Welcome to our new website, found an issue or bug? Please report it here

PTRA-PTRM
Ceramic Protection Tubes with Optional Fittings
Models In Stock
- Maximum Service Temperature to 1700°C (3092°F) for OMEGATITE™ 450
- Standard Lengths of 12, 18 and 24 Inches
- Tubes Supplied Standardly Without Fittings. Consult Sales for Optional Fittings.
PTRA-PTRM
From
$
21.15
Models In Stock

Product Overview
- Fabrication Methods Cast
- Gas Permeability Gas Tight
- Hardness 9 Mohs
- Operating Temperature, Min 0 °C
- Sensing End Closed
- Te Value 800 °C
- Te Value Note Te Value (Volume Resistivity of 1 mega Ω cm): 800°C (1470°F)
- Volume Resistivity 10^13 Ω-cm
Ceramic Thermocouple Protection Tubes
*Length: The tube lengths shown are standard lengths for a tube without any fittings. Special lengths are also available. Consult Sales.
PDFs & Manuals
Show Ratings & Reviews
Rated 4 out of
5
by
Aaron from
Ceramic Thermocouple
The product quality is great and works for the most part. Unfortunately, the 24 inch section I purchased arrived broken in 3 pieces. Now I know the shipping company probably stacked a refrigerator on top of this box but the packaging could have been better to protect the fragile material inside. In comparison, I have purchased steel from suppliers who package tough steel bar better than this thermocouple was packaged. This is why I only gave 4 out 5 stars.
Date published: 2017-03-13
Rated 5 out of
5
by
Kirk C from
Ceramic protection tubes
Ceramic tubes came as ordered packaged well and undamaged.
Date published: 2023-11-27
Rated 5 out of
5
by
Mikep from
They are the exacted size they are supposed to be
They work grate and They are the exacted size they are supposed to be
Date published: 2023-04-19
Rated 1 out of
5
by
Anonymous from
It's not 0.25" OD. It's 0.26" ... doesn't fit.
I purchased the PTRA-31614-24 which is sold as a 0.25" OD, but it won't fit into any of my 0.25" hardware. I measured with calipers and it's 0.26"?
Can't use them.
Date published: 2022-02-25
Rated 1 out of
5
by
Anonymous from
Need better packaging when shipped.
The products came all broken, we couldn't use them.
Date published: 2020-10-01
Hello. What is your recommended bonding method for attaching metal fittings to these ceramic tubes? Thanks
Omega use's its CC HIGH TEMP Cement to bond the metal fittings to the tubes.
Date published: 2024-04-05
For the Alumina tube with 0.187 inch inner diameter (PTRA-31614-18), does it work with the KQIN-316U-18 thermocouple, which has a 0.187 inch outer diameter? Is there enough tolerance so that the thermocouple can be inserted with no issues?
It is recommended to go one size larger on the id as the tolerance of probe and tube would not be enough to guarantee insertion.
Date published: 2021-04-13