Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Vos commentaires sont importants, répondez à un sondage rapide commentaires sur le site web

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

AM-2250-Controller

Multi-Variable Controller pH, ORP, Contacting Conductivity, Flow

Modèles en stock
  • pH, ORP, conductivity & flow parameters available.
  • Highly visible back-lit LCD display.
  • Flexible and easy calibration, including multi-point conductivity calibration for acids and bases.
  • Three control relays for rising or falling processes.
AM-2250-Controller
Depuis $ 1,249.70
Modèles en stock
Multi-Variable Controller pH, ORP, Contacting Conductivity, Flow AM-2250-Controller AM-2250-Controller
loading all models
L'aperçu du produit
  • Additional Features 1 PID Control, Sensors Sold Separately
  • Calibration Note pH Calibration modes: Automatic or Manual 2 or 3 points; ORP Calibration modes: Manual 1 point; Conductivity Calibration modes: Up to 16 points; Flow Calibration modes: K factor input
  • Compliance ETL
  • Compliance Note ETL (US and Canada) and CE pending
  • Conductivity Measurement 0.055 to 500,000 µS/cm
  • Cutout Dimensions 5.4 x 5.4 in
  • Display Type LCD
  • Enclosure Ratings NEMA Type 4X
  • Flow Indication Note 0 to 999 in any units
  • Height 5.5 in
  • Input Range Note pH Sensor Input: -600 to +600 mV; ORP Sensor Input: -999 to +999 mV; Conductivity Sensor Input: 0 to 9999 Ω; Flow Sensor Input: 0 to 2000 Hz
  • Length 5 in
  • Mounting Orientation Panel Mount, Wall Mount
  • Number of Relays 3
  • Operating Humidity 0 to 90% RH
  • Operating Temperature, Max 120 °C
  • Operating Temperature, Min -20 °C
  • ORP Measurement Range -1000 to +1000 mV
  • Output Detail Two 4-20 mA outputs, Scalable 4-20mA with PID (Process), Scalable 4-20mA (Process or Temperature), Optically isolated. Max Load - 800 Ω
  • PH Measurement Range 0 to 14.00 pH
  • Power Consumption 0.2 A @ 115 Vac or 15 W
  • Process Temperature, Max -20 °C
  • Process Temperature, Min 70 °C
  • Relay Note 3 Dry contact relay with snubber circuit, 10A @ 120/240 VAC or 8A @ 30 VDC (Resistive Load), 5A @ 120/240 VAC or 4A @30 VDC (Inductive load) Relay Modes: Rising/Falling/In Range. Options: Relay Delay, Cycle, Overfeed Timer, Override, One relay can be triggered by temperature or flow totalizer.
  • Sensing Element 100/1000 Ω RTD, 300/3K Ω NTC or none
  • Sensing Element Note PH, ORP, Conductivity: 100, 1000 Ω, RTD 300, 3K Ω NTC or none
  • Sensor Type Note pH Sensor: 6-Wire Differential or Combination; ORP Sensor: 6-Wire Differential or Combination; Conductivity Sensor: 4-Wire contacting : Any cell constant between 0.01 and 100; Flow Sensor: Pulse output: Paddle-wheel, Magmete
  • Temperature Compensation Automatic: pH ;Automatic or Manual: Conductivity ;Display temperature: ORP ;Display Flow Totalizer: Flow
  • Temperature Measurement Note pH, ORP, Conductivity : -20 to 120 °C, Flow : Flow Totalizer 0 to 999 in any units
  • Weight 2 lb
  • Width 5.5 in
The AM-2250 series is built on the legacy of the Shark and 2200 controllers. Like its predecessors it is designed to be the most flexible, easy to use, and easy to see multi-parameter controller on the market.

Four Parameters
Select the parameter you wish to measure from the easy-to-use menu. Choose Conductivity, pH, ORP or Flow. The user interface was designed under the principle that the user should not need to read the manual.

Three Relays
The AM-2250 provides control of external devices using its three independent control and alarm relays. Each relay has adjustable high, low, and in range set-points, cycle timer with adjustable on and off times. This feature enables tighter control of batch processes by eliminating chemical overshoot. Third relay can be activated by temperature or flow totalizer reading as well.

Analog Outputs
The AM-2250 provides two isolated, independent and scalable 4-20 mA outputs.
One 4-20 mA output can be configured for PID control. The second 4-20mA output can be set for process or temperature.

Zero Cards
The AM-2250 comes complete. There are no extra costs associated with buying boards for different sensors, or buying components to achieve NEMA 4X.

Enclosure
The AM-2250 is packaged in a rugged NEMA 4X polycarbonate enclosure making it ideally suited for indoor and outdoor heavy-duty applications. A mounting kit is included for surface and panel mounting. The enclosure outline makes panel-mount cutouts simple. Pipe mounting kits are available.

One Big Display
The AM-2250 features a backlit LCD display can be seen from a distance. The keypad allows easy entry of menu items and numeric values.

Calibration
No other controller offers the same combination of flexibility and ease for calibration. The process value is visible during calibration so the user knows when it has settled down. Calibration of pH can be with 2 or 3 points. Calibration of conductivity can take as many as 16 points so acids and bases can be measured through their conductivity. All Calibration data is stored.

Accessories

Protector For R5 Sensors
C$68.73
0 In Stock
Protector For R8 Sensors
C$75.56
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Hello I need to implement dionized water in our process so ineed to implement a equiipment to verify if water has a good quality, someone recommended me the Item# AM-2250 but I want to ask you if so and what other accesories need to this process?

Asked by: Anonymous
Thank you for your inquiry. Please note that you may choose between measuring conductivity, pH, ORP, and flow rate with this device. The Accessories Tab will have the probe you can select for conductivity, pH ,or ORP available.
Answered by: Applications Engineer JJC
Date published: 2024-04-18
  • y_2025, m_4, d_18, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_AM-2250, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 32ms
  • QUESTIONS, PRODUCT
fr-CA
en
Enregistrer la configuration