Welcome to our new website, found an issue or bug? Please report it here

OM-CP-SHOCK-Series
Environmental and Tri-Axial Shock Data Loggers
Models In Stock
- Compact size
- 3-axis shock
- Temperature, humidity, pressure (OM-CP-ULTRASHOCK-A only)
- Fully configurable measurements
OM-CP-SHOCK-Series
From
$
1,003.71
Models In Stock

Product Overview
- Acceleration Range ± 15 g , ± 100 g , ± 300 g
- Approvals CE
- Battery life up to 3 mo
- Battery Size and Type Li-ion
- Calibration Digital calibration through software and automatically recorded within device
- Calibration Option NIST
- Data Interface USB
- Data protection Access by password
- Enclosure Ratings IP64
- Frequency Response >1000 Hz (15 g), >500 Hz (100 g, 300 g)
- Height 86 mm
- Humidity Range 0 to 95% RH non-condensing
- Length 43 mm
- Materials Aluminum
- Memory 3,593,358 Readings
- Memory Note 3,593,358 readings (598,893 per channel, all channels in use)
- Millivolt Range N/A
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -20 °C
- Pressure Type N/A
- Process Connection Size 1/4 in
- Process Connection Type N/A
- Real Time Recording May be used with PC to monitor and record data in real time at a 1 second sample rate
- Sampling Rate 1024 Hz (1024 updates/second)
- Software Standard Software version 4.2.15.0 or later Secure Software version 4.2.14.0 or later, Windows XP SP3/7/8/10
- Start Modes Delayed Start, Immediate Start
- Supply Power Type Battery
- Time Accuracy 10 seconds/month
- Weight 227 g
- Width 33 mm
The OM-CP-ULTRASHOCK-A is a 3-axis shock / acceleration data logger with additional channels for temperature, humidity and barometric pressure. Each of the six channels may be made active or inactive as needed. Disabling channels will provide additional storage to the enabled channels. The OM-CP-SHOCK300 is a 3-axis shock / acceleration data logger. Each of the three channels may be made active or inactive as needed. Disabling channels will provide additional storage to the enabled channels.
The OM-CP-ULTRASHOCK-A and OM-CP-SHOCK300 are specifically designed for documenting dynamic environments such as moving vehicles, trucks, containers, ships, etc. The device is also valuable in characterizing environments such as production and assembly lines of delicate electronics, IC fabrication, communications and computer components.
The OM-CP-ULTRASHOCK-A and OM-CP-SHOCK300 contain two separate accelerometers to provide high sensitivity and accuracy up to 15g or higher levels of shock monitoring up to 300g. One of three operating ranges must be chosen during setup for a logging session. Those ranges are +/- 15g (low g accelerometer), +/- 100g and +/- 300g (high g accelerometer).
OM-CP-SHOCK300 SpecificationsSHOCK | ||||
---|---|---|---|---|
Accelerometer Type | MEMS Semiconductor | |||
Acceleration Range (g) | ±15 g | ±100 g | ±300 g | |
Acceleration Resolution (g) | 0.02 g | 0.05 g | 0.2 g | |
Calibrated Accuracy (g) | ±0.3 g | ±2.0 g | ±6.0 g | |
Sampling Rate | 1000 Hz | |||
Accelerometer Freq. Resp. | >1000 Hz (15 g) >500 Hz (100 g, 300 g) | |||
Reading Rate | 1024 Hz to 5 minutes, selectable in software. |
OM-CP-ULTRASHOCK-A Specifications
TEMPERATURE | ||||
---|---|---|---|---|
Sensor | Semiconductor | |||
Range | -20 °C to +60 °C | |||
Resolution | 0.1 °C | |||
Accuracy | ±0.5 °C (+5 °C to +60 °C) | |||
HUMIDITY | ||||
Sensor | Capacitive Polymer | |||
Range | 0 %RH to 95 %RH | |||
Resolution | 0.1 %RH | |||
Calibrated Accuracy | ±3 %RH (±2 %RH typical at 25 °C) | |||
Specified Accuracy Range | +20 °C to +40 °C 25 %RH to 75 %RH | |||
PRESSURE | ||||
Sensor | Semiconductor Strain Gage | |||
Range | 100 mbar to 1300 mbar | |||
Resolution | 0.05 mbar | |||
Calibrated Accuracy | ±1.5 mbar at 25 °C at 750 mbar | |||
SHOCK | ||||
Accelerometer Type | MEMS Semiconductor | |||
Acceleration Range (g) | ±15 g | ±100 g | ±300 g | |
Acceleration Resolution (g) | 0.02 g | 0.05 g | 0.2 g | |
Calibrated Accuracy (g) | ±0.3 g | ±2.0 g | ±6.0 g | |
Sampling Rate | 1000 Hz | |||
Accelerometer Freq. Resp. | >1000 Hz (15 g) >500 Hz (100 g, 300 g) | |||
Reading Rate | 1024 Hz to 5 minutes for shock, selectable in software. Temperature, pressure and humidity sampled approx. every 2 seconds at intervals shorter than 2 seconds. Otherwise, sampled at the reading rate. |
GENERAL | ||||
---|---|---|---|---|
Memory | 3,593,358 readings (598,893 per channel, all channels in use) | |||
Start Modes | Software programmable immediate start or delay start, up to 6 months in advance | |||
Real Time Recording | May be used with PC to monitor and record data in real time at a 1 second sample rate | |||
Password Protection | An optional password may be programmed into the device to restrict access to configuration options. Data may be read out with the password. | |||
Calibration | Digital calibration through software | |||
Calibration Date | Automatically recorded within device | |||
Battery Type | Internal Lithium Ion pack, charger included | |||
Battery Life | 90 days typical at 64Hz rate | |||
Data Format | Date and time stamped gravities (g and mg), temperature (°C, °F, K, °R), humidity (%RH, mg/ml water vapor concentration), pressure (PSIA, inHg, mmHg, bar, atm, Torr, Pa, kPa, MPa) | |||
IP Rating | IP64 | |||
Time Accuracy | 10 seconds/month (at 0 °C to 50 °C) | |||
Computer Interface | USB-C cable required (included) 1MBaud | |||
Supported Software | Windows XP SP3/7/8/10 | |||
Software Compatibility | Standard Software version 4.2.15.0 or later Secure Software version 4.2.14.0 or later | |||
Operating Environment | -20 °C to +60 °C, 0 %RH to 95 %RH non-condensing | |||
Dimensions | 3.4 in x 1.7 in x 1.3 in (86 mm x 43 mm x 33 mm) | |||
Weight | 8 oz (227 g) | |||
Enclosure | Anodized aluminum | |||
Approvals | CE compliant EMC Directive 2014/30/EU RoHS Directive 2011/65/EU |
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Is there any filtering of samples occurring? Example Low Pass Butterworth or Bessel
Thank you for your question. Please e-mail your question to our Das Engr Dept -DAS@OMEGA.COM.
Date published: 2020-12-08
Does the OM-CP-Shock300 come with software and cable, or is tht sold seperately
Hello Writchie
Yes the logger already includes the software and cable.
Date published: 2020-03-26
Can data output be viewed live via USB connection? Is there a GUI provided for this?
Thank you for your question. Data can be viewed real-time on PC at 1 sec rate but, the primary function is stand-alone since it is monitoring shock in G-forces. Please download manual for your review.
Date published: 2022-12-03
How big are the mounting holes? Or what size screw should be used? How far apart are the two mounting holes?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2023-02-28
What is the size of the two mounting holes and the center-to-center distance?
Hi Erik,
OM-CP-Ultrashock-A
Mounting hole ID 0.20 inch diameter
Mounting holes ctr to ctr is 3.0 inch
Best regards
OMEGA
Date published: 2024-07-15
Hi, what is the minimum required usb speed?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2022-03-28