Welcome to our new website, found an issue or bug? Please report it here
DR-IO-ODC-RL-060
Voltage Conversion I/O Modules: Convert TTL Levels to PLC Levels and PLC Levels to TTL Levels

Choose a Variant
Voltage Measurement Range
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-9 | $65.45 |
10-24 | $62.18 |
25-49 | $60.87 |
50-99 | $58.25 |
100-199 | $56.94 |
200+ | $55.63 |
Product Specs
<< See all Product ModelsBrand |
![]() |
Approvals | CE, CSA, UL |
Height | 60 mm |
Input Type | Digital |
Isolation | 4000 Vrms |
Length | 80 mm |
Logic | N/A |
Mounting | DIN Rail 35 mm Standard “C” or as Top Hat |
Number of Inputs | 1 |
Operating Temperature, Max | 70 °C |
Operating Temperature, Min | -30 °C |
Output Signal | TTL |
Output Value | Process |
Storage Temperature, Max | 100 °C |
Storage Temperature, Min | -40 °C |
Voltage Measurement Range | N/A |
Voltage Output Range | 5 to 60 Vdc |
Width | 7.5 mm |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
Bairdf from
Low turn on current
I use these as solid state relays with the NI 9403 5V TTL DIO module. The problem I have always had is that the module only outputs 2mA per channel. These DR-IO modules let me go directly from the TTL signal to a 3A 208V powered device. If I need more than that I can used them to turn on a larger relay. The internal fuse make them a great space saver too.
Date published: 2016-02-16
Rated 5 out of
5
by
Joel Muniz from
Everything looks fine
Material arrived on time, good service and attention
Date published: 2023-10-05
Rated 5 out of
5
by
Kristina from
Quick Delivery
Fast delivery and exactly what we needed. Good quality.
Date published: 2023-05-11
Rated 1 out of
5
by
Anonymous from
output charge leak without control signal
These modules leak a low level charge without no control signal applied.
This is not noticeable with mechanical relays due to the low impedance which allows the charge to bleed without enabling the relay. However, with a sold state device with an high impedance will see a voltage on the input without a control signal applied.
Date published: 2020-10-29