Welcome to our new website, found an issue or bug? Please report it here
DRSL-TEMP

Choose a Variant
Input Type
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $184.75 |
5-9 | $175.51 |
10-24 | $171.82 |
25-49 | $164.43 |
50-99 | $160.73 |
100+ | $157.04 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy Note | Thermocouple Input: Better than 0.5°C or ±0.05% of span (selected input range) RTD Input: Better than 0.1°C or ±0.05% of span (selected input range) |
Approvals | CE, UL, RoHS |
Calibration Temperature, Max | 28 °C |
Calibration Temperature, Min | 20 °C |
EMC Immunity Note | NAMUR NE 21, A Criterion, Burst: <±1% of span (span = selected input range) |
EMC Standard | NAMUR NE 21 |
Electrical Output | 4 to 20 mA |
Enclosure Ratings | IP20 |
Height | 113 mm |
Input Range Note | THERMOCOUPLE INPUT ;Sensor and Cable Specifications:5 kΩ per wire;Cold Junction Compensation (CJC): Internal or external (selectable); CJC Accuracy via External CJC (Pt100 RTD Sensor): Better than ±0.15°C; CJC via Internally Mounted Sensor: Better than ±2.5°C;Open Thermocouple Detection: Yes (DIP switch selectable upscale or downscale);Pt100 RTD INPUT;Sensor Current, RTD: <150 µA;Sensor Cable Specifications:50 Ω per wire;Effect of Sensor Cable Resistance (3 or 4-Wire RTD): <0.002 Ω/Ω;Broken Sensor Detection: >800 Ω;Shorted Sensor Detection: <18 Ω |
Input Type | Thermocouple, RTD |
Installation | Pollution degree 2 and measurement/overvoltage category II |
Isolation | 300 Vac |
Length | 115 mm |
Load Resistance | Resistance: ≤(Vsupply - 5.5)/0.023 |
Mounting | DIN Rail 35 mm Standard, EN 60715 |
Noise Calibration | >60 dB |
Number of Inputs | 2 |
Operating Temperature, Max | 70 °C |
Operating Temperature, Min | -25 °C |
Output Detail | Programmable Signal Ranges:0 to 20 mA and 4 to 20 mA Range Limits (NAMUR NE43 Out of Range): Below 3.8 mA or above 20.5 mA Sensor Error Detection(Dip Switch Selectable forEnable or None): Below 3.5 mA or above 23 mA Incorrect DIP-Switch Setting Identification: Below 3.5 mA Output Error Level: DIP switch selectable for upscale or downscale |
Output Signal | Current |
Output Value | Process |
Power Consumption | 0.7 W |
RTD Accuracy | ± 0.05 % |
Relative Humidity | 0 to 95% RH (non-condensing) |
Response Time | < 30 ms |
Response Time Note | Response Time (0 to 90%, 100 to 10%): <30 ms/300 ms (selectable, provides either fast response or signal dampening as needed) |
Screw Terminal Torque | 0.5 Nm |
Stability | Load Stability: ≤0.01% of span/100 Ω |
Storage Temperature, Max | 85 °C |
Storage Temperature, Min | -40 °C |
Supply Power Type | DC |
Supply Voltage | 5.5 to 35 Vdc |
Temperature Coefficient | Thermocouple : ≤±0.1°C/°C or ≤±0.01%/°C; RTD : ≤±0.02 °C/°C |
Temperature Measurement Range | J: -100 to 1200°C, K: -180 to 1372°C, Pt100: -200 to 850°C |
Thermocouple Accuracy | ± 0.05 % |
Voltage Loss | 5.5 Vdc |
Weight | 70 g |
Width | 6.1 mm |
Wire Code Option | 2 -, 3 - , 4- Wire |
Wire Gauge | 26 to 12 AWG |
See All Specs |