Product Overview
  • Accuracy ± 0.1 %
  • Accuracy Note 0.1% of span
  • Calibration 2 “Zero” DIP switches, 3 “Span” DIP switches and 2 fine tuning trimmers
  • Cold Junction Compensation ±0.9°C (±1.6°F) typical (3°C [5.4°F] for R and S) for 0 to 60°C
  • Diameter 44 mm
  • Dimensions Note 33 H x 44 mm diameter including the terminal block
  • Electrical Connection Screw Terminal
  • Electrical Output 4 to 20 mA
  • Height 33 mm
  • Housing Material Diecast zinc alloy
  • Humidity Range 5 to 95% RH, non-condensing
  • Input Type Thermocouple
  • Linearity <0.08%
  • Mounting Note 5 mm ID suitable for 8-32 screw
  • Mounting Screw Hole Diameter 5 mm
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min -20 °C
  • Output Detail 4 to 20 mA, 28 mA limited
  • Output Load (Vsupply - 10)/0.02
  • Probe Length 0 mm
  • Sensor Type Transmitter
  • Setup Controls 2 “Zero” DIP switches, 3 “Span” DIP switches and 2 fine tuning trimmers
  • Sheath Material N/A
  • Span, Min 600°C
  • Supply Power Effects <0.001%/1V
  • Supply Power Note 10 to 36 Vdc (24 Vdc recommended)
  • Supply Power Type DC
  • Supply Voltage 10 to 36 Vdc
  • Temperature Input Range R: 0 to 1750 °C;S: 0 to 1750 °C
  • Temperature Stability <0.01% of span/1°C
  • Weight 50 g

Description

Please check out Newest Released 2-wire Transmitters with Standard, FM & Hart Models Available TXUN Series for more advanced features and excellent usability.

TX250 Series
Thermocouple Input
The TX250 Series are non-isolated two-wire transmitter which convert the T/C thermoelectric voltage into a standardized load-independent, 4 to 20 mA process current.

The TX250 Series are housed in metal enclosures and fit into NB1 connection heads. The transmitter’s enclosure provides excellent RFI immunity.

The transmitter calibration is set by six dip-switches located behind the top cover. There are three basic models which cover the various T/C types. TX251 is for T/C types K, T and J TX252 is for type E and TX253 is for type R and S.

Dip-switch arrays select the T/C type, and set the "Zero" coarse level and the "Span" coarse range.

Zero and Span trimmers provide the fine tuning calibration.

TX254 RTD Input
The TX254 is a non-isolated two-wire transmitter which converts the measuring signal of a 3 wire 100 ohm Pt RTD into a standardized load-independent, 4 to 20 mA current which is linearly proportional to the measured temperature.

The TX254 transmitter is provided with excellent lead resistance compensation and Pt-100 linearization conforming to BS1904 and DIN 43760 characteristics (a = 0.00385). The transmitter calibration is set by six dip-switches located behind the top cover.

Three dip-switches set the lower measured coarse temperature and the other three dip-switches set the measured coarse temperature span.

Zero and Span trimmers provide the fine tuning calibration.
 
General Specifications
Output Current: 4 to 20 mA, 28 mA limited
Supply Voltage: 10 to 36 Vdc
(24 Vdc recommended)
Supply Variation Effect: <0.001%/1V change
Accuracy: Better than 0.1% of span
Load Resistance: Rmax () = (Vsupply - 10)/.02
Temperature Stability: <0.01% of span/1°C
Operating Temperature: -20 to 70°C (-4 to 158°F)
Humidity: 5 to 95% RH, non condensed
Housing: Die-cast zinc alloy
Mounting Holes: 5 mm ID suitable for 8-32 screw
Dimensions: 44 Dia x 33 mm H (1.7 x 1.3") including the terminal block.
Weight: 50 g (1.5 oz)

TX250 Thermocouple Input Specifications
Input:
TX251: thermocouple type K, T, J
TX252: thermocouple type E
TX253: thermocouple type R, S
Calibration: Two "Zero" DIP switches, three "Span" DIP switches and two fine-tuning trimmers
Cold Junction Error: ±0.9°C (1.6°F) typical (3°C [5.4°F] for R and S) for 0 to 60°C (32 to 140°F)
Linearity (refer to mV input): <0.08% of span
Note: Transmitters are linear to the mV input from the thermocouple, not to temperature.

 

TX250 RTD Input Specifications
Input: 3-wire Pt-100 according to BS 1904 and DIN 43760 characteristics
Input Span Range: 30 to 800°C
Input Zero Range: -50 to 200°C
Calibration: Three "Zero" DIP
switches, three "Span" DIP switches and two fine-tuning trimmers
Sensor Lead Resistance: 50 maximum (two ways)
Lead Compensation Error: <0.05°C/10 lead resistance
Sensor Excitation: <1 mA
Linearity: Better than 0.08% of span
 
 Model No.   Input Type   Span Range*   Minimum Span   Zero Offset Range  TX251 J -100 to 750°C 85°C -100 to 50°C -148 to 1380°F 155°F K -100 to 1350°C 105°C -100 to 100°C -148 to 2440°F 190°F T -100 to 400°C 100°C -100 to 100°C -148 to 750°F 180°F TX252 E -100 to 1000°C 75°C -100 to 30°C -148 to 1832°F 135°F TX253 R 0 to 1750°C 600°C 0 to 750°C 32 to 3180°F 1080°F S 0 to 1750°C 600°C 0 to 750°C 32 to 3180°F 1080°F TX254 RTD
100 ohm Pt
-50 to 750°C 30°C -50 to 300°C -58 to 1380°F 54°F


Transmitter Scaling Recommended (TX-SCALED) unless you have a source to scale the transmitter!
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 40ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration