Welcome to our new website, found an issue or bug? Please report it here

CCT-Series-Sig-Cond
DIN Rail Signal Conditioner Series with Model Specific Input Type
Models In Stock
- Voltage, Current, Frequency, Resistance, Potentiometer, Thermocouple, RTD and Strain Gage Input Modules
- Integrator Modules Convert Voltage or Current to Frequency
- Loop Powered Galvanic Isolator Provides 2 kVeff Isolation Between Input and Output
- Compatible with Standard 35 mm DIN Rail
CCT-Series-Sig-Cond
From
$
141.00
Models In Stock

Product Overview
- Approvals CE, UL
- Approvals Note Enclosure: UL 94 V-1, Terminal Housing: UL 94-2
- Bandwidth 1.5 Hz (-3 dB)
- Enclosure Ratings IP20, IP40
- Height 75 mm
- Isolation 2000 Vrms
- Materials Polycarbonate, RAL 7032
- Mounting DIN Rail 46277 and EN 50022
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -10 °C
- Output Value Process
- Power Consumption max 1.5 VA
- Serial Number Break Protection: Jumper selectable, upscale (>20 mA) or downscale (<4 mA)
- Storage Temperature, Max 80 °C
- Storage Temperature, Min -30 °C
- Supply Power Note 110 Vac (standard); 220 Vac or 24 Vdc (optional) (±10% tolerance on all power supplies)
- Wire Gauge 14 AWG
The CCT series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, temperature (thermocouple and RTD), and process transducers, and provide standard process outputs of either 0/4 to 20 mA, or 0 to 10 Vdc. The CCT series features a modern housing design, that is easily mounted on standard DIN rails. Connections are safely and securely made, with input and output connections on the opposite sides of the module.
Internal Design
The CCT series is designed using an internal plug-in three module system that provides flexibility in selecting and changing the power supply, input signal and output signal. The units are supplied with 110 Vac power standard, Consult sales for 220 Vac, and 24 Vdc power.
Isolation
The three internal modules in each signal conditioner (signal input, signal output and power supply) are isolated up to 2 kVeff.
Outputs
Each CCT series signal conditioner is available with current and voltage output (only one may be used at a time). Available output types include 4 to 20 mA or 0 to 20 mA (jumper-selectable) and 0 to 10 Vdc.
Standard outputs are linear and proportional to the signal input. Thermocouple input modules feature special circuitry to linearize the output to the actual temperature, and not to the non-linear signal produced by thermocouple sensors.
Specifications
Power: 110 Vac (standard); 220 Vac or 24 Vdc (optional) (± 10% tolerance on all power supplies)
Output: 4 to 20 mA and 0 to 10 Vdc standard; 0 to 20 mA via jumper select
Accuracy: ≠¤0.2% or ≠¤0.3,%, depending on the model
Response Time: ≠¤250 ms
Isolation: 2 kVeff
Ripple: ≠¤0.5%
Bandpass: 1.5 Hz (-3 dB)
Operating Ambient: -10 to 60°C (14 to 140°F)
Storage Ambient: -30 to 80°C (-22 to 176°F)
Temperature Coefficient: ≠¤0.015%/°C
Power Consumption: 1.5 VA max
Enclosure: Polycarbonate, RAL 7032; UL 94 V-1, IP40 protection
Terminal Housing: Polycarbonate, UL 94-2, IP20 protection
Max Wire Size: 4 mm² (14 AWG)
Dimensions: 75 H x 45 W x 110 mm D (2.95' x 1.77' x 4.33')
Weight: 270 g (0.6 lb)
Mounting: DIN rail 46277 and EN 50022 (35 x 7.5 mm)
Internal Design
The CCT series is designed using an internal plug-in three module system that provides flexibility in selecting and changing the power supply, input signal and output signal. The units are supplied with 110 Vac power standard, Consult sales for 220 Vac, and 24 Vdc power.
Isolation
The three internal modules in each signal conditioner (signal input, signal output and power supply) are isolated up to 2 kVeff.
Outputs
Each CCT series signal conditioner is available with current and voltage output (only one may be used at a time). Available output types include 4 to 20 mA or 0 to 20 mA (jumper-selectable) and 0 to 10 Vdc.
Standard outputs are linear and proportional to the signal input. Thermocouple input modules feature special circuitry to linearize the output to the actual temperature, and not to the non-linear signal produced by thermocouple sensors.
Specifications
Power: 110 Vac (standard); 220 Vac or 24 Vdc (optional) (± 10% tolerance on all power supplies)
Output: 4 to 20 mA and 0 to 10 Vdc standard; 0 to 20 mA via jumper select
Accuracy: ≠¤0.2% or ≠¤0.3,%, depending on the model
Response Time: ≠¤250 ms
Isolation: 2 kVeff
Ripple: ≠¤0.5%
Bandpass: 1.5 Hz (-3 dB)
Operating Ambient: -10 to 60°C (14 to 140°F)
Storage Ambient: -30 to 80°C (-22 to 176°F)
Temperature Coefficient: ≠¤0.015%/°C
Power Consumption: 1.5 VA max
Enclosure: Polycarbonate, RAL 7032; UL 94 V-1, IP40 protection
Terminal Housing: Polycarbonate, UL 94-2, IP20 protection
Max Wire Size: 4 mm² (14 AWG)
Dimensions: 75 H x 45 W x 110 mm D (2.95' x 1.77' x 4.33')
Weight: 270 g (0.6 lb)
Mounting: DIN rail 46277 and EN 50022 (35 x 7.5 mm)
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
Russell from
turns Pt thermometer into 0-10V signal
The low level output of a Pt thermometer will result in a staircase graph when used with an analog to digital converter with low resolution. Amplifying the output smooth's the graph, and increases the resolution very nicely.
Date published: 2016-08-23
Rated 5 out of
5
by
nafm from
easy to calibrate to my application
Replaced a unit that served well for almost 15 years..
Date published: 2017-09-03
Rated 5 out of
5
by
Purchasing Agent from
As desribed
Product arrived in a timely manner and as decribed
Date published: 2023-07-27
I am currently looking for a AC voltage signal conditioner, can this product be programmed to detect 0 to 11.34 Hz?
Thank you for your question. Unfortunately, it cannot. Frequency range is 20 hz-6 hz.
Date published: 2023-09-07