Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

We noticed you are from . Visit your local site for regional offers and live support.

DPU91-Series

Multi-Parameter Input Transmitter

Models In Stock
  • Large Auto-Sensing Backlit Display
  • “Dial-Style” Digital Bar Graph
  • Intuitive and “User-Friendly” Interface
  • Optional Field Upgradable Relays
DPU91-Series
From $ 489.60
Models In Stock
Multi-Parameter Input Transmitter DPU91-Series DPU91-Series
loading all models
Product Overview
  • Accuracy ± 0.5 %
  • Accuracy Detail ± 0.5% or reading maximum error @ 25°C (77ºF)
  • Additional Features 1 Field Mount, Sensors
  • Altitude,Max 4000 m
  • Conductivity Measurement 0.0000 to 99999 μS
  • Control Characteristics Dry-Contact Relays: 2 Open Collector: 1 Type: SPDT N/A Form C: N/A Maximum Current Rating: 5 A resistive 50 mA DC Maximum Voltage Rating: 30 Vdc or 250 Vac Hysteresis Adjustable: Absolute in engineering units (EUs) Latch Reset: In test screen only Delay: 9999.9 seconds (maximum) Test Mode: Set on/off Cycle Time: 99999 seconds (maximum) Maximum Pulse Rate: 400 pulses/minute Proportional Pulse: 400 pulses/minute Volumetric Pulse Width: 0.1 to 3200 s Pulse Width Modulation: 0.1 to 320 s
  • Display Measuring Units kΩ, MΩ, ms, ppb, ppm, μS
  • Display Note LCD Contrast: 5 settings
  • Display Type Backlit LCD
  • Display Type Note Backlit, 7 and 14-segment LCD
  • Electrical Connection Screw Terminal
  • Electrical Output 4 to 20 mA
  • Enclosure Material PBT
  • Enclosure Ratings IP65, NEMA Type 4X
  • Form factor 1/4 DIN
  • Frequency 0.5 to 1500 Hz
  • Input Note Digital Serial: ACSII, TTL level, 9600 bps Frequency Input: Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency Span: 0.5 Hz to 1500 Hz @ TTL level input
  • Input Type Pulse, S3L
  • Input Type Note Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850
  • Keypad 4 buttons, injection-molded silicone rubber seal
  • LED Indicators “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator
  • Measurement Type Flow, pH, ORP, conductivity, salinity, pressure, temperature, batch
  • Mounting Specified to Omega field mount junction boxes
  • Number of Channels 1
  • ORP Measurement Range -1999 to 1999.9 mV
  • Output Detail 4 to 20 mA (10.8 to 35.2 Vdc, 30 mA maximum)
  • Over-Voltage Protection 48 V transient protection device current limiting for circuit protection and reverse-voltage protection
  • PH Measurement Range 0 to 15 pH
  • Relative Humidity 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount
  • Repeatability ±0.2% of reading
  • Resolution 1 μS
  • Sensor Voltage 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected
  • Storage Temperature, Max 70 °C
  • Storage Temperature, Min -15 °C
  • Supply Power Note DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc
  • Supply Voltage 10.8 to 35.2 Vdc
  • Update Rate 1 sec
  • Weight 0.63 kg
  • Wire Gauge 14 AWG

The DPU91 transmitter provides a single channel interface for many different parameters including flow, pH/ORP, conductivity/resistivity, salinity and temperature. The DPU91-BC transmitter has the added capability of supporting the batch module for batching control. The extra-large (3.90 x 3.90') autosensing backlit display can be viewed at 4 to 5 times the distance over traditional transmitters. The highly illuminated display and large characters reduce the risk of misreading or misinterpreting the displayed values. The display shows separate lines for units, main and secondary measurements as well as a “dial-style” digital bar graph. The DPU91 is offered in both panel or field-mount versions. Both configurations can run on 12 to 32 Vdc power (24 Vdc nominal)and have 4 to 20 mA outputs. Designed for complete flexibility, plug-in modules allow the unit to easily adapt to meet changing customer needs. Optional modules include relay, direct conductivity/ resistivity, batch and a PC communications configuration tool. The unit can be used with default values for quick and easy programming or can be customized with labeling, adjustable minimum and maximum dial settings, and unit and decimal measurement choices.

DPU91 Series with Mating Flow Sensors
  DPU91 or DPU91-BC DPU91P or DPU91P-BC
FP-5100, FP-5200, FP-5300, FPB100, FMG3000 FD90UM and *sensor installation fitting, DPU90-AK(optional) *Sensor Installation fitting
Integral Mount
FP-5600, FP-8500, FP-8500A
FD90lUM and *sensor installation fitting, DPU90-AK(optional) Panel mount displays cannot be mounted integrally to the sensor
FP-5061, FP-5070, FP-2540, FMG-550 FP90UM, DPU90-AK(optional)

 

DPU91 Series with Mating pH/ORP Sensors Sensors
  DPU91  DPU91P
Submersible Mounted
PHE-2724, ORE-2725, PHE-2726
FD90UM, PHEH-275G DPU90-AK (optional) PHEH-275G
In-Line Mounted
PHE-2724, ORE-2725, PHE-2726
PHEH-275Y, *Sensor Installation fitting, DPU90-AK(optional) Panel Mount Displays cannot be mounted integrally to the sensor

 

DPU91 Series with Mating Conductivity/Resistivity/Sallnity Sensors
  DPU91 DPU91P
CDCE-90
Series Sensor*
FD90UM, DPU90-AK and DPU90-C DPU90-C


Specifications
General
Input Channels: 1
Input Types: Digital serial ASCII, TTL level, 9600 bps
Frequency Range: 0.5 to 1500 Hz
Accuracy: 0.5% of reading (display)
Measurement Types: Flow, pH/ORP, conductivity/resistivity, salinity, pressure, temperature or batch
Enclosure and Display
Case Material: PBT
Window: Shatter-resistant glass
Keypad: 4 buttons, injection-molded silicone rubber seal
Display: Backlit, 7 and 14-segment
Update Rate: 1 second
LCD Contrast: 5 settings
Indicators: “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator
Enclosure: ¼ DIN, NEMA 4X/IP65
Mounting Panel: ¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket (included)
Field Mounts: Specified to OMEGA™ field mount junction boxes
Weight: 0.63 kg (1.63 lb) 
Flow Rate: -9999 to 99999 units per second, minute, hour or day
Totalizer: 0.00 to 99999999 units (program lockout or resettable)
Temperature: -99 to 350°C (-146 to 662°F)
Volume: 0 to 99999 cm³, m³, in³, ft³, gal, L, lb, kg, %
Environmental
Ambient Operating Temperature:
    Backlit LCD: -10 to 70°C (14 to 158°F)
    Storage Temperature: -15 to 70°C (5 to 158°F)
Relative Humidity: 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount
Maximum Altitude: 4000 m (13,123')
Electrical Requirements
Power to Sensors:
    Voltage: 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected
    Terminal Blocks: Pluggable screw type 14 AWG maximum wire gauge
Input Power
DC: 10.8 to 35.2 Vdc, regulated
Current Output:
4 to 20 mA (10.8 to 35.2 VDC, 30 mA max)
DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc
DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc
Open Collector: 1
Overvoltage Protection: 48 V transient protection device current limiting for circuit protection and reverse-voltage protection
Relay Specifications (DPU90-R optional)
Type: SPDT, Form C
Maximum Current Rating: 5 A resistive 50 mA DC
Maximum Voltage Rating: 30 Vdc or 250 Vac
Hysteresis Adjustable: Absolute in engineering units (EUs)
Latch Reset: In test screen only
Delay: 9999.9 seconds (maximum)
Test Mode: Set on/off
Cycle Time: 99999 seconds (maximum)
Maximum Pulse Rate: 400 pulses/minute
Proportional Pulse: 400 pulses/minute
Volumetric Pulse Width: 0.1 to 3200 s
Pulse Width Modulation: 0.1 to 320 s
Input Types
Digital or AC Frequency: pH/ORP input via the digital output pH/ORP sensor electronics
Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850
Input Specifications
Digital Serial: ACSII, TTL level, 9600 bps
Frequency Input:
    Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency
    Span: 0.5 Hz to 1500 Hz @ TTL level input
Accuracy: ± 0.5% or reading maximum error @ 25°C (77°F)
Repeatability: ±0.2% of reading

Accessories

PC configuration took, includes so ftware
$334.12
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 24ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 59ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en
Save Configuration