Product Specs

<< See all Product Models
Brand
A/D Conversion Dual slope
Accuracy ± 0.5 °C
Accuracy Note ±0.5°C temperature; 0.03% rdg
Alarm modes Band, High/Low, Latch/Unlatch, Normally Open/Closed, Process/Deviation
Common Mode Rejection 120 dB
Control Mode Reverse (heat) or direct (cool)
Current Measurement Range 0 to 20 mA
Data Interface RS232, RS485, RS422
Data Interface Note Ethernet : Standards compliance IEEE 802.3 10Base-T Supported Protocols : TCP/IP, ARP, HTTPGET RS232/RS422/RS485/MODBUS : Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status. RS485 : Screw terminals
Decimal Selection 0, 0,001, 0,01, 0,1
Digital Filter Programmable
Display Color Red, Green, Amber
Display Size 57.2 mm (2.25 in)
Display Type 4 Digit, 7 Segment LED
Display Type Note 4-digit or 6-digit, 7-segment LED 57.2 mm (2.25") or 101.6 mm (4.00") red, green and amber programmable colors for process variable, set point and temperature units
Electrical Connection Screw Terminal
Enclosure Ratings IP65, NEMA Type 4
Excitation Voltage Note Optional in Place of Communication
Impedance Input 10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc
Input Configuration Single-ended
Input Type Themocouple, RTD, Current, Voltage
Isolation Power to Input/Output: 2300 Vac per 1 min test (RS232/485, input or output) Between Inputs: 500 Vac per 1 min test
Normal Mode Rejection 60 dB
Offset Adjustment -1999 to +9999
Operating Temperature, Max 40 °C
Operating Temperature, Min 0 °C
Polarity Unipolar
Power Consumption 22.5 W
RTD Type 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; α= 0.00385 or 0.00392
Reading Rate 3 samples/sec
Relative Humidity 90% RH non-condensing
Resolution 1°/0.1°; 10 µV process
Sensor/Transmitter Power 24 Vdc @ 25 mA
Set Point Adjustment -1999 to 9999 counts
Span Adjustment 0.001 to 9999 counts, programmable
Step Response 0.7 sec for 99.9%
Supply Power Note 100 to 240 Vac ±10%, 50/60 Hz
Supply Voltage 100 to 240 Vac
Temperature Stability RTD: 0.04°C/°C;Thermcouple @ 25°C (77°F): 0.05°C/°C—cold junction
Thermocouple Lead Resistance, Max 100 Ω
Thermocouple Type J, K, T, E, R, S, B, C, N, L
Voltage Measurement Range 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc
Warm-Up to Rated Accuracy 60 min