Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

We noticed you are from . Visit your local site for regional offers and live support.

OM-CP-PRTC110-Series

Differential Pressure and Thermocouple Temperature Data Logger

  • This product has been discontinued. Please see OM-CP-TC101A or OM-CP-PR2000 for a potential replacement.
  • 5 Year Battery Life
  • Wide Temperature Range
  • Accepts Thermocouple Types
OM-CP-PRTC110-Series
From $ 425.88
Differential Pressure and Thermocouple Temperature Data Logger OM-CP-PRTC110-Series OM-CP-PRTC110-Series
loading all models
Product Overview
  • Accuracy Detail Thermocouple Accuracy: ±5% FSR max at 25ºC over 1 year
  • Battery life up to 5 yr
  • Battery Size and Type 3.6V Li-ion
  • Baud Rate 57600
  • Calibration Digital calibration through software
  • Data Format atm, °C, Date and time, °F, inH2O, inHg, K, kPa, mmHg bar, MPa, Pa, PSIG, °R, Torr
  • Data Interface USB
  • Electrical Connection Note Thermocouple Connection:Female subminiature thermocouple connector Pressure Connections:REF and IN ports via 1⁄16" ID, 5⁄32" Max OD, polyurethane tubing
  • Height 0.8 in
  • Length 1.6 in
  • Memory Note 10,922 readings per channel; software configurable memory wrap
  • Number of Measurements 2
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -20 °C
  • Pressure, Max 4 psi
  • Pressure Measurement Range 0 to 2 inH2O
  • Real Time Recording The device may be used with PC to monitor and record data in Real-time
  • Relative Humidity 0 to 95% RH non-condensing
  • Resolution Temperature: 0.1°C, Pressure: 0.002 inH2O
  • Sampling Rate 2 Hz (2 updates/second)
  • Sampling Rate Note 2 Seconds to 24 hours
  • Sensor Type Diode temperature sensor, Piezoresistive Pressure Sensor
  • Software XP SP3/Vista/7 and 8
  • Start Modes Delayed Start, Immediate Start
  • Supply Power Type Battery
  • Temperature Measurement Range -20 to 80 °C
  • Thermocouple Resistance, Max 1000 Ω
  • Time Accuracy ±1 min/month (at 20 to 30°C)
  • USB Cable Length 6 ft
  • Weight 250 g
  • Width 2.7 in
The OM-CP-PRT110 is a differential pressure and temperature data logger, ideal for use in factory and laboratory applications. The OM-CP-PRT110 features a real-time clock module that extends the battery life to >2 years and allows for high speed downloads. This device will measure and record up to 10,922 measurements per channel. The storage medium is non-volatile solid state memory, providing maximum data security and stopped directly from your computer and its small size allows it to fit almost anywhere. The OM-CP-PRTC110 makes data retrieval quick and easy. Simply plug it into an available com port and our user-friendly software does the rest. The software converts a PC into a real-time strip chart recorder. Data can be printed in graphical and tabular format or exported to a text or Microsoft Excel® file.

Specifications
INTERNAL CHANNEL

Temperature Range: -20 to 80 °C (-4 to 176 °F)
Temperature Resolution: 0.1 °C
Calibrated Accuracy: ±0.5 °C (0 to 50 °C)

REMOTE CHANNELS
Thermocouple Types:
J, K, T, E, R, S, B, and N
Thermocouple Connection: Female subminiature thermocouple connector
Cold Junction Compensation: Automatic, based on internal channel
Maximum Thermocouple Resistance: 1000 Ω, <1000 Ω recommended
Pressure Range (Nominal): 0 to 2 inH2O or 0 to 5 inH2O (differential)
Pressure Range (Max): -2 to +4 inH2O and -2 to +8inH2O (differential)
Pressure Connections: REF and IN ports via 1/16' ID, 5/32' Max OD, polyurethane tubing
Pressure Resolution: 0.002 inH2O and 0.005 inH2O
Pressure Specified Accuracy: Nominal range at 25 °C
Combined Calibration Accuracy: ±0.5 °C FSR max at 0.25% over 1 year
Start Modes: Software programmable immediate start or delay start up six months in advance
Real-Time Recording: May be used with PC to monitor and record data in real time
Memory: 10,922 readings per channel; software configurable memory wrap
Reading Rate: 2 seconds to every 24 hours, selectable in software
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Battery Type: 3.6V lithium battery (included), user replaceable
Battery Life: 2 years (15 minute reading rate at 25 °C)
Data Format: Date and time stamped °C, °F, K, °R; inH2O,PSIG, inHg, mmHG, bar,
atm, Torr, Pa, kPa, and MPa
Time Accuracy: ±1 minute/month (at 20 to 30 °C)
Computer Interface: PC serial or USB (interface cable required); 57,600 baud
Software: XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -20 to 80 °C (-4 to 176 °F), 0 to 95% RH non-condensing
Dimensions: 68 H x 41 W x 20 mm D (2.7 x 1.6 x 0.8') plus connective tube
Enclosure: ABS plastic
Weight: 250 g (8.8 oz)
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 23ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 23ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration