Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

RHB-CAC1S-Series

Compressed Air Dew Point Monitor

  • NIST Traceable
  • +/- 0.2 deg C
  • Virtually Maintenance Free
  • Easy to Install
RHB-CAC1S-Series
From $ 7,926.75
Compressed Air Dew Point Monitor RHB-CAC1S-Series RHB-CAC1S-Series
loading all models
Product Overview
  • Alarm Audible: >98 dB @ 2' ; Relay: 1 form “C”, non-latching; 10 A @ 240 Vac, 8 A @ 24 Vdc, 1 ⁄2 hp @ 240 Vac ; Visual: Flashing “ALARM” message
  • Dew/Frost Point Accuracy 0.2°C (± 0.5°F)
  • Dew/Frost Point Temperature Max 50 °C
  • Display Type LED
  • Electrical Output 4 to 20 mA
  • Enclosure Aluminium
  • Enclosure Ratings IP55, NEMA Type 12
  • Measurement Type Dew Point
  • Mounting Space-Saving Wall Mount
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Output Detail 4 to 20 mA (0 to 5 Vdc), -50 to 50°C (-58 to 122°F) or -60 to 75°C (-76 to 167°F)
  • Process Connection Size 1/4 in
  • Process Connection Type Compression Fitting
  • Process Temperature, Max 50 °C
  • Sample Flow Rate 0.5 to 5.0 scfh, Integral flow meter
  • Sample Pressure 0 to 150 psig (higher pressures available, consult Engineering Department)
  • Supply Voltage 90 to 250 Vac
  • Temperature Accuracy ± 0.2 °C
  • Temperature Accuracy Note ± 0.2 °C (± 0.5 °F)

Description

These compressed air dewpointmonitors have been designed tooffer the highest level of reliabilityand accuracy available in suchsystems. They are fully NISTtraceable and employ a chilledmirrorsensor, the most accuratedewpoint sensing scheme available,to deliver consistent drift-freemeasurements without regularcalibrations or sensor replacement.
These compressed air monitors arecomplete dewpoint measuringsystems. The ruggedized aluminumNEMA 12 (IP55) enclosure housesthe sensor, control circuitry(including flow control) and is easilywall mounted to conserve space.Only the sample line and powerconnection are needed for thesystem to be operational.
The monitors also offer aprogrammable automatic balancecontrol (ABC) cycle that corrects forthe light-reducing effects of mirrorcontaminates and allows forcontinuous monitoring and virtuallymaintenance-free operation.

Specifications:
DEW/FROST POINT RANGE
Two-Stage (S2): -40 to 50°C (-40 to 122°F)
Three-Stage (S3): -60 to 50°C (-76 to 122°F)
Dew/Frost Point Accuracy: 0.20°C (± 0.5°F)

FUNCTIONALITY
Power: 90 to 250 Vac, 50 to 400 Hz
Operating Temperature: 0 to 50°C (32 to 122°F)
Sample Connection: 1/4" compression fitting
Sample Flow Rate: 0.5 to 5 SCFH integral flowmeter
Sample Pressure: 0 to 150 psig
(higher pressures available, consult Engineering Department)
Output: Analog: 4 to 20 mA (0 to 5 Vdc), 50 to 50°C (-58 to 122°F) or
-75 to 75°C (-103 to 167°F)
Compliance: 9.0 Vdc, 450 .
Display: Red LED, 0.5" tall 8-digit alphanumeric

ALARM:
Audible: >98 dba @ 2'
Relay: 1 Form C, non-latching 10 A @ 240 Vac, 8 A @ 24 Vdc, 1/2 HP @ 240 Vac
Visual: Flashing “ALARM” message
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 12ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration