Product Specs
<< See all Product ModelsAccuracy | ± 1 % |
Cable Length | 15 ft |
Calibration Option | Factory Calibrated |
Certifications | CE |
Data Interface | BACnet MS/TP, Modbus RTU, USB |
Display Language | English |
Display Note | Keypad : 4-button navigation, keypad with tactile feedback; polyester film Display128 × 64 pixel LED backlit graphical display; adjustable brightness and timeout; polycarbonate window |
Display Type | LED |
Electrical Connection | 1/2 in NPT female Conduit with Poly Cable Glands |
Electrical Output | 4 to 20 mA, Two Pulse, Frequency |
Enclosure Ratings | IP67, NEMA 4 |
Form factor | Pipe Remote mount |
Keypad | Yes |
Materials | PVC, CPVC, HDPE, PTFE, PDVF, Stainless Steel, Ductile Iron, Aluminum, Brass, Carbon Steel, Copper |
Measurement Type | Transit Time |
Number of Digits | 8 |
Number of Outputs | 4 |
Operating Temperature, Max | 60 °C |
Operating Temperature, Min | -20 °C |
Output Detail | 4-20 mA output:One 16-bit, isolated, max 800 Ohms, internal or external power Digital output:Two selectable pulse, alarm, flow direction, sink isolated open collector, 5-30V DC, max. 50 mA externally or internally sourced Frequency output: 50% duty cycle, 63-10k Hz maximum frequency Pulse (totalizer) output: 5 kHz max. output, open collector, pulse width 5-500 ms programmable Optional: Two dry contact output for alarm or flow direction 30V DC max., 5A max. (Ethernet not available with this option); Open Collector Output: 5 to 30 Vdc, max. 50 mA externally or internally sourced |
Pipe Size, Max | 48 in |
Pipe Size, Min | 8 in |
Process Temperature, Max | 90 °C |
Process Temperature, Min | -40 °C |
Pulse Rates | 5 KHz |
Relative Humidity | 85% non condensing |
Repeatability | 0.002 |
Repeatability Note | 0.2% above 1.5 ft/s |
Software | SoloCUE |
Storage Temperature, Max | 80 °C |
Storage Temperature, Min | -40 °C |
Supply Power Type | DC |
Supply Voltage | 9 to 28 Vdc |
Transducer Type | Large pipe |
Velocity, Max | 40 ft/s |
Velocity, Min | 0.1 ft/s |
Volumetric Flow Rate, Max | 33000 GPM |
Volumetric Flow Rate, Min | 0 GPM |
See All Specs |