Welcome to our new website, found an issue or bug? Please report it here

RSC-RSM-CABLE
Retractable Cable, 2 wire, Thermocouples, RTDs, Thermistors
Models In Stock
- J, K, T and E Thermocouple Calibrations and 3-Wire Copper for RTD\xe2\x80\x99s and Thermistors
- Expansion Ratio up to 500%\xe2\x80\x941 Foot of Cable Stretches to 5 Feet
- TPE Plastic Jacket for Indoor and Outdoor Use to 220\xc2\xb0F (104\xc2\xb0C)
- Retracted Coil Lengths of 1, 2, 3 and 4 Feet with 6' Straight Ends
RSC-RSM-CABLE
From
$
13.95
Models In Stock

Product Overview
- Additional Features 1 None
- Cable Type Insulated Coiled
- Insulation TPE
- Operating Temperature, Max 105 °C
- Operating Temperature, Min -30 °C
- Overbraiding Type None
- Tolerance Length ± 10%
- Wire Gauge 28 AWG
- Wire Type 7 x 36 Stranded
OMEGA™ Retractable Sensor Cable is color coded and spring coiled, for use with thermocouples, RTD’s and thermistors.
To achieve a superior jacket construction, OMEGA has employed the latest in jacketing material: TPE (thermoplastic elastomer), a unique family of thermoplastics which exhibits characteristics previously found only in rubber compounds. TPE is extremely tough and flexible, and has excellent abrasion resistance. Our special construction technique yields an expansion rate of up to 500%.
OMEGA’s retractable sensor cables are specifically recommended for use with electronic-type indicators, either panel, handheld or bench type models. The cables should not be used with self powered, unamplified analog meters, such as OMEGA™ Series 7000 pyrometers. Retractable sensor cables have hundreds of applications: oscillating machinery, handheld surface probes, or wherever retractable sensor cables are required.
Color Code of Cables
Typical Resistance of Cables
How To Order
1. Fill the 1st box (1) with desired ANSI Calibration. Use ANSI symbols “J”, “K”, “T”, “E” for thermocouple calibration; “RTD” for resistance temperature detector; or “TH” for thermistor.
2. Fill in 2nd box (2) with retracted coil length in cm (ft): 30 (1), 60 (2), 90 (3) or 120 (4).
3. Fill in 3rd box (3) with termination style number (one end).
4. Fill in 4th box (4) with termination style number (other end).
* M = Miniature Retractable Cable
Indicate associated meter or pin out desired for connector
To achieve a superior jacket construction, OMEGA has employed the latest in jacketing material: TPE (thermoplastic elastomer), a unique family of thermoplastics which exhibits characteristics previously found only in rubber compounds. TPE is extremely tough and flexible, and has excellent abrasion resistance. Our special construction technique yields an expansion rate of up to 500%.
OMEGA’s retractable sensor cables are specifically recommended for use with electronic-type indicators, either panel, handheld or bench type models. The cables should not be used with self powered, unamplified analog meters, such as OMEGA™ Series 7000 pyrometers. Retractable sensor cables have hundreds of applications: oscillating machinery, handheld surface probes, or wherever retractable sensor cables are required.
Color Code of Cables
ANSI Code | Calibration | Jacket | +Wire | –Wire |
J | Iron/Constantan | Black | White | Red |
K | CHROMEGA™/ALOMEGA™ | Yellow | Yellow | Red |
T | Copper/Constantan | Blue | Blue | Red |
E | CHROMEGA™/Constantan | Purple | Purple | Red |
RTD/TH | Copper (3-Wire) | White | 2 Black | Red |
Typical Resistance of Cables
Ohms Per Running Foot of Cable 30 cm (1 ft) Coiled (150 cm [5 ft] Extended) | Ohms Per Foot of Wire Three Wires Per Cable) | ||||
J | K | T | E | RTD and Thermistor | |
16.3 | 27.5 | 14 | 33.1 | 0.57 |
Model No. | Input Type | O.D. mm (in) |
RSC-(1)-(2)-(3)-(4) | T/C | 4.2 mm (0.165') |
RSC-RTD-(2)-(3)-(4) | RTD | 4.4 mm (0.175') |
RSC-TH-(2)-(3)-(4) | TH | 4.24 mm (0.175') |
RSCM*-(1)-(2)-(3)-(4) | T/C | 3.4 mm (0.135') |
1. Fill the 1st box (1) with desired ANSI Calibration. Use ANSI symbols “J”, “K”, “T”, “E” for thermocouple calibration; “RTD” for resistance temperature detector; or “TH” for thermistor.
2. Fill in 2nd box (2) with retracted coil length in cm (ft): 30 (1), 60 (2), 90 (3) or 120 (4).
3. Fill in 3rd box (3) with termination style number (one end).
4. Fill in 4th box (4) with termination style number (other end).
* M = Miniature Retractable Cable
Indicate associated meter or pin out desired for connector
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
K2THAG from
Quality Product
compact, easy to handle and use, great quality. 10/10 would buy again.
Date published: 2024-11-13
Rated 5 out of
5
by
Bob H from
As expected....
Great product with on-time delivery! Product performed as expected...
Date published: 2024-06-03
Rated 5 out of
5
by
Phillip S from
I need every thermocouple from Omega!
easily my favorite piece of equipment in my toolbox.
Date published: 2023-11-27
Rated 5 out of
5
by
Adam R from
Quality product
Shipped on time and work perfect for our application
Date published: 2023-11-24
Rated 5 out of
5
by
Anonymous from
Core part of our diesel engine testing operations
Showed up as advertised, looking forward to replenishing our kit with these new cables. We ordered (and use) the 5 ft long option.
Date published: 2023-03-08
Rated 5 out of
5
by
Jcasady from
Quick delivery
The TC coiled extension 5 ft has worked well for our needs
Date published: 2022-10-17
Do these come with a certification of calibration?
Hi Tristan,
The order would ship with Cal-1 certification. This covers all items on the order. Cal-1 is emailed with the order confirmation. Cal-1 is a statement that all items on an order will meet or exceed the advertised specifications.
Best regards
OMEGA
Date published: 2021-10-20