1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback
DPG409
High Accuracy, Digital Pressure Gauge with Output & NEMA 4X Case
Models In Stock
- NEW RANGES! Sealed Gage, Compound Gage, Vacuum and, Barometric Ranges
- 5-Point NIST Traceable Calibration Included
- High 0.08% Accuracy on most Ranges
- Selectable 4 to 20 mA, 0 to 5V or 0 to 10V Analog Output
DPG409
From
$
1,115.15
Models In Stock

Product Overview
- Accuracy Class < 0.1%
- Accuracy Detail Accuracy (Combined Linearity, Hysteresis and Repeatability): ± 0.08% BSL (compound gauge calibrated in positive direction only)
- Battery life 9 mo
- Battery Size and Type Alkaline
- Cable Length 2.7 m
- Compliance CE
- Connection Location Lower
- Data Interface USB
- Data Interface Note USB connection for set-up, cable included
- Display Segment Height 25 mm
- Display Type 4 Digit LCD
- Display Type Note 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height.
- Electrical Output 4 to 20 mA
- Electrical Output Note User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types) Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 m
- Enclosure Material 316 Stainless Steel
- Enclosure Ratings IP65, NEMA Type 4X, Weatherproof
- Isolation between Case and Output Terminations, Min 100MΩ @ 50 Vdc
- Materials, Wetted 316 Stainless Steel
- Number of Batteries 2
- Number of Digits 4
- Operating Temperature, Max 66 °C
- Operating Temperature, Min -18 °C
- Output Signal Current, Voltage
- Pressure Accuracy ± 0.08 %
- Process Connection Size 1/4 in
- Process Connection Type NPT Male
- Sample/Display Rate 0.38 to 30 seconds
- Sample Display Rate Note User selectable from 0.38 to 30 sec. (preset to 1/sec)
- Sensor Dimension Note 72 to 89 mm L (2.8 x 3.5") below display
- Settable Parameters Backlight, Min, Max, Zero, Clear
- Software Settings Software Settings (via USB) Update Rate: 4 options, 10, 5, 2, 1 times per second Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _”
- Storage Temperature, Max 82 °C
- Storage Temperature, Min -40 °C
- Supply Power Note Battery Note:Two 1.5 V alkaline (C cell) included
- Supply Power Type Battery
- Thermal Effects Thermal Effects (Over Operating Range): Zero Balance: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span Span Setting: Ranges >5 psi: ± 0.3% span Ranges ≤5 psi: ± 0.5% span
- Weight 900 g
- Weight Note 900 g (2 lb) Typical depending upon configuration
- Wireless Option Specifications Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Outdoors (Line of Sight): Up to 120 m (400') Indoors/Urban: Up to 40 m (130') Included Software: Requires Windows® 7 (32 bit); XP or Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level
Omega’s DPG409 Series incorporates a rugged 316 Stainless Steel enclosure that is designed specifically for wash-down, sanitary, and marine applications. The large backlit LCD display features 1' high digits that make reading at distances up to 10.7 m (35') easy. DPG models are available with integral standard or sanitary pressure sensors that incorporate highly-stable silicon wafer technology which is micro-machined to precision tolerances and then has strain gages molecularly embedded. Standard features include: internal battery or external DC power supply operation, analog output, and user programmable alarms. The wireless transmitter option allows for remote monitoring, chart recording and data logging. A variety of user-configurable options and settings include: update rate, dampening, units, backlight, and auto-off.
Free Software for Set-up and Configuration via USB connection as well as Charting/Logging Software and drivers for wireless data.
To Order the optional Wireless Transmitter add suffix '-W', add $100 to price.
NOTE: Models with wireless option are approved for use in the U.S., Canada and Europe only
SPECIFICATIONS
CE Compliant: Meets EN61326-1: 2006 for industrial locations with analog output cables less than 30 m (98')
Accuracy (Combined Linearity, Hysteresis and Repeatability):
± 0.08% BSL (compound gauge calibrated in positive direction only)
Temperature:
Storage: -40 to 82°C (-40 to 180°F)
Operating: -18 to 66°C (0 to 150°F)
Thermal Effects (Over Operating Range):
Zero Balance:
Ranges >5 psi: ± 0.3% span
Ranges =5 psi: ± 0.5% span
Span Setting: Ranges >5 psi: ± 0.3% span
Ranges =5 psi: ± 0.5% span
Minimum Resistance Between Transducer Body and Any Wire: 100MO @ 50 Vdc
Pressure Cycles: 1 million minimum
Long Term Stability (1-yr): ± 0.1% FS typical
Analog Output: User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types)
Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc.
Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA
Analog Output
Cable: 2.7 m (8.9')
Accuracy: 0.08% typical
Overpressure: Gauge and sealed gauge
10 inH2O: 10 times span
1 psi: 6 times span
2.5 to 1000 psi: 4 times span
1500 to 5000 psi: 7250 psi max
Absolute/Barometric Ranges
5 psia: 6 times span
15 to 1000 psia: 4 times span
1500 to 5000 psi range: to 7250 psia
Containment Pressure: Gauge pressure
10 inH2O to 5 psi: To 1000 psi
15 to 1000 psi: To 3000 psi
1500 to 5000 psi: To 10,000 psi
Absolute/Barometric Pressure: 5 to 1000 psi: to 6000 psia
Display: 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height
Computer Interface: USB connection for set-up, cable included
Sample/Display Range: User selectable from 0.38 to 30 sec. (preset to 1/sec)
Power: Two 1.5 V alkaline (C cell) included.
