Welcome to our new website, found an issue or bug? Please report it here

FP2540-Series
All Metal Hot Tap Option Paddlewheel Flow Meter
- Rugged 316 Stainless Steel Construction
- Flow Rates as Low as 0.3 fps
- Installs in a Variety of Pipe Sizes
- No Magnets in Process Fluid
FP2540-Series
From
$
941.06

Product Overview
- Accuracy ± 1 %
- Approvals CE
- Cable Length 25 ft
- Cable Length Note 7.6 m (25') 305 m (1000') maximum
- Cable Type Twisted Pair with Foil Shield
- Electrical Output Open Collector, Sinking
- K-Factor 15 Hz/fps
- Linearity Error ±1%
- Material Construction Option N/A
- Materials, Wetted 316 Stainless Steel, FKM, PEEK
- Media Compatibility Liquids
- Mounting Orientation N/A
- Operating Pressure, Max 250 psi
- Operating Pressure, Min 0 psi
- Operating Temperature, Max 149 °C
- Operating Temperature, Min -46 °C
- Output Detail Output Signal: Open collector, sinking, Output Frequency: 15 Hz per fps
- Pipe Connection Note Hot Tap
- Pipe Size, Min 1.5 in
- Pressure Type Gauge
- Process Connection Size 1 1/2 in
- Process Connection Type NPT Male
- Process Temperature, Max 82 °C
- Process Temperature, Min 0 °C
- Process Temperature Note With standard FKM O-rings: 250 psi @82°C (180°F)
- Repeatability Error ±0.5%
- Supply Voltage 5 to 24 Vdc
- Velocity, Max 20 ft/s
- Velocity, Min 0.3 ft/s
- Weight 0 kg
The FP-2540 and FP-3-1500 Series offer the added strength and corrosion resistance of stainless steel for applications requiring low velocity measurement. Unique internal circuitry eliminates the need for magnets in the process fluid, enabling lower flow measurement while maintaining the advantages of insertion-type sensor design. The sensor’s unique rotor/bearing design offers low flow measuring capability with increased reliability.
SPECIFICATIONS
Output Signal: Open collector, sinking
Output Frequency: 15 Hz per fps
Operating Range: 0.3 to 20 fps
Pressure/Temperature: With standard
FKM O-rings: 250 psi @ 82°C (180°F)
Power Requirements: 5 to 24 Vdc
Pipe Size Range:
FP-2540: 1.5 to 24"
FP-3-1500-2X: 1.5 to 36"
Repeatability: ±0.5% of full range
Linearity: ±1% of full range
MATERIALS
Sensor Fitting: 316 SS
O-rings: FKM
Rotor: CD4MCu
Rotor Bearings: PEEK
Cable Type: Twisted pair with foil shield
Cable Length: 7.6 m (25'); 305 m (1000') max
SPECIFICATIONS
Output Signal: Open collector, sinking
Output Frequency: 15 Hz per fps
Operating Range: 0.3 to 20 fps
Pressure/Temperature: With standard
FKM O-rings: 250 psi @ 82°C (180°F)
Power Requirements: 5 to 24 Vdc
Pipe Size Range:
FP-2540: 1.5 to 24"
FP-3-1500-2X: 1.5 to 36"
Repeatability: ±0.5% of full range
Linearity: ±1% of full range
MATERIALS
Sensor Fitting: 316 SS
O-rings: FKM
Rotor: CD4MCu
Rotor Bearings: PEEK
Cable Type: Twisted pair with foil shield
Cable Length: 7.6 m (25'); 305 m (1000') max
PDFs & Manuals
Show Ratings & Reviews
Hello , can use this model with fule as diesel ..
Thank you for your inquiry. The paddle wheel sensor can be used to measure fuel, please note that it is calibrated for water. A field calibration will have to be performed to adjust the K-factor for this other liquid.
Date published: 2023-10-26
Do you provide an added component whereby to convert the open collector pulse to 4-20 maDC? If not can you suggest an appropriate one?
Thank you for your inquiry. I believe you are looking for a signal conditioner. You can look at part number DRST-FR.
Date published: 2019-11-16