Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

LCMCD

Metric, IP67 Environmentally Protected S-Beam Load Cells

Models In Stock
  • Environmentally Protected to IP67
  • All Stainless Steel for Industrial Environments
  • 5 Point NIST Traceable Calibration with 59 kOhm Shunt Cal Data Provided
  • Tension Calibration Standard
LCMCD
From $ 599.90
Models In Stock
Metric, IP67 Environmentally Protected S-Beam Load Cells LCMCD LCMCD
loading all models
Product Overview
  • Bridge Resistance 350 Ω
  • Cable Length 20 ft
  • Calibration Option 5 POINT NIST
  • Creep in 20 min ± 0.03%
  • Electrical Connection Cable
  • Electrical Output 3 mV/V
  • Enclosure Ratings IP67
  • Force Type Compression, Tension
  • Hysteresis 0.0002
  • Interchangeability 0.0025
  • Load Cell Type S-beam
  • Materials 17-4 PH Stainless Steel
  • Operating Temperature, Max 66 °C
  • Operating Temperature, Min -18 °C
  • Overload, Max 300% FS
  • Process Temperature, Max 66 °C
  • Process Temperature, Min -18 °C
  • Repeatability 0.0001
  • Safe Overload 150% FS
  • Supply Power Note 10 Vdc, 15 Vdc maximum
  • Supply Voltage 10 Vdc
  • Thermal Span Effect 0.0015% rdg/°C
  • Thermal Zero Effect 0.0027% FS/°C
  • Wire Gauge 22 AWG
  • Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
  • Zero/Balance Error 0.01

The LCMCD is also available in standard configurations, with 0-25 to 0-20,000 lb ranges and standard threads. Please see the LCCD for complete details, or contact our Pressure department for more information.

SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc maximum)
Output: 3.0 mV/V ± 0.25%
Linearity: 0.03% FS
Hysteresis: 0.02% FS
Repeatability: 0.01% FS
Zero Balance: 1% FS
Creep in 20 min: 0.03% FS
Operating Temperature: -18 to 66°C (0 to 150°F)
Compensated Temperature: -18 to 66°C (0 to 150°F)
Thermal Effects:
Zero: 0.0027% FS/°C
Span: 0.0015% rdg/°C
Maximum Load: Safe, 150%; ultimate, 300%
Bridge Resistance: 350 ? nominal
Construction: 17-4 PH stainless steel
Cable: 6 m (20') 4-conductor shielded 22-gage wire
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 35ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration