Welcome to our new website, found an issue or bug? Please report it here
FMG801
PLASTIC BODIED ELECTROMAGNETIC FLOW METER

Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy | ± 1 % |
Accuracy Note | ± 1% of reading (between 10% and 100% of maximum flow) ± 3% of reading (between cutoff and 10% of maximum flow) |
Battery Size and Type | Alkaline AA |
Cable Length | 20 ft |
Conductivity | > 20 µS/cm |
Display Type | LCD |
Empty Pipe Detection | Hardware/software, conductivity-based |
Enclosure Ratings | NEMA Type 4X |
Materials | Aluminum, Polyethylene |
Materials, Wetted | 316 Stainless Steel, Glass, Polypropylene |
Media Compatibility | Acid Solutions, Conductive Liquids, Saltwater |
Number of Digits | 8 |
Number of Outputs | 1 |
Operating Pressure, Max | 150 psi |
Operating Temperature, Max | 54 °C |
Operating Temperature, Min | -12 °C |
Output Signal | DC Pulse |
Pipe Size, Max | 1 in |
Pipe Size, Min | 1 in |
Process Connection Note | 1 NPTF, 2 or 3" flange clamps with 2 or 3 NPTF fitting kit |
Process Connection Size | 1 in |
Process Connection Type | NPT Female |
Standard Pulse Rate | None |
Storage Temperature, Max | 80 °C |
Storage Temperature, Min | -40 °C |
Supply Power Note | FMG800: 6 each “AA” alkaline cells (included), replaceable. Estimated life is 1 to 2 years depending on usage, FMG810: 10 to 30 Vdc @ 60 mA maximum (15 mA average), NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation. |
Supply Power Type | Battery |
Volumetric Flow Rate, Max | 110 GPM |
Volumetric Flow Rate, Min | 2.3 GPM |
Weight | 0 lb |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 4 out of
5
by
85westymmm from
FMG810 does NOT have pulse output
I believe the model numbers (FMG800 and FMG810) are reversed in the description as to which one provides a pulse output. I believe the FMG800 requires a permanent power supply (non-battery operated) but provides a pulse output signal. The battery-operated FMG810 does NOT provide a pulse output.
Date published: 2017-12-28