Models In Stock
  • IO-Link capable switching output and a 4-20mA analog output
  • Scalable temperature range from -50 to 200°C (-58 to 392°F)
  • Designed for sanitary applications
  • Wetted surfaces are 316L Stainless Steel with a surface finish of 32µ" or better
PRTXS
From $ 303.17
Models In Stock
Sanitary RTD Probe with IO-Link, 4 to 20 mA, and Switched Output PRTXS PRTXS
loading all models
Product Overview
  • Accuracy Class A
  • Accuracy Note Class A per IEC60751 Full Measuring Range ± 0.55 °C (0.99 °F) Scaled Measuring Range ± [0.215 °C (0.39 °F) + 0.134 % x (Measuring Span)]
  • Certifications 3-A, CE, EHEDG, UKCA
  • Digital Output IO-Link Communication
  • Digital Output Note IO-Link Communication / PNP Switch (200 mA) / Analog 4-20 mA
  • Electrical Connection M12 4 pin Female
  • Electrical Output 4 to 20 mA
  • Enclosure Ratings IP67, IP68, IP69K
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Operating Voltage, Max 30 VDC
  • Operating Voltage, Min 15 VDC
  • Operating Voltage Note 15 to 30 VDC (IO-Link/Switch); 10 to 30 VDC (Analog)
  • Probe Diameter 0.25 in
  • Process Connection Type Tri-Clamp
  • Process Temperature, Max 200 °C
  • Process Temperature, Min -50 °C
  • Response Time 4 sec
  • Sheath Material 316L Stainless Steel
  • Temperature Sensor Type RTD

The Omega PRTXS series of temperature transmitters are IO-Link capable for reliable, bi-directional, point to point communication for process data and sensor configuration; Also equipped with a scalable 4-20mA analog output and a switched output that can handle current draws up to 200mA. These sensors utilize a PT100 Class A RTD element to provide an accuracy of +/- 0.55°C throughout the entire measuring range of -50...+200°C (-58...+392°F). Made with a fully welded 316L Stainless Steel housing, the sensor has excellent corrosion resistance and is IP69K rated. Available in standard lengths from 2" to 6", with a probe diameter of 1/4", and sanitary flanges in sizes of 1.5", 2.0", 2.5". All wetted surfaces are 316L Stainless Steel with a surface finish of 32 microinches or better, suitable for use in Sanitary, Hygienic, and Clean-In-Place Food, Dairy, Beverage and Biopharmaceutical Applications.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Is this considered as 3 wire or 4 wire temperature probe??

Asked by: superkk
Thank you for your inquiry. It is neither because this probe has either IO-Link or a 4-20mA output.
Answered by: NorwalkAE_SP
Date published: 2024-05-20
  • y_2025, m_2, d_21, h_8CST