 vibration input channels, as well as for general system status |
Length | 114 mm |
Modularity | Link Concept modularity: VIBROCONTRL 1800 Series –all components -Vibration Monitor, EtherBridge, Relay Module, Input and Output Modules can be interconnected by means of DIN rail bus connectors |
Number of Channels | 4 |
Operating Temperature, Max | 50 °C |
Operating Temperature, Min | -10 °C |
Output Signal | Current |
Peak Detection | Attack time of Peak Detector: 1 to 1,000 ms;Decay time of Peak Dettector:0.1 to 100 sec |
Recording Note | Up to 4 input channels can record digital raw data (time waveform) simultaneously to a PC running The recording can be done through: RS-485/LAN (buffered): Up to 10 kHz Mini USB (real-time): Up to 10 kHz Time waveform recording is user activated and contains scalar values for vibration and process input data at start of recording. |
Sensitivity | 0.8-8 V/mm |
Sensor Type | Displacement |
Storage Temperature, Min | -40 °C |
Test Function | Can be activated digitally or by PC. As default the alarm relays activate and DC outputs increase to the specified test level of 102 % |
Weight | 160 g |
Width | 23 mm |