Product Overview
- Accuracy ± 1 %
- Cable Length 5 m
- Calibration Note Line Resistance Compensation: 0.0 to 20.0 Ω
- Cell Constant K = 0.01, 0.1, 1, 10, Conductivity Electrode: K=1.0
- Conductivity Measurement 0.000 to 3.000, 30.00, 300.0 μS/cm
- Cutout Dimensions 93.5 x 93.5 mm
- Data Interface RS485
- Diameter 136 mm
- Display Type LCD
- EMC Standard EN 50081-1, EN 50082-1
- Enclosure Ratings IP65, NEMA Type 4X
- Frequency 1 to 999 hours 1 to 999 seconds(Frequency of Cleaning Time)
- Height 108 mm
- Impedance 600 Ω
- Materials Graphite
- Measurement Range Note Conductivity: 0.000 to 3.000, 30.00, 300.0 μS/cm Resistivity: 0.3 to 30.0 MΩcm TDS: 0.000 to 3.000, 30.00, 300.0 ppm, Test Range: 0 to 50.0 mS/cm
- Number of Relays 3
- Operating Humidity 10 to 95% RH
- Operating Temperature, Max 50 °C
- Operating Temperature, Min -10 °C
- Output Detail 4 to 20 mA/600 Ω
- Process Temperature, Max -0.5 °C
- Process Temperature, Min 130 °C
- Relay Note 3 SPST/250V 1A, Control Hysteresis Band: 0.1 to 10% FS
- Resistivity Measurement Range 0.3 to 30.0 MΩcm
- Resolution 0.001/0.01/0.1 μS/cm
- Temperature Accuracy ± 0.5 °C
- Temperature Resolution 0.1 °C
- Temperature Sensor Type 1000 Ω RTD
- Weight 1650 g
- Width 100 mm
The CDCN-961 conductance, resistance or total dissolved solids (TDS) controller is designed for inline monitoring of process solutions and water applications.
The CDCN-961 has simple menu driven programming for easy setup. Available relays can be programmed for control, alarm or as a calibration reminder. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the buffer solution resulting in a simple and straight forward system calibration.
Specifications
Conductivity Range:
0.000 to 3.000, 30.00, 300.0 µS/cm
0.000 to 3.000, 30.00, 300.0 mS/cm
Resistivity Range:
0.3 to 30.0 M?cm
3 to 300 M?cm
TDS Range:
0.000 to 3.000, 30.00, 300.0 ppm
0.000 to 3.000, 30.00, 300.0 ppt
Resolution:
0.001/0.01/0.1 µS/cm
0.001/0.01/0.1 mS/cm
0.1 M?cm
Accuracy: ±1% FS
Temperature Range: -0.5 to 130 °C (31.1 to 266 °F)
Temperature Resolution /Accuracy: 0.1 °C/ ±0.5 °C
Cell Constant: K = 0.01, 0.1, 1, 10
Line Resistance Compensation: 0.0 to 20.0 ?
Temperature Sensor: Pt1000
Signal Output/Load: 0/4 to 20 mA/600?
Output Interface: RS485
Relay Specification: 3 SPST/250V 1A
Control Hysteresis Band: 0.1 to 10% FS
Frequency of Cleaning Time: 1 to 999 hours 1 to 999 seconds
EMC Standard: EN 50081-1/EN 50082-1
Operation Temperature: -10 to 50 °C (14 to 122 °F)
Operation Humidity: 10 to 95%
Housing: NEMA 4X (IP65)
Dimensions: 100 W x 108 L x 136 Dia mm (3.93 x 4.25 x 5.35")
Panel Cutout: 93.5 L x 93.5 W mm (3.68 x 3.68")
Weight: 1650 g (58 oz)
Accessory:
Conductivity Electrode: K=1.0
Material: PPS/graphite
Test Range: 0 to 50.0 mS/cm
Temperature Range: 0 to 80 °C (32 to 176 °F)
Temperature System: Pt1000
Cable: 5 m (16.4')
The CDCN-961 has simple menu driven programming for easy setup. Available relays can be programmed for control, alarm or as a calibration reminder. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the buffer solution resulting in a simple and straight forward system calibration.
Specifications
Conductivity Range:
0.000 to 3.000, 30.00, 300.0 µS/cm
0.000 to 3.000, 30.00, 300.0 mS/cm
Resistivity Range:
0.3 to 30.0 M?cm
3 to 300 M?cm
TDS Range:
0.000 to 3.000, 30.00, 300.0 ppm
0.000 to 3.000, 30.00, 300.0 ppt
Resolution:
0.001/0.01/0.1 µS/cm
0.001/0.01/0.1 mS/cm
0.1 M?cm
Accuracy: ±1% FS
Temperature Range: -0.5 to 130 °C (31.1 to 266 °F)
Temperature Resolution /Accuracy: 0.1 °C/ ±0.5 °C
Cell Constant: K = 0.01, 0.1, 1, 10
Line Resistance Compensation: 0.0 to 20.0 ?
Temperature Sensor: Pt1000
Signal Output/Load: 0/4 to 20 mA/600?
Output Interface: RS485
Relay Specification: 3 SPST/250V 1A
Control Hysteresis Band: 0.1 to 10% FS
Frequency of Cleaning Time: 1 to 999 hours 1 to 999 seconds
EMC Standard: EN 50081-1/EN 50082-1
Operation Temperature: -10 to 50 °C (14 to 122 °F)
Operation Humidity: 10 to 95%
Housing: NEMA 4X (IP65)
Dimensions: 100 W x 108 L x 136 Dia mm (3.93 x 4.25 x 5.35")
Panel Cutout: 93.5 L x 93.5 W mm (3.68 x 3.68")
Weight: 1650 g (58 oz)
Accessory:
Conductivity Electrode: K=1.0
Material: PPS/graphite
Test Range: 0 to 50.0 mS/cm
Temperature Range: 0 to 80 °C (32 to 176 °F)
Temperature System: Pt1000
Cable: 5 m (16.4')
PDFs & Manuals