Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

FMG470-03-D6N

3" Flanged Magnetic Flow Meter w/Integrated Display, Pulse Output, 60 Hz Power

$2,578.05

Item# FMG470-03-D6N

In Stock

Lead Time (If not in stock): 4 weeks

Product Specs

<< See all Product Models
Brand
Accuracy ± 1 %
Approvals CE
Battery Backup 7.2 V D size Lithium Battery
Battery Size and Type Li-ion, 7.2V
Cable Length 20 ft
Conductivity > 20 µS/cm
Display Note 128 x 64 dot-matrix LCD
Display Type LCD
Empty Pipe Detection Hardware/software, conductivity-based
Enclosure Ratings IP68, NEMA 6P
Flange Diameter 2.68 in
Low Flow Cutoff 0.50 %
Material Construction Option N/A
Materials Steel, Epoxy, Aluminum
Materials, Wetted EPDM, Polypropylene, Stainless Steel
Media Compatibility Acid Solutions, Conductive Liquids, Saltwater
Number of Digits 8
Number of Outputs 1
Operating Pressure, Max 150 psi
Operating Temperature, Max 60 °C
Operating Temperature, Min -12 °C
Output Detail Current Sinking pulse
Output Pulse Rate, Max 200 pulses/sec
Output Signal DC Pulse
Pipe Size, Max 12 in
Process Connection Size 12 in
Process Connection Type ANSI Flange
Pulse Rate Note User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5 ms, 200 pulses/sec max. For battery option meters, pulse width varies with frequency, 150 pulses/sec max
Storage Temperature, Max 70 °C
Storage Temperature, Min -40 °C
Supply Power Note 9-36 Vdc @ 250 mA max, 30 mA average
Supply Power Type DC
Supply Voltage 9 to 36 Vdc / 60 Hz
Velocity, Max 10 m/s
Volumetric Flow Rate, Max 11565 GPM
Volumetric Flow Rate, Min 57.82 GPM
Weight 170 lb
See All Specs Show Less
3" Flanged Magnetic Flow Meter w/Integrated Display, Pulse Output, 60 Hz Power FMG470-03-D6N FMG470-03-D6N
Rated 5 out of 5 by from Highly recommend This mag flow meter is an affordable option for applications that require accurate readings.
Date published: 2024-01-03
  • y_2025, m_2, d_20, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_FMG470-03-D6N, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
en-US
en
Save Configuration