Product Overview
- Accuracy ± 0.005 %
- Analog-to-Digital Technique Dual slope
- CMRR 120 dB
- Common Mode Voltage 1500 Vp per HV test
- Cutout Dimensions 1.772 x 3.622 in
- Display Note Red 6-digit, 14-segment, 13.7 mm (0.54") high; 4 alarm indicators
- Display Type LED
- Form factor 1/8 DIN
- Height 1.89 in
- Input Configuration Front panel buttons or via your computer
- Input Range Note 0 to 100 mV, 0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, 0 to 100V, ± 50 mV, ± 500 mV, ± 5V, ± 50V, 0 to 20 mA, 4 to 20 mA
- Input Type Single Ended, Strain
- Internal Resolution 15 bit
- Length 6.5 in
- Materials Polycarbonate
- Measurement Type Strain
- Mounting Panel
- NMRR 60 dB
- Number of Digits 6
- Number of Inputs 1
- Offset Adjustment 0 to 999999 or 0 to - 99999 programmable
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Polarity Unipolar/Bipolar, programmable
- Power Consumption 10 W
- Power Consumption Note 6 W Nominal, 10 W
- Reading Rate 3/s or 13/s, 60 Hz; 3/s or 12/s, 50 Hz
- Relative Humidity 95% RH non-condensing
- Resolution 15-bit
- Sampling Rate 13 Hz (13 updates/second)
- Sensor Break Protection Up-scale or down-scale, programmable
- Sensor Excitation 10 V at 30 mA; 24V at 25 mA
- SetPoint Outputs 4 Isolated Open Collector; Rated 150 mA at 1V Sink, 30V Open
- Span Adjustment 0.00001 to 500,000, programmable
- Span Temperature Coefficient ± 20 ppm
- Step Response 1 s to 99.9%
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -40 °C
- Warm Up Time 50 min
- Weight 574 g
- Width 3.78 in
The OMEGA ® DP41-S indicators offer exceptional performance in a strain gage meter. The DP41-S has standard built-in excitation. The input range is selected via internal jumpers, and scaling to engineering units is performed using the front keypad. The DP41-S accepts strain gage bridge sensors and ratiometric voltage measurements. Programming the DP41-S is accomplished through the five front panel keypads. If the optional RS-232 or RS-485 communications are installed, the operator can remotely set all display parameters.