Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

UFM-DQG-Series

Clamp on Ultrasonic Flow Meter/Data Logger For 2.5 in to 48 in Pipes

  • Reduced installation time and cost
  • Non-invasive, non-contact measurement
  • Continued operation during installation—no need to shut down the process
  • No pressure head loss
UFM-DQG-Series
From $ 4,398.60
Clamp on Ultrasonic Flow Meter/Data Logger For 2.5 in to 48 in Pipes UFM-DQG-Series UFM-DQG-Series
loading all models
Product Overview
  • Accuracy ± 1 %
  • Calibration Option Factory Calibrated
  • Certifications CE
  • Data Interface BACnet MS/TP, Modbus RTU, USB
  • Display Language English
  • Display Note Keypad : 4-button navigation, keypad with tactile feedback; polyester film Display128 × 64 pixel LED backlit graphical display; adjustable brightness and timeout; polycarbonate window
  • Display Type LED
  • Electrical Connection 1/2 in NPT female Conduit with Poly Cable Glands
  • Electrical Output 4 to 20 mA, Two Pulse, Frequency
  • Enclosure Ratings IP67, NEMA 4
  • Form factor Pipe Remote mount
  • Keypad Yes
  • Materials PVC, CPVC, HDPE, PTFE, PDVF, Stainless Steel, Ductile Iron, Aluminum, Brass, Carbon Steel, Copper
  • Measurement Type Transit Time
  • Number of Digits 8
  • Number of Outputs 4
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -20 °C
  • Output Detail 4-20 mA output:One 16-bit, isolated, max 800 Ohms, internal or external power Digital output:Two selectable pulse, alarm, flow direction, sink isolated open collector, 5-30V DC, max. 50 mA externally or internally sourced Frequency output: 50% duty cycle, 63-10k Hz maximum frequency Pulse (totalizer) output: 5 kHz max. output, open collector, pulse width 5-500 ms programmable Optional: Two dry contact output for alarm or flow direction 30V DC max., 5A max. (Ethernet not available with this option); Open Collector Output: 5 to 30 Vdc, max. 50 mA externally or internally sourced
  • Process Temperature, Min -40 °C
  • Pulse Rates 5 KHz
  • Relative Humidity 85% non condensing
  • Repeatability 0.002
  • Repeatability Note 0.2% above 1.5 ft/s
  • Software SoloCUE
  • Storage Temperature, Max 80 °C
  • Storage Temperature, Min -40 °C
  • Velocity, Max 40 ft/s
  • Velocity, Min 0.1 ft/s
  • Volumetric Flow Rate, Min 0 GPM

The TFX-5000 transit time ultrasonic flow meter measures volumetric flow and heating/cooling energy rates in clean liquids as well as those with small amounts of suspended solids or aeration, such as surface water or raw sewage.

TFX-5000 flow meter clamps onto the outside of pipes and do not contact the internal liquid.


APPLICATION

The TFX-5000 meter is available in a variety of configurations that permit the user to select a meter with features suitable to meet particular application requirements.
The TFX-5000 meter is suitable for:

- Water Delivery
- Sewage
- Cooling Water
- Water-glycol mixtures
- Alcohols
- Chemicals



OPERATION

Transit time flow meters measure the time difference between the travel time of an ultrasound wave going with the fluid flow and against the fluid flow. The time difference is used to calculate the velocity of the fluid traveling in a closed-pipe system. The transducers used in transit time measurements operate alternately as transmitters and receivers. Transit time measurements are bi-directional and are most effective for fluids that have low concentrations of suspended solids and are sonically conductive.


Model Construction Cable Length Pipe/Tubing Sizes
RZ (IP54), Standard pipe PBT glass filled, Ultem®, Nylon cord grip PVC cable jacket; –40…250° F (–40…121° C) 300 ft (90 m) max. 2.5…10 in. (DN65…DN250)
LZ (IP67) large pipe CPVC, Ultem, Nylon cord grip Polyethylene cable jacket; –40…194° F (–40…90° C) 300 ft (90 m) max 8…48 in. (DN200…DN1200)
KZ (IP54), Standard pipe, Integrated rail PBT glass filled, Ultem®, Nylon cord grip PVC cable jacket; –40…250° F (–40…121° C) 100 ft (30 m) max 2.5…10 in. (DN65…DN250)
2.5…12 in. (DN65…DN300)
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 23ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Does this meter have a straight line pipe requirement?

Asked by: MDugan
Thank you for your inquiry. Yes, typically a straight run of 10x the pipe diameter upstream and 5x the pipe diameter downstream will be sufficient.
Answered by: Application Engineer JC
Date published: 2024-03-14
  • y_2025, m_2, d_21, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_DQ-G-KZ-B-S-AC-WW-S-XX-S-G-F, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 41ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration