Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

TX1500-Srs-Transmitters

Isolated 4 to 20 mA Transmitters for Demanding Applications

TX1500-Srs-Transmitters
From $ 370.00
Isolated 4 to 20 mA Transmitters for Demanding Applications TX1500-Srs-Transmitters TX1500-Srs-Transmitters
loading all models
Product Overview
  • Approvals RoHS 2 Compliant
  • Compliance 9 to 50 Vdc
  • Diameter 74 mm
  • Electrical Connection Screw Terminal
  • Electrical Output 4 to 20 mA
  • Enclosure Ratings IP66, NEMA Type 4X
  • Height 53 mm
  • Hysteresis ± 0.1%
  • Isolation 1500 Vrms
  • Long Term Stability ± 0.2% of zero suppression(6-month)
  • Materials Zamak Zinc Alloy, Fluorosilicone
  • Mounting Rail Mount
  • Number of Wires 2
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Output Signal Current
  • Power Supply Rejection 0.01% of span/V
  • Protection Termination Protection: Standard: Screw terminal barriers plus barrier strip cover
  • Relative Humidity 0 to 100% (sealed case)
  • Repeatability ± 0.1%
  • Response Time 400 ms
  • Shock 55 g, half sine, 9 to 13 ms duration
  • Span Error ± 0.2% of span, Due to 50°C Change in Transmitter Temperature
  • Storage Temperature, Max 125 °C
  • Storage Temperature, Min -55 °C
  • Supply Power 9 to 50V
  • Supply Power Type Loop Powered
  • Turndown Ratio 10:1
  • Vibration 1.52 mm (0.06") double amplitude, 10 to 80 Hz cycled
  • Water tight Proof Pressure 5 psi
  • Weight 380 g
  • Zero/Balance Error ± 0.2% of zero suppression, Due to 50°C Change in Transmitter Temperature
Unmatched Electrical Performance
Two-wire Operation Power is obtained directly from the 4 to 20 mA loop, with no need for separate power input. This simplifies field wiring and eliminates the possibility of noise pickup from power lines.

Isolation to 1500 V rms (2100 Vp)
This exceptionally high CMV rating from the input to the case or output eliminates the possibility of electrical ground loops between the signal source and the receiver. It also provides a high degree of protection for the receiver against electrical hazards, such as accidental contact between the signal source and an AC power line.

Turndown Ratio
Turndown ratio is defined as zero suppression divided by span. The exceptionally high 10:1 turndown ratio possible with the TX1500 Series indicates that wide zero offset can be combined with narrow signal span for closed loop control at high gain. The signal span can also be wide for control of batch operations, where a wide range of signal levels may be encountered over the entire batch cycle.

High Overvoltage Protection
Overvoltage of 120 Vac may be applied across the input or output leads for 1 minute in case of all models with voltage or thermocouple input. Reverse polarity of 400 Vp may be applied across the output leads indefinitely. These exceptionally high NMV overvoltage ratings provide further protection against possible electrical faults and wiring errors.

For complete product specifications see the detailed spec sheet
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 27ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration