Welcome to our new website, found an issue or bug? Please report it here
HH520
Four Channel Handheld Data Logger Thermometer

Choose a Variant
Display Type
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $438.72 |
5-9 | $416.78 |
10-24 | $408.01 |
25-49 | $390.46 |
50-99 | $381.69 |
100+ | $372.91 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Additional Features 1 | Data Logging Capability |
Battery life | 100 hr |
Data Interface | USB |
Display Type | Backlit LCD |
Height | 187 mm |
Input Protection Voltage | 30 Vrms |
Length | 29 mm |
Measurement Type | Thermocouple |
Number of Channels | 4 |
Operating Temperature Note | 0 to 50°C (32 to 122°F);10 to 90% RH non-condensing |
Sampling Rate | 2.5 Hz (2.5 updates/second) |
Software Compatibility | Windows® XP/Vista/7/8/10 |
Storage Temperature Note | -20 to 60°C(-4 to 140 °F); 10 to 75% RH |
Storage Temperature, Max | 60 °C |
Storage Temperature, Min | -20 °C |
Supply Voltage | 6 Vdc |
Temperature Accuracy | ± 0.1% |
Temperature Accuracy Note | (Does Not Include Thermocouple Sensor Error):± (0.1% rdg + 0.7°C)/± (0.1% rdg + 1.4°F) between 18 to 28°C (64 to 82°F); ± (0.4% rdg + 0.7°C)/± (0.4%rdg + 1.4°F) below -100°C (-148°F) |
Temperature Coefficient | 0.01% of reading + 0.05°C per °C(<18 or >28°C) |
Temperature Resolution | 0.1 °C |
Temperature Resolution Note | 0.1°C <600°C (0.1°F <1000°F); 1.0°C ≥ 600°C (1.0°F ≥ 1000°F) |
Weight | 290 g |
Weight Note | 290 g (10.2 oz) |
Width | 75 mm |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 4 out of
5
by
omnifn from
Value and practical
Value and practical. In stock and prompt delivery. Software may need one more option on grid layout: such as smaller checker board squares on the background to identify data point location. A longer USB cable would be better. On Windows XP, each time the logger is manually powered off and on again and then the hardware driver is automatically installed while USB was plugged in, but need to uninstall and install it again one more time to avoid installation issue. This would need to state in the manual.
Date published: 2018-03-10
Rated 5 out of
5
by
Gabe Oakes from
Data Logger
Exactly what I was looking for. Had four channels which I needed.
Date published: 2023-08-14