Welcome to our new website, found an issue or bug? Please report it here
CL945A
Industrial Thermocouple Handheld Calibrator

Choose a Variant
Thermocouple Type
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $2,033.65 |
5-9 | $1,931.97 |
10-24 | $1,891.29 |
25-49 | $1,809.95 |
50-99 | $1,769.28 |
100+ | $1,728.60 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Additional Features 1 | Read and Source Signals |
Auto Off | 20 min |
Auto Off Note | 20 minute no key pressed Auto Off. Feature can be disabled |
Battery Indication | 4 stage battery charge indication |
Battery life | 500 hr |
Cold Junction Error | ± 0.15 °C |
Common Mode Voltage | 42 V |
Common Mode Voltage (CJC error), Max | 1 V |
Common Mode Voltage Note | 42 V peak to earth; 1 V p-p between T1 and T2 |
Compliance | CE, Mil-PRF-28800F Class 2, REACH, RoHS 2 |
Dimensions (CJC error) | 7.6 L x 3.3 W x 1.1 H in |
Display Backlight | Four (4) LED Backlight with 30-second timeout |
Display Measuring Units | °C, °F, mV |
Display Resolution | 0.01° |
Display Resolution (CJC error) | 0.1° |
Display Type | Backlit LCD |
Display Type Note | 5-DIGIT AUTO-RESOLUTION (0.1/0.01) WITH BACKLIGHT AND FUNCTION ANNUNCIATORS Two (2) rows of Five (5) digit LCD with separate minus sign, decimal indicators, with offset, thermocouple types KJTEBNRSGCDPLU, battery, source, read, temperature units, voltage units, percent, trend, PRST (0-19), MIN, MAX, AVG, RNG, STDEV, Transfer, symbols: Fast Ramp, Slow Ramp, Step, Bluetooth |
EMC Standard | Class 2, EN 61326, MIL-PRF-28800F |
ESD Standard | IEC 61326 Criterion B |
Electrical Connection | Miniature Female Thermocouple Connector |
Electrical Safety | IEC-61010 |
Height | 28 mm |
Input Current | ± 50 nA |
Internal Preset Storage | 20 user defined presets available |
Keypad | 12 Switches |
Length | 193 mm |
Low Resistance Load | Less than 5µV change in output with a 100KΩ resistance |
Millivolt Range | -15 to 85 mV |
Operating Environment | Altitude: 0 to 4600 m ; 0 to 15,092 ft(CJC Error) Vibration: Random 10 – 500 Hz; 0.03 g2/Hz(CJC Error) Shock: 30g Half Sine Drop: 4 Drops from 1 m to Concrete |
Operating Temperature Note | Operating Temperature(CJC error): -4 to 131°F |
Operating Temperature, Max | 55 °C |
Operating Temperature, Min | -20 °C |
Power Cycle Configuration Retention | Instrument retains: Sensor Type, Temperature Unit Offset Values, Presets, Statistics, Open Lead detection status, 0%/100% span settings, and operating mode |
Probe Offset Uncertainty | Resolution 0.1 °C/°F |
Reading Rate | 3/sec |
Reading Rate Note | 3/sec. for Readings and TREND indicators |
Relative Humidity Note | <10 °C (50 °F): Non-condensing 10 to 30 °C (50 to 86 °F): 5 to 95% RH 30 to 40 °C (86 to 104 °F): 5 to 85% RH 40°C to 55°C (104 to 131 °F): 5 to 60% RH |
Relative Humidity, Max | 0.95 |
Relative Humidity, Min | 5% |
Resolution Note | 0.01°C UP TO 999.99°C AND 0.1°C ≥ 1000°C |
Resolution, Max | 999.99 °C |
Resolution, Min | 0.01 °C |
Sanitation | NSF, ANSI/3-1 14159-2 |
Statistics | Average, Maximum, Minimum, Range, Standard Deviation |
Storage Temperature Note | Storage Temperature(CJC error): -59.8 to 159.8°F |
Storage Temperature, Max | 71 °C |
Storage Temperature, Min | -51 °C |
Supply Voltage | 4.5 Vdc |
Temperature Coefficient | For specification variances due to ambient operating temperature, see the Expanded Instrument Uncertainty charts in Appendix B of this manual. For ambient operating temperatures not shown in Appendix B, accuracies shall be interpolated linearly. |
Thermocouple Type | J, K, T, E, R, S, B, C, N, L, G, U, D, P |
Weight | 362.9 g |
Weight (CJC error) | 12.8 oz (including batteries) |
Weight Note | 362.9g (including batteries) |
Width | 84 mm |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
Pavanth from
great product, needs accessories
great use for our purpose, If they have included male to male extension for the TC calibration it would have been great.
Date published: 2024-04-29
Rated 4 out of
5
by
Servicemgr from
Works as we need it to. A bit too expensive
Tool works great. Meets our needs although requires a capacitor the older model didn’t to calibrate multiple zones at once.
Date published: 2023-05-08
Rated 5 out of
5
by
Jerry Gu from
Director
Very reliable and trustable , have been working with Omega for two decades
Date published: 2023-04-11
Rated 4 out of
5
by
Anonymous from
CL 940 review
Excellent unit, but wish it had a rubberized protective grip case like our CL25 does
Date published: 2020-09-28