Welcome to our new website, found an issue or bug? Please report it here

304-INC-DUAL-CLAD
Dual Mineral Insulated Thermocouple Cable
Models In Stock
- Mineral Insulated Cable, 4 Wire MIC with Mgo
- 4 Wire Dual Thermocouple MI Cable
- High Temperature Applications
- Weldable and Bendable
304-INC-DUAL-CLAD
From
$
3.81
Models In Stock

Product Overview
- Additional Features 1 Dual Elements
- Cable Length 25 ft
- Insulation MgO
- Process Temperature, Min 0 °C
- Resistance Note Resistance at 60°F Ω/dbl. ft
- Temperature Sensor Type Thermocouple
OMEGACLAD™ dual pair mineral insulated M.I. cable can be made into a single probe that enables transmission of a “split signal”. MgO style cable can be used to make nonexpendable thermocouple test sensors. This double signal 4 wire MIC can be attached to a controller and chart recorder at the same time to both monitor and control the same temperature location.
4 Wire Dual, 2 pair of TC conductors available in Standard Inch and Metric OD sizes:
0.375" (9.5 mm)
0.312" (7.9 mm) and 8.0mm
0.250" (6.4 mm) and 6.0mm
0.188" (4.8 mm) and 5.5mm or 4.5mm
0.125" (3.2 mm) and 3.0mm
0.062" (1.6 mm) 4 wire dual MIC with MgO
Technical Notes: OMEGACLAD™ wire can be made into a grounded junction probe and inserted into a pipe with compression fitting.
Insulation Compacted magnesium oxide is hygroscopic (absorbs moisture)
4 Wire Dual, 2 pair of TC conductors available in Standard Inch and Metric OD sizes:
0.375" (9.5 mm)
0.312" (7.9 mm) and 8.0mm
0.250" (6.4 mm) and 6.0mm
0.188" (4.8 mm) and 5.5mm or 4.5mm
0.125" (3.2 mm) and 3.0mm
0.062" (1.6 mm) 4 wire dual MIC with MgO
Technical Notes: OMEGACLAD™ wire can be made into a grounded junction probe and inserted into a pipe with compression fitting.
Insulation Compacted magnesium oxide is hygroscopic (absorbs moisture)
Model No. | Wire Calibration | Sheath Material | Sheath Diameter (in.) | Wall Thickness (in.) | Resistance at 60°F Ohms/ Dbl. ft. | Dia. of Wires (in.) | AWG Gage |
304-J-MO-062-DUAL 304-J-MO-125-DUAL 304-J-MO-188-DUAL 304-J-MO-250-DUAL | Iron- Constantan J | 304 Stainless Steel | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 3.6 0.88 0.36 0.22 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
INC-J-MO-062-DUAL INC-J-MO-125-DUAL INC-J-MO-188-DUAL INC-J-MO-250-DUAL | Iron- Constantan J | Inconel 600 | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 3.6 0.88 0.36 0.22 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
304-K-MO-062-DUAL 304-K-MO-125-DUAL 304-K-MO-188-DUAL 304-K-MO-250-DUAL | CHROMEGA™- ALOMEGA™ K | 304 Stainless Steel | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 6.0 1.5 0.59 0.37 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
INC-K-MO-062-DUAL INC-K-MO-125-DUAL INC-K-MO-188-DUAL INC-K-MO-250-DUAL | CHROMEGA™- ALOMEGA™ K | Inconel 600 | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 6.0 1.5 0.59 0.37 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
304-T-MO-062-DUAL 304-T-MO-125-DUAL 304-T-MO-188-DUAL 304-T-MO-250-DUAL | Copper- Constantan T | 304 Stainless Steel | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 3.0 0.75 0.298 0.19 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
INC-T-MO-062-DUAL INC-T-MO-125-DUAL INC-T-MO-188-DUAL INC-T-MO-250-DUAL | Copper- Constantan T | Inconel 600 | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 3.04 0.75 0.19 0.19 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
304-E-MO-062-DUAL 304-E-MO-125-DUAL 304-E-MO-188-DUAL 304-E-MO-250-DUAL | CHROMEGA™- Constantan E | 304 Stainless Steel | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 7.17 1.78 0.71 0.45 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
INC-E-MO-062-DUAL INC-E-MO-125-DUAL INC-E-MO-188-DUAL INC-E-MO-250-DUAL | CHROMEGA™- Constantan E | Inconel 600 | 0.062 0.125 0.188 0.250 | 0.010 0.018 0.025 0.036 | 7.17 1.78 0.71 0.45 | 0.010 0.020 0.032 0.040 | 30 24 20 18 |
PDFs & Manuals
Show Ratings & Reviews
CCan this thermocouple measure temperature as high as 800C?
The MI cable listed is rated for applications up to 1070 deg C. This wire can be welded in the field at one end to create a thermocouple and sense temperature.
Date published: 2022-11-10
Hello I need know if you have dual omegaclad mineral insulated cable in diameter 0.375" type J. I need 20 meters. Best regards
Hello,
Omega can manufacture Dual Omegaclad type J in a diameter of 0.375" as a custom part. Please send an e-mail to temp@omega.com if you'd wish to get more details on how to order this custom part number.
Date published: 2022-11-10