Welcome to our new website, found an issue or bug? Please report it here
TXDIN401

Choose a Variant
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $159.53 |
5-9 | $151.55 |
10-24 | $148.36 |
25-49 | $141.98 |
50-99 | $138.79 |
100+ | $135.60 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Approvals | CE, RoHS |
CMRR | 50 to 60 Hz |
Electrical Connection | Screw Terminal |
Electrical Output | FS + 5°C |
Enclosure Ratings | IP20, NEMA |
Height | 90 mm |
Input Type | Thermocouple, RTD, Voltage |
Length | 64 mm |
Materials | Polycarbonate, Silicone |
Memory | 2624 Word |
Memory Note | Non-Volatile Memory (Circular Buffer) for Data Logging |
Mounting | DIN Rail Mount |
Number of Inputs | 3 |
Operating Temperature, Max | 85 °C |
Operating Temperature, Min | -40 °C |
Output Detail | Over-Range Output: fs + 5°C Under-Range Output: fs - 5°C |
Output Signal | Current |
Output Value | Process |
Relative Humidity | 30 to 90% RH (non condensing) |
Resolution | Output Resolution: 2 μA |
Response Time | 600 msec |
Sampling Rate | 300 milliseconds between updates |
Sensor Break Detection | 21 mA or 3.8 mA,Selectable |
Software | Windows® XP/7/8 (32-bit and 64-bit), Windows 10 (64-bit) |
Standard Limits of Error | 0.1% FS or 0.2 °C whichever is greater |
Storage Temperature, Max | 85 °C |
Storage Temperature, Min | -40 °C |
Supply Power Note | 2-wire loop powered; operating range 6 to 32 Vdc |
Supply Power Type | Loop Powered |
Supply Voltage | 6 to 32 Vdc |
Temperature Coefficient | <100 ppm |
Temperature Measurement Range | J: -200 to 1200°C, K: -260 to 1360°C , T: -260 to 400°C, E: -260 to 940°C,R: -40 to 1760°C, S: -40 to 1760°C (-40 to 3200°F), B: 40 to 1820°C, N: -260 to 1280°C,Pt100: -200 to 600°C, Ni100: 60 to 180°C |
Voltage Measurement Range | -10 to 70 mV |
Weight | 30 g |
Width | 18 mm |
Wire Code Option | 2 -, 3 - , 4- Wire |
See All Specs |
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 5 out of
5
by
Lee1023 from
Wireless configuration
We have used at least 20 of these since their introduction, and all are just fine! Love the price and have had no problems other than a loose circuit board in the programmer, fixed that and no problems whatsoever.
Date published: 2020-02-17
Rated 1 out of
5
by
ControlEngineer from
Programming is easy, but output is not correct
We bought 24 of these and a programmer, but 3 units show the same issues. A calibration curve with a known standard shows the output to be linear, but not according to the Type T thermocouple that it was programmed for. Programming for a different thermocouple type yielded the same output. Ice water shows up as -38C, room temperature at a balmy -17C. We will be returning all of them.
Date published: 2019-08-05