Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

Model-CMS300

CO Transmitter & Switch w/ Relay, 25/60/150 PPM, Ideal for Garages

  • Field selectable current or voltage analog outputs
  • Integral SPDT relay contact for low or high alarm
  • Jumper selectable alarm set points of 25, 60, or 150 PPM
  • UL recognized carbon monoxide sensing element
  • Field calibration kits
Model-CMS300
From $ 170.00
CO Transmitter & Switch w/ Relay, 25/60/150 PPM, Ideal for Garages Model-CMS300 Model-CMS300
loading all models
Product Overview
  • Accuracy ± 5 ppm or 5 %
  • Compliance CE, UL
  • Compliance Note Sensor is UL recognized component for ANSI/UL-2034, UL-2075, E340403, CE
  • Coverage Area 7500 sq ft
  • Display Type N/A
  • Drift <5%/Year in Air
  • Enclosure Type IP64
  • Gas Concentration 0 to 300 ppm
  • Materials Glass-Filled Polycarbonate
  • Operating Temperature, Max 122 °F
  • Operating Temperature, Min -4 °F
  • Output Detail Jumper selectable 4-20 mA (loop powered) or 2-10 V (max. load 2 kΩ)
  • Output Signal Current, Voltage
  • Relative Humidity 15 to 90% RH Constant, 0 to 99% RH Intermittent
  • Relay Output Factory Set for Direct Acting
  • Resolution 1 ppm
  • Response Time <45 s to 90%
  • Sensor Life 5 Years
  • Sensor Type Electrochemical
  • Set Point Selectable 25, 60, or 150 PPM
  • Set Point Differential/Hysteresis 3 % scale
  • Storage Temperature, Max 68 °F
  • Storage Temperature, Min 32 °F
  • Switch Rating NO: 5 A @ 30 Vdc, 250 Vac; NC: 3 A @ 30 Vdc, 250 Vac
  • Switch Type SPDT NO/NC, Selectable
  • Temperature Effect ± 2% Over Range
  • Weight 1 lb
  • Zero Setting Adjustable Range 15 Turn Potentiometers

The Model CMS300 Carbon Monoxide Transmitter and Switch provides a field selectable current or voltage output that is proportional to the carbon monoxide concentration in underground parking garages, vehicle maintenance facilities, or mechanical rooms. An integral relay can be used for alarm conditions and is configured with preset jumper selectable ranges of 25, 60, or 150 PPM. Field calibration can be done by using Model GCK-200CO-2000CO2 calibration gas, Model A-507 calibration adapter, and the on board zero and span potentiometers.

Product Applications

  • Garage or loading dock ventilation
  • Vehicle maintenance facilities
  • Mechanical room monitoring
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 20ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration