Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

OS-HFV50-601-LT

60:1 FOV, 0°C to 1300°C

$950.80

Item# OS-HFV50-601-LT

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $950.80
5-9 $903.26
10-24 $884.24
25-49 $846.21
50-99 $827.20
100+ $808.18

In Stock

Lead Time (If not in stock): 10 weeks

Product Specs

<< See all Product Models
Brand
Additional Features 1 Simultaneous analog and digital outputs
Cable Length 3 m
Cable Length Note 3 m (standard, 4-cores), 5 m/10 m
Current Draw 100 mA
Data Interface USB
Emissivity Note 0.100 to 1.000, in 0.001 increments
Emissivity, Max 1
Emissivity, Min 0.1
Enclosure Ratings IP64
Field of view 60:1
Intrisically Safe No
Loop Resistance, Max 500 Ω
Operating Temperature, Max 70 °C
Operating Temperature, Min 0 °C
Output Signal Current
Process Temperature, Max 900 °C
Process Temperature, Min 0 °C
Relative Humidity Note 10 to 95%, non-condensing
Relative Humidity, Max 95%
Relative Humidity, Min 10%
Repeatability ± 0.5% of reading or ± 1°C
Response Time 150 ms
Response Time Note 150 ms ((95% signal))
Sensor Diameter 59.5 mm
Sensor Length 110 mm
Spectral Response, Max 14 μm
Statistics Average, Peak Hold, Valley Hold
Storage Temperature, Max 80 °C
Storage Temperature, Min -20 °C
Supply Power Note 24 VDC ± 20%
Supply Voltage 24 Vdc
Temperature Resolution 0.1 °C
Weight 500 g
Weight Note 500g (without cable)
See All Specs Show Less
60:1 FOV, 0°C to 1300°C OS-HFV50-601-LT OS-HFV50-601-LT
Rated 4 out of 5 by from Good device, bad documentation The product works well, but the operator's manual contains a MAJOR error in the section on how to set up the sensor. The manual says to enter setup mode by pressing and holding both buttons. However, pressing and holding down, then pressing up resets the sensor, erasing all settings. Setup must be entered by pressing and holding up, then pressing down. This is not explained in the manual. It took 6 calls to Omega over two days to even explain to a tech support person what the error was. I hope that it will be corrected in future documentation.
Date published: 2021-02-09
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_OS-HFV50-601-LT, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT
en-US
en
Save Configuration