1-800-663-4209 | Vos commentaires sont importants, répondez à un sondage rapide commentaires sur le site web

CN38S-Series
Temperature Autotune Controller with Sensitive Touch Keypad
Modèles en stock
CN38S-Series
Depuis
$
205.74
Modèles en stock

L'aperçu du produit
Afficher les notes et les avis
Rated 5 out of
5
by
biff from
It's the Bomb!
This little unit works sweet. If you need a 12 volt controller, this is the bomb! I am using this as a fan control for my rocket stove. I needed a higher sensor range than I could get with the 15 dollar Inkbird controller. I haven't had much experience with controllers other than an Inkbird 120v that I used for an old coffee vending machine @ 95c max, and Omega CN7500 120v that I used for a kiln. It seems easy enough to operate. NOTE, the sensor must be isolated. I blew up the first two (my fault) by not isolating the probe from the metal frame of the rocket stove.
Date published: 2017-10-03
Rated 3 out of
5
by
Nickname already used from
Misleading!
The specification sheet shows the unit supporting both Pt100 and Pt1000 sensors, so I ordered the RTD unit only to discover that it supports ONLY Pt100. For Pt1000 support you need to buy the thermistor unit!! The product selection tool and the specifications page make no mention of this - this detail is buried in the manual.
Date published: 2022-05-02
Rated 3 out of
5
by
Lonuf from
Works as needed. Should have more features.
Disappointed in the missing options. Manual shows options that are not available on device. The option to enable decimal point is not installed. Does not make sense as it is a basic function. The menu skips over that option. They do not tell you this and do not give you the model that allows this function.
Date published: 2021-12-22
Hello, can I use it with an external temperature sensor ? I always need to know the temperature inside my product to adapt the voltage and get as close as possible to the desired temperature. Thank's
The CN38S series does accept Thermocouples RTD's and Thermistors to display temperature.
Date published: 2023-07-10
I want to use this with 10k NTC thermistors, but I need to know which temperature curve it is designed for. For example: 3969K
Thank you for your inquiry. You may use the NTC 10k curve. This would be Thermistors 44006 or 44031 located on our "Thermistor Resistance Temperature" table located in the RTD & Thermistor Reference Data category at this technical reference: https://www.omega.co.uk/temperature/Z/zsection.asp
Date published: 2021-12-23
Cn 38s Does this unit have a built in dc rectifier?
Hi Jonny,
Thank you for the inquiry. Yes, the DC rectifier is built in.
Best regards,
OMEGA
Date published: 2020-05-19
I'm trying to use the CN38S-TC-DC1-DC2 with a refrigerator and set the "PCT" "compressor protection time" to 5 minutes. this wait-time is however ignored and it keeps switching on and off within a few seconds. does "PCT" only work in On/OFF mode?
Thank you for contacting Omega. The PCT feature is only available if at least one output is programmed as cooling. With the controller being connected to a refrigerator, that would be a cooling application. Our Tech Support engineer has emailed you to confirm that you do have the controller programmed for cooling and help resolve this for you.
Date published: 2019-06-20
Hello! Does this PID controller work with a 2252 NTC thermistor?
Thank you for your inquiry. No, this PID controller does not work with a 2252 ohm NTC thermistor.
Date published: 2022-09-28
RoHS 2015/863 - Voir le certificat
Approuvé CE