Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

We noticed you are from . Visit your local site for regional offers and live support.

Series-MTL5541

Galvanic Barrier, DIN Rail Mount, Plug-In, for Dwyer® Hazardous Areas

  • Easy snap-in installation for most DIN rails
  • Safe to use in hazardous locations
Series-MTL5541
From $ 1,154.75
Galvanic Barrier, DIN Rail Mount, Plug-In, for Dwyer® Hazardous Areas Series-MTL5541 Series-MTL5541
loading all models
Product Overview
  • Accuracy ± 15 µA
  • Applications Fluid Measurement and Control, Industrial and Manufacturing
  • Compliance FM, UL
  • Current Sink, Max 600 Ω max
  • Electrical Safety Vo= 28 V Io= 93 mA Po= 651mW Um= 253 RMS or DC. Weight: 5.3 oz (150 g)
  • Input Control Signal 16.2 Vdc
  • Isolation 250 V RMS, tested at 1500 V RMS minimum, between safe-area and hazardous-area terminals; 50 V between safe-area circuits and power supply
  • LED Indicators Green: Power indication
  • Load Resistance 0 to 360Ω @ 24 mA / 0 to 450Ω @ 20 mA
  • Mounting T-section 35 mm DIN rail to EN 50022
  • Operating Temperature, Max 140 °F
  • Operating Temperature, Min -6 °F
  • Output Detail Signal range: 4-20 mA; Under/over-range: 0-24 mA
  • Output Resistance >1 MΩ
  • Output Signal Current
  • Power Consumption 1 W
  • Relative Humidity 5 to 95% RH
  • Response Time 50 µs
  • Response Time Note Settles to within 10% of final value within 50 µs
  • Storage Temperature, Max 176 °F
  • Storage Temperature, Min -40 °F
  • Supply Power Type DC
  • Supply Voltage 20 to 35 Vdc
  • Temperature Drift < 0.8µA/°C
  • Terminal block up to 2.5 mm²
  • Weight 5.3 oz

The Series MTL5541 Galvanic Barrier provides intrinsically safe isolation for communication with Dwyer® transmitters approved for use in hazardous areas. This galvanic barrier eliminates the need for a high integrity earth ground required when using shunt type diode type safety barriers. DIN rail mounting and plug-in signal and power connectors simplify installation and maintenance.

Product Applications

  • Electrically isolates pressure and level transmitters from unregulated circuits for intrinsically safe applications
  • bvseo_sdk, java_sdk, bvseo-4.0.0