Product Overview
  • Accuracy ± 0.5 %
  • Accuracy Class > 0.25%
  • Accuracy Note ± 0.5% TP; ± 0.40% BFSL includes non-linearity, hysteresis and non-repeatability, zero offset and span setting errors (add 0.05% for ranges above 5000 psi)
  • Additional Features 1 None
  • Compensated Temperature, Max 85 °C
  • Compensated Temperature, Min -20 °C
  • Electrical Output 4 to 20 mA
  • Electrical Output Note 4 to 20 mA(2 wire)
  • Enclosure Material 304 Stainless Steel
  • Enclosure Ratings IP65, NEMA Type 7, NEMA Type 9
  • Fits Cable Diameter 9 to 12 mm
  • Insulation Resistance 100 MΩ
  • Materials, Wetted 316 Stainless Steel
  • Operating Temperature, Max 125 °C
  • Operating Temperature, Min -40 °C
  • Position Effect ± 0.02% typical
  • Process Connection Note 1/2 NPT male conduit fitting and 4.6 m (15') cable with flying lead termination
  • Process Temperature, Max 125 °C
  • Process Temperature, Min -40 °C
  • Protection Reverse polarity and mis-wire protected
  • Relative Humidity 0 to 0.95
  • Response Time 2 ms
  • Stability ≤± 0.25%
  • Stability Note ≤± 0.25% span/year @ ref conditions (21°C/70°F)
  • Storage Temperature, Max 125 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note 12 to 32 Vdc Vmin=12V+(0.022Ax loop res)
  • Supply Voltage 12 to 32 Vdc
  • Thermal Effect on Span error, Max 2% span
  • Thermal Effect on Zero error, Max 2% span
  • Vibration 100 g peak, 11 ms; Vibration Random: 10 g RMS, 20 to 2000 Hz; Vibration Sweep : 50 to 2000 Hz, 5 g peak
  • Weight 254 g

The PX835 explosion proof / flame proof pressure transmitter is ideal for a broad spectrum of pressure sensing requirements, requiring hazardous location approvals for explosion proof, flame proof or intrinsically safe. The PX835 is designed with an all welded stainless steel case and manufactured to provide the user with accurate, reliable, and stable output data. This is accomplished through the use of state of the art sensor technology combined with digital calibration to provide extremely linear and precise performance over the entire specified pressure and temperature range.

SPECIFICATIONS
Output: 4 to 20 mAdc (2-wire)
Supply Voltage: 12 to 32 Vdc Vmin = 12 V + (0.022A x loop res)
Insulation Resistance (Circuit to Case): 100M Ω @ 30 Vdc
Circuit Protection: Reverse polarity and mis-wire protected
Accuracy: ± 0.5% TP; ± 0.40% BFSL includes non-linearity, hysteresis and non-repeatability, zero offset and span setting errors (add 0.05% for ranges above 5000 psi)
Stability: ≤± 0.25% span/year @ ref conditions (21°C/70°F)
Response Time: 2 ms
Storage/Process/Operating Temperature: -40 to 125°C (-40 to 257°F)
Compensated Temperature: -20 to 85°C (-4 to 185°F)
Temperature Effects (Over Comp Range): 2% span
Humidity Effects: No performance effects 0 to 95% RH, non-condensing
Vibration:
Shock: 100 g peak, 11 ms
Random: 10 g RMS, 20 to 2000 Hz
Sweep: 50 to 2000 Hz, 5 g peak
Position Effect: ± 0.02% typical
Electrical Termination: ½ NPT male conduit fitting and 4.6 m (15') cable with flying lead termination
Pressure Connection: ¼ NPT male
Environmental Rating: NEMA 7, 9 (IP65)
Hazardous Area Certifications:
Explosion Proof - cUL (USA/CNL):
Specify PX835; Class I, Div 1 & 2, Groups A, B, C, and D; Class II, Div 1 & 2, Groups E, F, and G
Flame Proof - ATEX: Specify PX835 II 2 G; Ex d IIC T4
Intrinsically Safe - FM/CSA: Class I, Div 1; Class I, Div 2, non-incendive
CE Compliance: EN 61326: 1997 + A1: 1998 Annex A, A2/2001 Heavy Industrial Immunity (Annex A table A.1); Light Industrial/Residential Emission (Table 4)
Wetted Parts: 316SS diaphragm and pressure port
Case: 304 SS
Cable Gland: Fits cable diameter 9 to 12 mm (0.35 to 0.47")
Weight: Approximately 254 g (8 oz)

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Do these have span and zero pods that can be adjusted?

Asked by: Tc41
no, we do not have adjustment pots on the PX835
Answered by: rkent
Date published: 2021-06-21

Where are the wiring diagrams and ancillary parts recommended and/or required for approved Intrinsicly Safe installation? The User Guide briefly references "See Omega drawing #825A027", but a search for this term brings up only the User Guide.

Asked by: CDunn
Thank you for your inquiry, this document can be obtained by contacting us at pressure@omega.com.
Answered by: rkent
Date published: 2022-11-02

Do you know what the Performance Level (a-e) of this sensor is?

Asked by: ScottB
Thank you for your inquiry, that information can be found in the manual under hazardous area certification.
Answered by: rkent
Date published: 2022-09-08

Do these carry a GOST or GOST R compliance certification (Russian Metrology)?

Asked by: SDoll
These do not carry that certification, all the certifications that are available with this device are noted in the data sheet link above.
Answered by: PressureENG
Date published: 2020-04-09
  • y_2025, m_2, d_22, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_US, sid_PX835-005GI, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 15ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration