Metric, High Accuracy, Load Washers to Measure Bolt Compression

  • 5 Point NIST Traceable Calibration Provided
  • Ranges to 200 kN
  • Compact Design
  • Spherical Washers Included
LCMWD
From $ 716.46
Metric, High Accuracy, Load Washers to Measure Bolt Compression LCMWD LCMWD
loading all models
Product Overview
  • Cable Length 5 ft
  • Calibration Option 5 POINT NIST
  • Electrical Connection Cable
  • Force Type Compression
  • Full Scale Deflection 0.001 in
  • Load Cell Type Load Washer
  • Materials Stainless Steel
  • Operating Temperature, Max 127 °C
  • Operating Temperature, Min -40 °C
  • Overload, Max 200% FS
  • Process Temperature, Max 71 °C
  • Process Temperature, Min 16 °C
  • Safe Overload 120% FS
  • Supply Power Note 10 Vdc, 15 Vdc maximum
  • Supply Voltage 10 Vdc
  • Thermal Span Effect ± 0.018% FSO/°C
  • Thermal Zero Effect ± 0.018% FSO/°C
  • Wiring/Connector Table Red: (+) Excitation; Black: (-) Excitation; Green: (+) Output; White: (-) Output
  • Zero/Balance Error ± 4%
The LCMWD is also available in standard configurations, with 0-200 to 0-200,000 lb ranges. Please see the LCWD for complete details, or contact our Pressure department for more information.


SPECIFICATIONS
Excitation: 10 Vdc (15V max)
Output: 2 mV/V
Accuracy (Linearity and Repeatability Combined):
?10K lb/50 kN: ± 0.5% BFSL
>10K lb/50 kN: ± 0.75% BFSL
Zero Balance: ± 4.0% FSO
Operating Temp Range: -40 to 127°C (-40 to 260°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ± 0.018% FSO/°C
Span: ± 0.018% FSO/°C
Safe Overload: 120% of capacity
Ultimate Overload: 200% of capacity
Bridge Resistance:
<50k lb/200 kN: 350 ? min
?50k lb/200 kN: 700 ?
Full Scale Deflection: 0.025 mm (0.001") typical
Construction: Stainless steel
Electrical: 1.5 m (5') insulated shielded cable
Rated 5 out of 5 by from Load Cell joint testing They worked as intended for our test requirements.
Date published: 2025-01-03
  • y_2025, m_2, d_21, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_LCMWD-100KN, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 35ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration