Welcome to our new website, found an issue or bug? Please report it here

PRS-3-100-M12
M12 Connector RTD Probes with Class A Accuracy 3-A Sanitary
Models In Stock
- Pt100 Class A Sensor with M12, 4-Pin Connection Allows for Quick and Easy Installation. An M12 Extension Cable is Required for Installation.
- 3-A Approved Design, Flanges conform to ASME-BPE-2007
- Can Be Used In Sanitary, Hygienic, and Clean-In-Place Food, Dairy, Beverage and BioPharmaceutical Applications
- Wetted Surfaces are 316L Stainless Steel With a Surface Finish = 32 Microinches or Better
PRS-3-100-M12
From
$
230.09
Models In Stock

Product Overview
- Accuracy Class A
- Electrical Connection M12 4 pin Female
- Insulation PVC
- Nominal Resistance 100 Ω
- Number of Wires 4
- Process Connection Type Tri-Clamp
- Process Temperature, Max 200 °C
- Process Temperature, Min -50 °C
- Sheath Material 316L Stainless Steel
- Temperature Sensor Type RTD
Note: These Sensors Require an M12 Extension Cable to Connect the Sensor To Your Instrumentation. A Partial List Of Our M12 Extension Cables is Included in the Ordering Table Below.
Sanitary Temperature Sensor Specifications Include:
3A Approved 316L stainless steel wetted surfaces with surface finishes of 32 microinches or better.
Mounting flanges are 16AMP style conforming to ASME-BPE-2007 for proper fit with CIP systems. Probe designs include a 1/4' diameter standard duty and a stepped 3/16 to 3/8' heavy duty design. Standard probe lengths of 3, 4, 5 or 6' available from stock, other lengths available as special orders.
Sensor is a 4-wire, 100 ohm, Class A, Platinum Pt100 RTD meeting the requirements of IEC 60751.
Connection is a 4-pin M12 plug style connector.
These sensors can be used with 2-wire, 3-wire or 4-wire systems see information below.
Insulation resistance: 100 megohms minimum at 100 VDC.
Thermal response time of less than 2.5 seconds in water flowing at 3 ft/sec (63% response).
The 3-A Approved OMEGA™ PRS-S-M12 and PRS-H-M12 Series RTD Sensors are designed for use in Sanitary or Hygienic Clean-in-Place applications in the Food, Dairy, Beverage and BioPharmaceutical industries. These temperature sensors are manufactured with 316L stainless steel housings that meet the dimensional and finish requirements of 3-A Standard 74-05 and ASME BPE-2007, and are welded and processed to provide a clean, smooth, 32 microinch or better surface finish in the wetted areas for Clean-in-Place processes.
The probe stems are manufactured in two configurations; with a standard ¼' diameter probe for standard duty service, and a stepped 3/8' to 3/16' diameter probe design for good response times in heavy duty applications.
In addition to the standard 1½-16AMP process connection, these can be provided in the following sizes and styles:
If you need a process connection that is not listed above, please contact our sales department for availability.
A 4-Pin M12 Connector provides a quick and convenient connection point for process wiring. Omega offers a full line of M12 extension and patch cables in a variety of cable materials, lengths and connector configurations.
These sanitary RTD sensors are supplied standard as 4-wire assemblies with 4-pin connectors.
When used in 3-wire applications, use pins A, B and C as shown in the wiring detail below.
When used in 2-wire systems, connect one wire to pins A or B and the second wire to pins C or D as shown below.
This M12 connector style sensor is also available with a Thermistor sensing element in order to accommodate a wide variety of input requirements.
Sanitary Temperature Sensor Specifications Include:
The probe stems are manufactured in two configurations; with a standard ¼' diameter probe for standard duty service, and a stepped 3/8' to 3/16' diameter probe design for good response times in heavy duty applications.
In addition to the standard 1½-16AMP process connection, these can be provided in the following sizes and styles:
Process Connection | Model Number Code |
---|---|
3/4'-16AMP | -B1- |
1' and 1½'-16AMP | -D1- |
2'-16AMP | -E1- |
2½'-16AMP | -F1- |
3'-16AMP | -G1- |
4'-16AMP | -H1- |
If you need a process connection that is not listed above, please contact our sales department for availability.
A 4-Pin M12 Connector provides a quick and convenient connection point for process wiring. Omega offers a full line of M12 extension and patch cables in a variety of cable materials, lengths and connector configurations.
These sanitary RTD sensors are supplied standard as 4-wire assemblies with 4-pin connectors.
When used in 3-wire applications, use pins A, B and C as shown in the wiring detail below.
When used in 2-wire systems, connect one wire to pins A or B and the second wire to pins C or D as shown below.
Wiring Diagram |
This M12 connector style sensor is also available with a Thermistor sensing element in order to accommodate a wide variety of input requirements.
PDFs & Manuals
Accessories
Show Ratings & Reviews
Rated 5 out of
5
by
bryan11111 from
Only comment: Perfect!
Great products, the quality is spot on and as advertise. Shipping and service was perfect.
Date published: 2016-03-07
Rated 5 out of
5
by
brewengineer from
Very nice polished finish.
I purchased this RTD to monitor the temperature of a keg washing system at a small craft brewery. It fit perfectly and works great!
Date published: 2018-11-04
Is this sensor UL certified? I haven't been able to find any documentation relating to that. Thank you
Thanks for your inquiry, RTD's are not UL rated. Therefore this probe is not UL certified.
Date published: 2020-07-16