1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback
LC8400
Large 2.5 in to 3.13 in ID, Through-Hole, Compression Load Cells
Models In Stock
- 5 Point NIST Traceable Calibration with
- 59 kOhm Shunt Cal Data
- 3.13, 4.00 and 4.50' OD Sizes
- Large I.D. Application
LC8400
From
$
764.34
Models In Stock

Product Overview
- 5-Point Calibration 0%, 50%, 100%, 50%, 0%
- Accuracy ± 0.5 %
- Cable Length 5 ft
- Calibration Option 5 POINT NIST
- Electrical Connection Cable
- Electrical Output 2 mV/V
- Force Type Compression
- Hysteresis ± 0.5%
- Input Resistance 360 Ω min
- Linearity ± 0.5%
- Load Cell Type Through Hole
- Materials 17-4 PH Stainless Steel
- Operating Temperature, Max 121 °C
- Operating Temperature, Min -54 °C
- Output Resistance 350 ± 5 Ω
- Overload, Max 300% FS
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Repeatability ± 0.5%
- Safe Overload 150% FS
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect ± 0.018% rdg/°C
- Thermal Zero Effect ± 0.009% FSO/°C
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error ± 2%
The LC8313, LC8400 and LC8450 Series Donut Load Cells are a space saving solution to applications requiring a large through-hole with limited space. With their rugged construction and design, these load cells are ideal for applications such as loading forces on large bolts or other suspended load applications. This series, with its all stainless steel construction and environmental protection, has proven its reliability in tough industrial applications.
SPECIFICATIONS
Output: 2 mV/V nominal
Input: 10 Vdc (15V max)
Accuracy: ± 0.5%, linearity, hysteresis and repeatability combined
Zero Balance: ± 2.0% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ± 0.009% FSO/°C
Span: ± 0.018% rdg/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Deflection: 0.076 mm (0.003") nominal
Input Resistance: 360 ? minimum
Output Resistance: 350 ± 5 ?
Construction: 17-4 PH stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable
Read More
SPECIFICATIONS
Output: 2 mV/V nominal
Input: 10 Vdc (15V max)
Accuracy: ± 0.5%, linearity, hysteresis and repeatability combined
Zero Balance: ± 2.0% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ± 0.009% FSO/°C
Span: ± 0.018% rdg/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Deflection: 0.076 mm (0.003") nominal
Input Resistance: 360 ? minimum
Output Resistance: 350 ± 5 ?
Construction: 17-4 PH stainless steel
Electrical: 1.5 m (5') 4-conductor shielded cable
PDFs & Manuals