RAT-TJ

High Temp Thermocouple with Ceramic Sheath and Lead Wires

Models In Stock
  • NHX Standard Ceramic Connector Rated to 650°C (1200°F)
  • HSTW Standard Connector Liquid Crystal Polymer Rated to 260°C (500°F)
  • Up to 1650°C (3000°F) Rating
  • Oxidizing or Reducing Atmospheres
RAT-TJ
From $ 573.13
Models In Stock
High Temp Thermocouple with Ceramic Sheath and Lead Wires RAT-TJ RAT-TJ
loading all models
Product Overview
  • Cable Length 40 in
  • Color Code Standard ANSI
  • Insulation Note 1m (40") 24 AWG (0.020"); Solid Braided Fiberglass; Insulated Lead Wire
  • Junction Type Ungrounded
  • Number of Wires 2
  • Probe Diameter 0.25 in
  • Probe Type Rugged Transition Joint High-Temperature Thermocouple Probe
  • Process Temperature, Max 1650 °C
  • Process Temperature, Min 0 °C
  • Sheath Material Ceramic
  • Temperature Probe Style Extreme Temperature Probe
  • Temperature Sensor Type Thermocouple
  • Wire Type Solid
Type R, S, or B Platinum Thermocouple enclosed in a high purity alumina protection tube. Elements are insulated by a double bore high-purity hardfired alumina insulator.

View the Thermocouple Accuracy and Color Code charts
Rated 5 out of 5 by from High quality B type thermocouple This thermocouple has great quality and can be used at critical conditions.
Date published: 2023-06-02
  • y_2025, m_2, d_21, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_BAT-TJ36-24-12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Hello, what is the type of threads that are used on the mounting fitting (model no. SSLK-38-14 & SSLK-38-14)? E.g., NPT?

Asked by: Aero_CO
Thank you for your inquiry. SSLK-38-14 has a 1/4" NPT male.
Answered by: NorwalkAE_SP
Date published: 2024-11-14

Hello, It is possible this probe would function at -60degC?

Asked by: Luna
Thank you for your inquiry. Unfortunately, these probes are not rated for measuring -60degC.
Answered by: NorwalkAE_SP
Date published: 2023-10-31
  • y_2025, m_2, d_21, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_BAT-TJ36-24-12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 29ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration