HTWC-Series
Silicone Rubber Heater Tape 425 °F Max and 0.72 kW Max Power
Models In Stock
- NOT FOR EXPORT TO CANADA
- Reliable
- Integral Percentage Controller
- Silicone Rubber Encapsulated Heating Tape
HTWC-Series
From
$
162.74
Models In Stock

Product Overview
- Electrical Connection Note Rugged and dependable percentage controller. Includes power cord and 2 prong plug
- Exposure Temperature, Max 232 °C
- Heater Diameter 0 in
- Heater Width 1 in
- Insulation Silicone Rubber
- Insulation Note Fine gage stranded resistance wires insulated with fiberglass yarn and completely enclosed in a silicone rubber extrusion
- Lead Wire Exit Direction Same
- Material Construction Option N/A
- Power Density, Max 72 W/ft²
- Power Density Note 72 W/ft² (Linear)
- Thermostat Type Built-In
- Wire Length 72 in
The HTWC Series tape consists of a flexible heating strip 1' wide and of varying lengths with a permanently incorporated temperature controller. Standard tapes are available for either 120 or 240 volt operation and develop 72 watts per lineal foot. These tapes are completely safe when operated according to directions, and with reasonable care, will give long service.
This economical semi-automatically controlled heating tape has been developed by OMEGALUXâ„¢ for use in small scale heating applications.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings.
This economical semi-automatically controlled heating tape has been developed by OMEGALUXâ„¢ for use in small scale heating applications.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings.
Watts | Volts | Size | Model No. |
144 | 120 | 1' x 2' | HTWC101-002 |
288 | 120 | 1' x 4' | HTWC101-004 |
432 | 120 | 1' x 6' | HTWC101-006 |
576 | 120 | 1' x 8' | HTWC101-008 |
720 | 120 | 1' x 10' | HTWC101-010 |
144 | 240 | 1' x 2' | HTWC102-002 |
288 | 240 | 1' x 4' | HTWC102-004 |
432 | 240 | 1' x 6' | HTWC102-006 |
576 | 240 | 1' x 8' | HTWC102-008 |
720 | 240 | 1' x 10' | HTWC102-010 |
PDFs & Manuals
Show Ratings & Reviews
Rated 1 out of
5
by
Timm from
Heat Tape Experience
The HTWC that I have doesn't regulate the wattage by percentage. My unit doesn't activate any wattage until I pass the 85-90% mark at which point it gives full power to the tape. In order to regulate the heat, I then have to turn the dial back to about the 50% mark before the power cuts out on the tape. The only way to regulate the tape temperature is to tediously sit and toggle the unit on and off frequently. If you are looking for a regulated heat tape I would not recommend this product.
Date published: 2017-08-25
Rated 5 out of
5
by
Djdiddles from
good product!
does what is described. it heats the piping we have to keep lines warm
Date published: 2022-11-03
Rated 2 out of
5
by
Vijay Deva from
Heater
The heater burned as I was testing it. It did not come with any safety shutoff that could have prevented overheating
Date published: 2022-03-02
Rated 5 out of
5
by
Carol10 from
Heater tape
solved my problem without involving a water bath to keep a liquid from freezing
Date published: 2019-03-01
Rated 5 out of
5
by
GEEMDCO from
Excelent Product
100% Recommended. Excellent web page and products.
Date published: 2018-09-02
Rated 2 out of
5
by
trav from
Arrived Broken
This showed up non-functioning after purchasing 2 day shipping. I could hear something rattling around in the controller. Turns out there was a set screw that had fallen out of one of the controller components, and I was able to repair it myself since I needed it rapidly. Works well now.
Date published: 2018-03-15
How does the percentage controller work? If I set the controller to 50% for a 244W heater tape, does it consistently provide 122W of power to the heater tape?
This Time Percentage controller varies the proportion (length) of time the heater is in the "on" or "off" heating mode. The heating application will determine the actual percentage set-point required. The controller does not use a temperature sensor and therefore satisfactory operation requires occasional supervision under changing load conditions.
Date published: 2023-11-17
What is the minimum temperature this element can be set to? I'm attempting 45 C and was wondering if that would be possible.
There is not really a low temperature that can be set just the lowest time the Heater will be on. It seems if it is set to the low end of the proportional dial 45C should be achievable dependent on variables like thermal load and ambient temperature conditions.
Date published: 2023-12-04