- Approvals CE
- Baud Rate 9600 to 115200
- Data Format 7 data bits: even parity: 1 stop bit, 7 data bits: even parity: 2 stop bit, 7 data bits: mark parity: 1 stop bit, 7 data bits: mark parity: 2 stop bit, 7 data bits: no parity: 1 stop bit, 7 data bits: no parity: 2 stop bit, 7 data bits: odd parity: 1 stop bit, 7 data bits: odd parity: 2 stop bit, 8 data bits: even parity: 1 stop bit, 8 data bits: even parity: 2 stop bit, 8 data bits: mark parity: 1 stop bit, 8 data bits: mark parity: 2 stop bit, 8 data bits:no parity:1 stop bit, 8 data bits: no parity: 2 stop bits, 8 data bits: odd parity: 1 stop bit, 8 data bits: odd parity: 2 stop bit
- Electrical Connection M12 5-pin B code connector
- Electrical Output 100 mA max @ 3.0 ±5%
- Enclosure Ratings IP67
- Length 3.8 in
- Number of Channels 1
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Parity Even, Odd, Mark, None
- Software Compatibility Windows 10 OS or higher. Compatible with OEG, SYNC configuration software,Omega Link Cloud, and Modbus Networks
- Supply Power Note Voltage: 5VDC - 36 VDC
- Supply Power Type DC
- Supply Voltage 5 to 36 Vdc
- Width 0.87 in
Omega Link to Modbus Integration
The IF-002 provides seamless integration of your Omega Link Smart Probe to your Modbus network. The IF-002 utilizes a standard M12 5-pin B code connector for RS485 serial transmission and an M12 8-pin connector for Omega Link Smart Probes.
The M12 8-pin connector provides power for external Omega Link Smart Probes with an integrated power monitor to protect against short circuits.
Intuitive Configuration
An integrated command line interface allows for quick serial setup of your IF-002 and smart probe, register configuration, and monitoring using standard terminal emulators. Intuitive configuration is also available through SYNC configuration software.
Compatibility
The IF-002 is fully compatible with SYNC configuration software, the Omega Link Ecosystem of devices, Omega Enterprise Gateway, and Omega Link Cloud.

Specifications
RS485 Serial Port
Baudrate: 9600, 19200, 34800,115200
Parity: : Even, Odd, Mark, None
Data Bits: 7, 8
Stop Bits: 1, 2
Protocol: Modbus RTU, Command Line Interpreter
INPUT POWER
Voltage: 5VDC - 36 VDC
OUTPUT TO SMART PROBE
100 mA @ 3.0 V ±5%
ENVIRONMENTAL
Operating Temperature: -40 to 85℃ (-40 to 185℉)
Rating: IP67 when mated
MECHANICAL
Dimensions: 22.1 mm W x 96.7 mm L (0.87†x 3.80â€) not including mounting tabs
GENERAL
Agency Approvals: CE, EMC 2014/30/EU, LVD 2014/35/EU
Compatibility: Compatible with OEG, SYNC configuration software, Omega Link Cloud, and Modbus Networks
M12 8-Pin Wiring

Pin | Name | Function |
---|---|---|
Pin 1 | OUT 1 | No Connection |
Pin 2 | INTR | Interrupt Signal |
Pin 3 | SCL | SCL Signal |
Pin 4 | SDA | SDA Signal |
Pin 5 | Shield | Shield Ground |
Pin 6 | OUT 2 | No Connection |
Pin 7 | GND | Power Return |
Pin 8 | VCC | Nominal 3.0 VDC to Smart Probe |
M12 5-Pin Wiring

Pin | Name | Function |
---|---|---|
Pin 1 | VDD | 5-36 VDC |
Pin 2 | A’ | RS485 Data + |
Pin 3 | GND | Ground |
Pin 4 | B’ | RS485 Data - |
Pin 5 | SHIELD | Shield Ground |
Modbus Smart Interface
Model Number | Description |
---|---|
IF-002 | SModbus RS485 Smart Interface |
Accessories
An M12 5-pin B code screw terminal connector is required to connect your IF-002 to your modbus network.
Model Number | Description |
---|---|
M12.5-B-S-F-FM | M12 5-pin B code screw terminal |
DM12CAB-8-1-RA | 1m (3.3’) cable dual M12-8 connector, right angle terminator |
DM12CAB-8-3-RA | 3m (9.8’) cable dual M12-8 connector, right angle terminator |
DM12CAB-8-5-RA | 5m (16.4’) cable dual M12-8 connector, right angle terminator |
DM12CAB-8-1 | 1m (3.3’) cable dual M12-8 straight connector |
DM12CAB-8-3 | 3m (9.8’) cable dual M12-8 straight connector |
DM12CAB-8-5 | 5m (16.4’) cable dual M12-8 straight connector |
Omega Link Smart Probes
Compatible Omega Link Smart Probes are integrated with an advanced suite of IIoT Smart Core features. These features enable plug and play connectivity, alarms and notifications, data assurance, data logging, and storage.
Model Number | Description |
---|---|
SP-001-0 | Smart Probe IR, 6:1 field of view |
SP-001-1 | Smart Probe IR, 6:1 field of view, with discrete I/O |
SP-002-0 | Smart Probe IR, 10:1 field of view |
SP-002-1 | Smart Probe IR, 10:1 field of view with discrete I/O |
SP-003-1 | THB Smart Probe with I/O Tube Housing |
SP-004-1 | TH Smart Probe with I/O Tube Housing |
SP-004-4 | TH Smart Probe with I/O Bulkhead Housing |
SP-005-1 | Temperature and RTD Smart Probe with discrete I/O |
SP-010-1 | Load Cell Smart Probe with discrete I/O |
SP-013-1 | Digital Interface Smart Probe with discrete I/O |
SP-014-1 | Process Monitoring Smart Probe with discrete I/O |
SP-016-1 | Heat Flux Smart Probe with discrete I/O |
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 5 out of
5
by
Sohrab G from
Perfect for modbus applications
Easy to buy and connects with Modbus. Can also connect to EZE IO
Date published: 2023-02-09
Can this device be used on custom MODBUS RTU networks rather than LayerN? By directly interfacing with the data line on M12 5-pin RS-485 data lines? Thank you
We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM”
Date published: 2021-11-15