1-800-663-4209 | Vos commentaires sont importants, répondez à un sondage rapide commentaires sur le site web

HX200-Srs-TRH-Sig-Cond
Duct,Wall,Remote Mount Temp,Humidity,& Dewpoint Transmitters
Modèles en stock
HX200-Srs-TRH-Sig-Cond
Depuis
$
1,021.66
Modèles en stock

L'aperçu du produit
Afficher les notes et les avis
Rated 5 out of
5
by
Dean Friesen from
Excellent product.
Easy to incorporate in our system, operates flawlessly.
Date published: 2017-12-05
Rated 5 out of
5
by
humiditymeasurement from
can be connected to daq
got this for measuring inlet temperature and RH. can be connected to daq
Date published: 2022-09-12
Rated 5 out of
5
by
Copper from
works great in extreme environments
This instrument is more accurate than all of the other brands we have tried. It works great even through a high vibration environment where others fail
Date published: 2020-11-12
Rated 5 out of
5
by
rs1022 from
Works Great!
Just finished installing yesterday, easy set up. Being used in Dew Point mode, and switched over via internal dip switched. This unit is loop powered, so it will require a 24vdc separate power source.
Date published: 2018-08-21
Rated 4 out of
5
by
Fibreman12345 from
Good product
Using 4 to monitor dew point in compressed air system. Using a rs232 to ethernet comverter to pull data into database. Works great.
Improvements to get 5 stars
1. Make the sensor replaceable by adding a plug
2. Replace power plug with a 5 pin m12 so you do not have to drill a hole in the housing to get serial communication out of unit.
Date published: 2018-08-03
The manual indicates serial communications are possible but does not show the pin out to connect a cable. Could such documentation be added to the manual?
It's been one year and this still hasn't been added to the manual. As well, it's very unclear if the power connection can also be used to receive the 4-20 mA signal. The manual is poorly written.
Date published: 2022-10-14
Is a power supply provided with the unit?
Hi AndyInAA,
Thank you for the inquiry. Power supply is not included with the HX200 series.
Best regards
OMEGA
Date published: 2024-04-30
What is the connector for 4 tp 20 mA ? M12?
Hi D LeRoy,
Thank you for the inquiry. This unit has lead wire with stripped end connection. We offer field mountable M12 connectors which can be used.
Best regards
OMEGA
Date published: 2024-02-04
What is the recommended calibration method and calibration frequency for this unit?
Hi AnhT
Thank you for the inquiry. Suggested calibration interval is 1 year.
Best regards
OMEGA
Date published: 2020-08-29
Do you have the spec sheet showing the dimensions of this item? We would like to use this for our carbon capture system and would need the dimension details to include it in our CAD drawing.
Thank you for the request. Please forward this request to TEMP@OMEGA.COM.
Best regards
OMEGA
Date published: 2023-02-27
The cable from the sensor to the display box was pulled free and all wires were pulled out of the sockets. Can I get a wire diagram so I can re-connect the wires into the proper sockets?
Hi Greg,
Sorry to hear of the difficulty. Please forward email to TEMP@DWYEROMEGA.COM.
Best regards
OMEGA
Date published: 2024-03-25
I am trying to read through RS232. What is the command? How many Bytes supposed to return?
Hi KM OH,
Thank you for the inquiry. Please forward this question to TEMP@OMEGA.COM.
Best regards
OMEGA
Date published: 2024-02-22
Can the HX200HR be adjusted if the measurements are off? e.g. ours is reading 77.9% at 80%
Thank you for the inquiry. Calibration is performed via pc connection at the factory. 27 points are stored in the processor. This item needs to be sent in for calibration.
Best regards
OMEGA
Date published: 2020-08-31
RoHS 2015/863 - Voir le certificat
Approuvé CE
UKCA