Battery Life (Typical): Up to 9 months
Enclosure:
Material: 316 stainless steel and ABS center gasket
Finish: Brushed 316 stainless steel
Environmental Rating: Weatherproof, NEMA 4X (IP65)
Sensor Wetted Parts: 316L stainless steel
Pressure Connection: 1/4; -18 NPT male
Connection Location: Lower
Dimensions:
Display: 115 H x 89 W x 74 mm D (4.5 x 3.5 x 2.9')
Sensor: 72 to 89 mm L (2.8 x 3.5') below display
Weight: 900 g (2 lb) Typical depending upon configuration
Front Panel Functions
Backlight: Manually turns backlight on/off
Min/Max: Recalls min/max values
Zero/Clear: Zeros display or clears min/max
Software Settings (via USB)
Update Rate: 4 options, 10, 5, 2, 1 times per second
Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order
Lock: Allows the lock-out of front panel functions
Alarms: User selectable “High” and “Low” alarm limits (open collector)
Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min
Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging
Calibrate: Zero and Span
Overrange Indication: “_ _ _ _”
Wireless Option Specifications
Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec
Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz
RF Output: 10 dBm (10 mW)
Range of RF Link:
Outdoors (Line of Sight): Up to 120 m (400')
Indoors/Urban: Up to 40 m (130')
Included Software: Requires Windows® 7 (32 bit); XP or Vista
Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level
Read More
Free Software for Set-up and Configuration via USB connection as well as Charting/Logging Software and drivers for wireless data.
To Order the optional Wireless Transmitter add suffix '-W', add $100 to price.
NOTE: Models with wireless option are approved for use in the U.S., Canada and Europe only
SPECIFICATIONS
CE Compliant: Meets EN61326-1: 2006 for industrial locations with analog output cables less than 30 m (98')
Accuracy (Combined Linearity, Hysteresis and Repeatability):
± 0.08% BSL (compound gauge calibrated in positive direction only)
Temperature:
Storage: -40 to 82°C (-40 to 180°F)
Operating: -18 to 66°C (0 to 150°F)
Thermal Effects (Over Operating Range):
Zero Balance:
Ranges >5 psi: ± 0.3% span
Ranges =5 psi: ± 0.5% span
Span Setting: Ranges >5 psi: ± 0.3% span
Ranges =5 psi: ± 0.5% span
Minimum Resistance Between Transducer Body and Any Wire: 100MO @ 50 Vdc
Pressure Cycles: 1 million minimum
Long Term Stability (1-yr): ± 0.1% FS typical
Analog Output: User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required for all analog output types)
Note: Compound gauge ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc.
Set jumper to select current or voltage Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA
Analog Output
Cable: 2.7 m (8.9')
Accuracy: 0.08% typical
Overpressure: Gauge and sealed gauge
10 inH2O: 10 times span
1 psi: 6 times span
2.5 to 1000 psi: 4 times span
1500 to 5000 psi: 7250 psi max
Absolute/Barometric Ranges
5 psia: 6 times span
15 to 1000 psia: 4 times span
1500 to 5000 psi range: to 7250 psia
Containment Pressure: Gauge pressure
10 inH2O to 5 psi: To 1000 psi
15 to 1000 psi: To 3000 psi
1500 to 5000 psi: To 10,000 psi
Absolute/Barometric Pressure: 5 to 1000 psi: to 6000 psia
Display: 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height
Computer Interface: USB connection for set-up, cable included
Sample/Display Range: User selectable from 0.38 to 30 sec. (preset to 1/sec)
Power: Two 1.5 V alkaline (C cell) included.
Battery Life (Typical): Up to 9 months
Enclosure:
Material: 316 stainless steel and ABS center gasket
Finish: Brushed 316 stainless steel
Environmental Rating: Weatherproof, NEMA 4X (IP65)
Sensor Wetted Parts: 316L stainless steel
Pressure Connection: 1/4; -18 NPT male
Connection Location: Lower
Dimensions:
Display: 115 H x 89 W x 74 mm D (4.5 x 3.5 x 2.9')
Sensor: 72 to 89 mm L (2.8 x 3.5') below display
Weight: 900 g (2 lb) Typical depending upon configuration
Front Panel Functions
Backlight: Manually turns backlight on/off
Min/Max: Recalls min/max values
Zero/Clear: Zeros display or clears min/max
Software Settings (via USB)
Update Rate: 4 options, 10, 5, 2, 1 times per second
Units: psi, inHg, inH2O, bar, mbar, hPa units; must be specified at time of order
Lock: Allows the lock-out of front panel functions
Alarms: User selectable “High” and “Low” alarm limits (open collector)
Backlight: On/off, 10 sec, 30 sec, 1 min, 5 min
Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging
Calibrate: Zero and Span
Overrange Indication: “_ _ _ _”
Wireless Option Specifications
Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec
Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz
RF Output: 10 dBm (10 mW)
Range of RF Link:
Outdoors (Line of Sight): Up to 120 m (400')
Indoors/Urban: Up to 40 m (130')
Included Software: Requires Windows® 7 (32 bit); XP or Vista
Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level