Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

TRCIII-A-Series

Portable Ice Point Calibration-Temperature Reference Chamber

  • New Stylish Design
  • Portable Rugged Case for Use in the Factory, Calibration Laboratory, or Instrument Shop
  • Built in Temperature Readout with 0.1° Resolution [°F/°C]
  • Accepts up to 6 Probes at One Time
TRCIII-A-Series
From $ 7,002.36
Portable Ice Point Calibration-Temperature Reference Chamber TRCIII-A-Series TRCIII-A-Series
loading all models
Product Overview
  • Accuracy ± 0.1 °C (± 0.18 °F)
  • Display Resolution 0.1 (°F/°C) Resolution)
  • Form factor Portable Benchtop
  • Frequency 50 Hz
  • Height 203 mm
  • Length 305 mm
  • Number of Reference Wells 6
  • Number of Reference Wells Note 6 wells, 4.0 mm (5⁄32") ID, 95.25 mm (3 3⁄4") deep; wells are thermally and electrically grounded to each other; accepts
  • Operating Temperature, Max 32 °C
  • Operating Temperature, Min 2 °C
  • Reference Temperature 0 °C
  • Reference Wells Depth 3.75 in
  • Reference Wells Inner Diameter 0.1563 in
  • Stability ± 0.03°C
  • Stabilization Time 2 hours after initial power up
  • Supply Power Note 115/230 Vac, 50 Hz, 104 W
  • Weight 11.8 kg
  • Width 419 mm
The new ice point™ reference chamber TRCIII-A is the latest addition to OMEGA’s fine line of calibration reference instrumentation. The TRCIII-A ice point™ reference chamber relies on the equilibrium of ice and distilled, deionized water at atmospheric pressure to maintain six reference wells at precisely 0°C. Each well extends into a sealed cylindrical chamber containing the distilled deionized water. The outer walls of the chamber are cooled by thermoelectric cooling elements. The increase in volume produced by the creation of ice crystals within the cell is sensed by the expansion of a bellows, which operates a micro switch and controls the cooling elements. The alternate freezing and thawing of the ice accurately maintains a 0°C environment around the reference wells. The TRCIII-A has a built in temperature readout [°C/°F] with 0.1° resolution. The unit comes with a NIST-traceable calibration certificate.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 17ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration