Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

IF-002-Interface

Omega Link Smart Probe to Modbus RTU RS-485 serial Interface

Models In Stock
  • Modbus to Smart Probe Interface
  • Provides RS485 serial interface supporting Modbus RTU and command line interpreter
  • Configurable with Serial Terminal or SYNC configuration software
IF-002-Interface
From $ 146.46
Models In Stock
Omega Link Smart Probe to Modbus RTU RS-485 serial Interface IF-002-Interface IF-002-Interface
loading all models
Product Overview
  • Approvals CE
  • Baud Rate 9600 to 115200
  • Data Format 7 data bits: even parity: 1 stop bit, 7 data bits: even parity: 2 stop bit, 7 data bits: mark parity: 1 stop bit, 7 data bits: mark parity: 2 stop bit, 7 data bits: no parity: 1 stop bit, 7 data bits: no parity: 2 stop bit, 7 data bits: odd parity: 1 stop bit, 7 data bits: odd parity: 2 stop bit, 8 data bits: even parity: 1 stop bit, 8 data bits: even parity: 2 stop bit, 8 data bits: mark parity: 1 stop bit, 8 data bits: mark parity: 2 stop bit, 8 data bits:no parity:1 stop bit, 8 data bits: no parity: 2 stop bits, 8 data bits: odd parity: 1 stop bit, 8 data bits: odd parity: 2 stop bit
  • Electrical Connection M12 5-pin B code connector
  • Electrical Output 100 mA max @ 3.0 ±5%
  • Enclosure Ratings IP67
  • Length 3.8 in
  • Number of Channels 1
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Parity Even, Odd, Mark, None
  • Software Compatibility Windows 10 OS or higher. Compatible with OEG, SYNC configuration software,Omega Link Cloud, and Modbus Networks
  • Supply Power Note Voltage: 5VDC - 36 VDC
  • Supply Power Type DC
  • Supply Voltage 5 to 36 Vdc
  • Width 0.87 in

Omega Link to Modbus Integration

The IF-002 provides seamless integration of your Omega Link Smart Probe to your Modbus network. The IF-002 utilizes a standard M12 5-pin B code connector for RS485 serial transmission and an M12 8-pin connector for Omega Link Smart Probes.

The M12 8-pin connector provides power for external Omega Link Smart Probes with an integrated power monitor to protect against short circuits.

Intuitive Configuration

An integrated command line interface allows for quick serial setup of your IF-002 and smart probe, register configuration, and monitoring using standard terminal emulators. Intuitive configuration is also available through SYNC configuration software.

Compatibility

The IF-002 is fully compatible with SYNC configuration software, the Omega Link Ecosystem of devices, Omega Enterprise Gateway, and Omega Link Cloud.


Specifications

RS485 Serial Port
Baudrate: 9600, 19200, 34800,115200
Parity: : Even, Odd, Mark, None
Data Bits: 7, 8
Stop Bits: 1, 2
Protocol: Modbus RTU, Command Line Interpreter
INPUT POWER
Voltage: 5VDC - 36 VDC
OUTPUT TO SMART PROBE
100 mA @ 3.0 V ±5%
ENVIRONMENTAL
Operating Temperature: -40 to 85℃ (-40 to 185℉)
Rating: IP67 when mated
MECHANICAL
Dimensions: 22.1 mm W x 96.7 mm L (0.87” x 3.80”) not including mounting tabs
GENERAL
Agency Approvals: CE, EMC 2014/30/EU, LVD 2014/35/EU
Compatibility: Compatible with OEG, SYNC configuration software, Omega Link Cloud, and Modbus Networks

M12 8-Pin Wiring

Pin Name Function
Pin 1 OUT 1 No Connection
Pin 2 INTR Interrupt Signal
Pin 3 SCL SCL Signal
Pin 4 SDA SDA Signal
Pin 5 Shield Shield Ground
Pin 6 OUT 2 No Connection
Pin 7 GND Power Return
Pin 8 VCC Nominal 3.0 VDC to Smart Probe

M12 5-Pin Wiring

Pin Name Function
Pin 1 VDD 5-36 VDC
Pin 2 A’ RS485 Data +
Pin 3 GND Ground
Pin 4 B’ RS485 Data -
Pin 5 SHIELD Shield Ground

Modbus Smart Interface

Model Number Description
IF-002 SModbus RS485 Smart Interface

 

Accessories

An M12 5-pin B code screw terminal connector is required to connect your IF-002 to your modbus network.

Model Number Description
M12.5-B-S-F-FM M12 5-pin B code screw terminal
DM12CAB-8-1-RA 1m (3.3’) cable dual M12-8 connector, right angle terminator
DM12CAB-8-3-RA 3m (9.8’) cable dual M12-8 connector, right angle terminator
DM12CAB-8-5-RA 5m (16.4’) cable dual M12-8 connector, right angle terminator
DM12CAB-8-1 1m (3.3’) cable dual M12-8 straight connector
DM12CAB-8-3 3m (9.8’) cable dual M12-8 straight connector
DM12CAB-8-5 5m (16.4’) cable dual M12-8 straight connector

 

Omega Link Smart Probes

Compatible Omega Link Smart Probes are integrated with an advanced suite of IIoT Smart Core features. These features enable plug and play connectivity, alarms and notifications, data assurance, data logging, and storage.

Model Number Description
SP-001-0 Smart Probe IR, 6:1 field of view
SP-001-1 Smart Probe IR, 6:1 field of view, with discrete I/O
SP-002-0 Smart Probe IR, 10:1 field of view
SP-002-1 Smart Probe IR, 10:1 field of view with discrete I/O
SP-003-1 THB Smart Probe with I/O Tube Housing
SP-004-1 TH Smart Probe with I/O Tube Housing
SP-004-4 TH Smart Probe with I/O Bulkhead Housing
SP-005-1 Temperature and RTD Smart Probe with discrete I/O
SP-010-1 Load Cell Smart Probe with discrete I/O
SP-013-1 Digital Interface Smart Probe with discrete I/O
SP-014-1 Process Monitoring Smart Probe with discrete I/O
SP-016-1 Heat Flux Smart Probe with discrete I/O
Rated 5 out of 5 by from Perfect for modbus applications Easy to buy and connects with Modbus. Can also connect to EZE IO
Date published: 2023-02-09
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_IF-002, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Can this device be used on custom MODBUS RTU networks rather than LayerN? By directly interfacing with the data line on M12 5-pin RS-485 data lines? Thank you

Asked by: Vick
We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM”
Answered by: Application Engineer PV
Date published: 2021-11-15
  • y_2025, m_2, d_22, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_IF-002, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 31ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration